Aftab Ahmed Ansari

Aftab Ahmed Ansari

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
AAAftab Ahmed Ansari
Aftab Ahmed Ansari
GDGiribabu Dyanamina
Giribabu Dyanamina
In present electrical power systems, wind energy conversion systems based on doubly fed induction generators represent one of the most commonly accepted systems in the global market due to their excellent performance under different power system operations. The high wind energy penetration rate makes it challenging for these wind turbines to follow grid code requirements. All operations of a wind energy system during a dip in voltage require special attention; these operations are critically known as fault ride-through and low voltage ride-through. In this paper, various fault ride-through techniques of doubly fed induction generator-based wind energy conversion systems, such as protective circuitry, reactive power injection, and control methods for transient and steady state operations, have been presented to improve the performance. During system disturbances, protective circuitry or control mechanisms are typically used to limit the over-current of the rotor and the generated inappropriate DC link over-voltage. Simultaneously, the reactive power injection system overcomes the reactive power scarcity and enhances the transient response, further limiting the DC bus voltage and rotor current. This review paper compares and suggests appropriate FRT methods that are driven by external modifications and internal system improvements. Furthermore, typical case studies are discussed to illustrate and support the FRT system. The impact of each case study was evaluated and analyzed using the results obtained from the MATLAB/Simulink application and the OPAL-RT (OP4500) real time simulator (RTS).

12 December 2023 in IET Electric Power Applications
Verified
Journal Article
Open access
TSTanmay Shukla
Tanmay Shukla
MBMirza Jawad Baig
Mirza Jawad Baig
KAKaushal Kishor Ahirwar
Kaushal Kishor Ahirwar
ARAnchal Raghuwanshi
Anchal Raghuwanshi
AAAftab Ahmed Ansari
Aftab Ahmed Ansari
AAApsara Adhikari
Apsara Adhikari
An approach is presented to employ two different types of converters in bridgeless configuration for supply side power factor enhancement of the system. The isolated single‐stage electric vehicle battery charger uses two different converters in a bridgeless configuration to extract the advantages of both converters for supply‐side power factor enhancement. For the negative and positive semi‐cycles of the supply voltage, the power factor‐enhanced asymmetrical alternating current–direct current converter utilises a fourth order single‐ended primary‐inductor converter and a second order buck‐boost converter, respectively. The use of single‐ended primary‐inductor converter and buck‐boost converter in bridgeless configuration reduces the net order of the system with respect to conventional bridgeless‐single‐ended primary‐inductor converter schemes. The buck‐boost converter also needs the supply‐side filter to eradicate the unwanted harmonics in the supply current which increases the order of the system. The usage of both converters presents many benefits like input inductance of the single‐ended primary‐inductor converter can be utilised as a filtering element with a capacitor for the buck‐boost converter. The anti‐parallel diode conduction operation of both switches facilitates the elimination of extra reverse feed diodes (generally used in bridgeless schemes). The single‐stage charger itself comes with the benefit of elimination of extra stages and thus the losses associated with it. The presented charger also witnesses the elimination of the rectifier due to usage of bridgeless configuration. The isolated single‐stage electric vehicle battery charger is also garnished with electrical isolation which adds to the safety standard of the system. To attain power factor enhancement, the asymmetrical alternating current–direct current converter functions in discontinuous current conduction mode in the present work. The elimination of extra‐stages (with respect to two stage charger), a filter, a rectifier, two extra reverse‐feeding diodes, one voltage sensor, one current sensor (with respect to continuous current conduction mode), and electrical isolation not only makes the system compact and safer but also makes the system cheaper. Elaborated mathematical modelling and stability analysis of the presented alternating current–direct current converter using a pole‐zero map and bode plot have been included in the article. The prototype and MATLAB/Simulink model of isolated single‐stage electric vehicle battery charger system with discontinuous current conduction mode control has been built and results of both prototype and MATLAB/Simulink are deployed to verify isolated single‐stage electric vehicle battery charger system's performance during dynamic and steady‐state conditions.