Douglas Barreto

Dr. Douglas Barreto

Civil Engineering, Federal University of São Carlos, São Carlos, São Paulo, Brazil
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
DMDébora Thomé Miranda
Débora Thomé Miranda
Douglas BarretoDouglas Barreto
Douglas Barreto
Inês Flores-ColenInês Flores-Colen
Inês Flores-Colen
The energy performance of buildings has been extensively studied at the Federal University of São Carlos, Brazil in order to achieve energy conservation and reduce environmental impacts. Artificial lighting is one of the systems that consume the most electricity in educational buildings; therefore, by adopting measures to improve energy performance, the luminous performance can also be improved. Artificial lighting allows for visual tasks to be accurately and safely carried out by means of lamps of varied temperatures, color rendering index, and luminous performance. Providing adequate lighting in school environments can influence both the health and well-being of school members, contributing positively to productivity. The present study aimed to evaluate the luminous performance of the existing artificial lighting system in a classroom by considering the minimum requirements recommended by the Brazilian standard NBR ISO/CIE 8995-1/2013. Through computer simulations using the DIALux evo program, it was possible to propose actions to improve the existing lighting system in order to offer better visual comfort to users and ensure electricity savings. The artificial lighting system consisted of LED luminaires integrated with daylight and the use of a manual control device, thus generating electricity savings of almost 65% when compared with the existing artificial lighting system in the room.

1 April 2023 in Ambiente Construído
Verified
Journal Article
Open access
PDF file
EAEllon Bernardes de Assis
Ellon Bernardes de Assis
Douglas BarretoDouglas Barreto
Douglas Barreto
JNJorge Munaiar Neto
Jorge Munaiar Neto
Resumo Escadas pré-moldadas leves de concreto podem ser fixadas na alvenaria com chumbadores metálicos, cuja estabilidade depende da integridade dos pontos de ancoragem. O ambiente em que está fixada a escada tem papel vital na desocupação de um edifício em situação de incêndio, o que justifica estudar o comportamento desses elementos durante um incêndio. Este trabalho apresenta estratégia numérica para realizar simulações com o código computacional ABAQUS com vistas a melhor entender o comportamento de escadas pré-moldadas e seu sistema de ancoragem em alvenaria estrutural de blocos de concreto em ambiente sob incêndio. A evolução da temperatura foi determinada nos pontos de ancoragem e na viga denteada da escada em resposta ao incêndio-padrão ISO 834-1:1999 apenas na face oposta à parede em que a escada está fixada. Os resultados mostram que as elevações de temperatura no chumbador e na viga denteada não atingem níveis que reduzam significativamente a resistência do aço, quando a cavidade do bloco está grauteada, e da resistência do concreto respectivamente. Tais resultados sinalizam aspectos importantes em contexto construtivo de sistemas de alvenaria estrutural e segurança ao incêndio.

1 August 2016 in Revista FLAMMAE
Verified
Journal Article
Closed access
CNCaio C. de O. Nunes
Caio C. de O. Nunes
Douglas BarretoDouglas Barreto
Douglas Barreto
O sistema de combate a incêndio por hidrantes trata-se de dispositivos instalados nas edificações que auxiliam na extinção de incêndios, mas para que isto ocorra os mesmos devem ser conservados adequadamente ao longo da ocupação dos edifícios. Objeto de estudo deste trabalho foi a primeira fase do conjunto habitacional “Médico Luiz Spina” no município de Barretos – SP com um total de 420 unidades habitacionais.

