Alka Rani Batra

Mrs. Alka Rani Batra


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in International Journal of Food Microbiology
Verified
Journal Article
Closed access
ABAlka Rani Batra
Alka Rani Batra
VRVivek B. Ravindran
Vivek B. Ravindran
ASAravind Surapaneni
Aravind Surapaneni
NMNitin Mantri
Nitin Mantri
ABAndrew S. Ball
Andrew S. Ball

21 January 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ABAlka Rani Batra
Alka Rani Batra
VRVivek B. Ravindran
Vivek B. Ravindran
ASAravind Surapaneni
Aravind Surapaneni
ESEsmaeil Shahsavari
Esmaeil Shahsavari
NHNagalakshmi Haleyur
Nagalakshmi Haleyur
ABAndrew S. Ball
Andrew S. Ball
Shiga toxin-producing Escherichia coli serotype O157:H7 is a food and waterborne zoonotic pathogen causing gastroenteritis in humans. Rapid and simple detection in water and food is imperative to control its spread. However, traditional microbial detection approaches are time-consuming, expensive and complex to operate at the point-of-care without professional training. We present a rapid, simple, sensitive, specific and portable method for detection of E. coli O157:H7 in drinking water, apple juice and milk. We evaluated the effect of gene selection in detecting E. coli O157:H7 using recombinase polymerase amplification coupled with a lateral flow assay using rfbE, fliC and stx gene targets. As low as 100 ag and 1 fg DNA, 4–5 CFU/mL and 101 CFU/mL of E. coli O157:H7 was detected using the stx and rfbE gene targets respectively with 100% specificity, whilst the detection limit was 10 fg DNA and 102 CFU/mL for the fliC gene target, with 72.8% specificity. The RPA-LFA can be completed within 8 min at temperatures between 37 and 42 °C with reduced handling and simple equipment requirements. The test threshold amplification of the target was achieved in 5–30 min of incubation. In conclusion, RPA-LFA represents a potential rapid and effective alternative to conventional methods for the monitoring of E. coli O157:H7 in food and water.

14 October 2022 in Foods
Verified
Journal Article
Open access
PDF file
ABAlka Rani Batra
Alka Rani Batra
CDCharles Chinyere Dike
Charles Chinyere Dike
NMNitin Mantri
Nitin Mantri
ABAndy Ball
Andy Ball
The detection of both viable and viable but non-culturable (VBNC) Escherichia coli O157:H7 is a crucial part of food safety. Traditional culture-dependent methods are lengthy, expensive, laborious, and unable to detect VBNC. Hence, there is a need to develop a rapid, simple, and cost-effective detection method to differentiate between viable/dead E. coli O157:H7 and detect VBNC cells. In this work, recombinase polymerase amplification (RPA) was developed for the detection of viable E. coli O157:H7 through integration with propidium monoazide (PMAxx). Initially, two primer sets, targeting two different genes (rfbE and stx) were selected, and DNA amplification by RPA combined with PMAxx treatment and the lateral flow assay (LFA) was carried out. Subsequently, the rfbE gene target was found to be more effective in inhibiting the amplification from dead cells and detecting only viable E. coli O157:H7. The assay’s detection limit was found to be 102 CFU/mL for VBNC E. coli O157:H7 when applied to spiked commercial beverages including milk, apple juice, and drinking water. pH values from 3 to 11 showed no significant effect on the efficacy of the assay. The PMAxx-RPA-LFA was completed at 39 °C within 40 min. This study introduces a rapid, robust, reliable, and reproducible method for detecting viable bacterial counts. In conclusion, the optimised assay has the potential to be used by the food and beverage industry in quality assurance related to E. coli O157:H7.

2 February 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
ABAlka Rani Batra
Alka Rani Batra
DCDarren Cottam
Darren Cottam
MLMuriel Lepesteur-Thompson
Muriel Lepesteur-Thompson
CDCarina Dexter
Carina Dexter
KZKelly Zuccala
Kelly Zuccala
SSSarvesh Soni
Sarvesh Soni
Waterborne diseases are known as a leading cause of illness and death in both developing and developed countries. Several pathogens can be present in contaminated water, particularly waters containing faecal material; however, routine monitoring of all pathogens is not currently possible. Enterococcus faecalis, which is present in the microflora of human and animals has been used as a faecal indicator in water due to its abundance in surface water and soil. Accurate and fast detection methods are critical for the effective monitoring of E. faecalis in the environment. Although conventional and current molecular detection techniques provide sufficient sensitivity, specificity and throughput, their use is hampered by the long waiting period (1–6 days) to obtain results, the need for expensive laboratory equipment, skilled personnel, and cold-chain storage. Therefore, this study aimed to develop a detection system for E. faecalis that would be simple, rapid, and low-cost, using an isothermal DNA amplification assay called recombinase polymerase amplification (RPA), integrated with a lateral flow assay (LFA). The assay was found to be 100% selective for E. faecalis and capable of detecting rates as low as 2.8 × 103 cells per 100 mL from water and wastewater, and 2.8 × 104 cells per 100 mL from saline water. The assay was completed in approximately 30 min using one constant temperature (38 °C). In addition, this study demonstrated the quantitation of E. faecalis using a lateral flow strip reader for the first time, enhancing the potential use of RPA assay for the enumeration of E. faecalis in wastewater and heavily contaminated environmental waters, surface water, and wastewater. However, the sensitivity of the RPA-LFA assay for the detection of E. faecalis in tap water, saline water and in wastewater was 10–1000 times lower than that of the Enterolert-E test, depending on the water quality. Nevertheless, with further improvements, this low-cost RPA-LFA may be suitable to be used at the point-of-need (PON) if conjugated with a rapid field-deployable DNA extraction method.