Jean-Baptiste Sanchez

Dr. Jean-Baptiste Sanchez

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
AMAchraf El Mohajir
Achraf El Mohajir
JCJimena Castro-Gutiérrez
Jimena Castro-Gutiérrez
RCRafael Luan Sehn Canevesi
Rafael Luan Sehn Canevesi
IBIgor Bezverkhyy
Igor Bezverkhyy
GWGuy Weber
Guy Weber
JSJean-Baptiste Sanchez
Jean-Baptiste Sanchez

17 October 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
AMAchraf EL MOHAJIR
Achraf EL MOHAJIR
MAMohammad Arab-Pour-Yazdi
Mohammad Arab-Pour-Yazdi
AKAnna Krystianiak
Anna Krystianiak
OHOlivier Heintz
Olivier Heintz
Nicolas MARTINNicolas MARTIN
Nicolas MARTIN
JSJean-Baptiste Sanchez
Jean-Baptiste Sanchez
SnO2 thin films were prepared by conventional and Glancing Angle Deposition reactive sputtering, and their gas sensing properties were investigated. The porosity of the as-prepared films was widely assessed using optical methods, and the sensing performances of these active layers were correlated with the evolution of surface and film porosity as a function of deposition conditions and annealing treatment. The sensor made of inclined columns grown at high sputtering pressure (6 × 10−3 mbar) and annealed at 500 °C in air exhibited the best response to benzene, with a limit of detection of 30 ppb. In addition, successful BTEX (i.e., benzene, toluene, ethylbenzene, and xylenes) discrimination was achieved by combining the sensing signals of four nanostructured tin-oxide-based gas sensors.

1 November 2010 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
JSJean-Baptiste Sanchez
Jean-Baptiste Sanchez
ASAline Schmitt
Aline Schmitt
FBFranck Berger
Franck Berger
CMChristophe Mavon
Christophe Mavon
We report the fabrication of a gas chromatographic column module integrated on a silicon substrate and usable as a portable measurement device dedicated to the selective detection of various chemical compounds (gas or vapour). PDMS, PEG, and F13-TEOS stationary phases have been prepared in order to coat the inside walls of microchannels. The microcolumn tests were performed with a mixture of hydrocarbons and ketone. After having evaluated the effectiveness of such a separation module, we showed an application by coupling a GC microcolumn with a metal oxide-based gas sensor. The best results were obtained at a low isothermal temperature mode of the GC micro-column (near the ambient temperature). The coupling between the GC microcolumn and a metal oxide gas sensor enables to obtain a rapid, reliable, and selective analysis of various chemical compounds.

1 January 2020 in Materials Today: Proceedings
Verified
Journal Article
Closed access
RLRadouane Leghrib
Radouane Leghrib
YAYassine Aantri
Yassine Aantri
JSJean-Baptiste Sanchez
Jean-Baptiste Sanchez
FBFranck Berger
Franck Berger
AKAbderrazak Kaaya
Abderrazak Kaaya

6 July 2024 in Materials Letters
Verified
Journal Article
Closed access
JSJean-Baptiste Sanchez
Jean-Baptiste Sanchez
AKAnna Krystianiak
Anna Krystianiak
EDEmmanuel Dordor
Emmanuel Dordor
OHOlivier Heintz
Olivier Heintz
NGNicolas Geoffroy
Nicolas Geoffroy
Nicolas MARTINNicolas MARTIN
Nicolas MARTIN

1 November 2015 in Sensor Letters
Verified
Journal Article
Closed access
JSJean-Baptiste Sanchez
Jean-Baptiste Sanchez
HLH. Lahlou
H. Lahlou
YMYehya Mohsen
Yehya Mohsen
AGA. Gaddari
A. Gaddari
FBF. Berger
F. Berger
This study deals with the development of a microfabricated detection system able to concentrate and detect ammonia. An activated carbon was used as the adsorbent material in the microfabricated gas preconcentrator. The sol–gel process used to synthesize SnO2 sensitive surface allowed to detect ammonia at room temperature. The variation of the relative conductance of the system versus time for different ammonia concentrations was studied. Thanks to the use of the preconcentration stage, the detection limit of the system was 250 ppb.