3 November 2023 in Acta Scientiarum. Technology
Verified
Journal Article
Open access
PDF file
DMDébora Thomé Miranda
Débora Thomé Miranda
Douglas BarretoDouglas Barreto
Douglas Barreto
GPGuilherme Aris Parsekian
Guilherme Aris Parsekian
ANAry Rodrigues Alves Netto
Ary Rodrigues Alves Netto
Lighting is one of the systems that mostly consume electricity in commercial buildings. Therefore, improving its efficiency has the potential to reduce electricity consumption and emission of polluting gases. The objective of the present study was to assess an office lighting system retrofit of an existing building from the 1990s, verify the light levels in relation to standards of the Brazilian requirements, and to explore new systems with potential for luminous and energy improvement. The analyzes were carried out through computer simulations using the DIALux evo software, which allows the evaluation of artificial and natural illuminations simultaneously. The results indicated that the existing lighting system does not meet the average illuminance standard value for office environment. From simulations with new arrangements and types of luminaires and lamps, two more efficient lighting systems were designed. The first presented savings of 15.5% in lighting energy when replacing T12 fluorescent lamps with LED luminaires. The second system considered the use of natural light and was complemented by artificial lighting with the aid of a dimming system linked to the availability of daylight, and presented up to 67% less electric energy consumption when compared to the existing lighting system in the environments. Therefore, it was possible to propose actions to the existing lighting system retrofit and, thus, offer better visual comfort to users and at the same time save energy.

28 August 2024 in Revista Latino-americana de Ambiente Construído & Sustentabilidade
Verified
Journal Article
Open access
PDF file
VTVitor Vieira Tomioka
Vitor Vieira Tomioka
Douglas BarretoDouglas Barreto
Douglas Barreto
El estudio investiga el potencial de los techos verdes como elemento de contribución a la sostenibilidad urbana, mediante un análisis del panorama de las legislaciones internacionales y nacionales vigentes, y utilizando criterios comunes encontrados para la aplicación en el estudio de caso del potencial de implementación de techos verdes en Brás, un barrio de la región central de la ciudad de São Paulo. La primera etapa consistió en una revisión legislativa de Brasil y de países desarrollados en el tema de techos verdes, demostrando la disparidad existente, y sugiere que un enfoque híbrido, combinando políticas obligatorias para nuevas construcciones e incentivos para construcciones existentes, puede ser la clave para una adopción generalizada y eficaz de techos verdes. Finalmente, se realizaron simulaciones de criterios definidos a partir de la revisión legislativa, buscando entender cuáles de ellos presentan mayor potencial de adopción de acuerdo con el contexto de las construcciones. Por ejemplo, el criterio 2 (construcciones con más de 2,000 m² de área) presentó un área potencial de aplicación de techos verdes 23% menor que el criterio 1 (edificios con 4 pisos o más), pero abarca 94% menos lotes, haciendo que la supervisión pública sea menos onerosa. Así, este enfoque equilibrado considera las complejidades del desarrollo urbano, reconociendo la necesidad de diferentes estrategias para lograr un entorno construido más sostenible.

16 November 2021 in SimpÓsio Nacional de Sistemas Prediais
Verified
Conference Paper
Closed access
PDF file
TFTaciane Roberta Franceacatto
Taciane Roberta Franceacatto
Douglas BarretoDouglas Barreto
Douglas Barreto
RESUMO: As edificações destinadas aos Hotéis, além de alvenaria tradicional, também utilizam o sistema de gesso acartonado para a compartimentação interna de seus ambientes, inclusive para as divisórias internas para os banheiros dos quartos. No entanto, este componente é sensível à ação da água, sendo necessário maior atenção nestes ambientes com alto índice de umidade. Deste modo, esta pesquisa teve como objetivo identificação e análise das manifestações patológicas que ocorrem em banheiros de edifícios hotéis construídos com paredes de alvenaria e gesso acartonado. Para identificação dessas manifestações foi realizada uma pesquisa documental, a partir da análise de registros de ocorrências diárias, em uma amostra de três hotéis, sendo as informações fornecidas pelo setor de manutenção dos hotéis, que estão localizados em Araraquara e Ribeirão Preto, no estado de São Paulo. Entre as constatações, verificou-se que os locais onde se encontram as instalações hidrossanitárias foram os mais problemáticos, com 80% dos registros, dos quais, 48% referem-se aos problemas de desprendimento de objetos das paredes. A pesquisa identificou um conjunto de manifestações patológicas, com suas características e influências nos sistemas de gesso acartonado e de alvenaria, apontando as manifestações patológicas que ocorrem em edificações hoteleiras.