Tanmay Shukla

Mr. Tanmay Shukla

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
TSTanmay Shukla
Tanmay Shukla
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
This article presents a brushless DC motor drive using a solar photovoltaic (PV) array and grid. Solar PV array-fed drive systems typically need a DC–DC converter stage in order to optimize the solar PV array-generated power utilizing a maximum power point (MPP) tracking technique. In this work, a boost DC–DC converter is used for MPP tracking purposes. This work utilizes an incremental conductance (INC) MPP-tracking algorithm. A bridgeless asymmetrical converter without a bridge rectifier is used at the grid side to improve power quality at supply mains. The presented asymmetrical converter is an amalgamation of a second order (buck boost) with a fourth-order (Cuk) converter, which lowers the net system’s order. The input inductor of the Cuk converter manages the input current profile and, thus, eradicates the need for the filter at the grid mains. The bridgeless asymmetrical converter comes with several advantages, such as rectifier removal, component reduction, and input filter elimination. The performance of the brushless DC motor is examined in this article in all three scenarios: first, when grid and solar energy are both present; second, when solar energy is the only source of energy; and third, when grid energy is the only source of energy. The dual-source-based brushless DC motor drive system has been developed on matrix-laboratory/Simulink. The results are deployed and discussed to verify the drive-system performance. The article also presents a detailed stability analysis and mathematical modeling of the presented power-quality converter and MPP tracking converter to verify different converters’ stability using a bode diagram and a pole-zero plot.

10 August 2023 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
TSTanmay Shukla
Tanmay Shukla
NPNarayan Prasad Patidar
Narayan Prasad Patidar
AAApsara Adhikari
Apsara Adhikari
This article presents a power factor profile-improved bridgeless buckboost-Cuk converter-fed battery charging system for electric vehicle applications. The conventional charging system does not use any power factor improvement stage, due to which the supply current harmonics are very high and violate IEC-61000-3-2 standard guidelines. To meet the international standard guidelines, a compact and efficient power factor-improved converter stage is necessary. The power factor-improved converter in the present work uses a fourth-order Cuk converter during negative semi-cycle and a second-order buckboost converter during positive semi-cycles of the supply voltage. The amalgamation of a second- and fourth-order converter in a bridgeless configuration reduces the systems order concerning a bridgeless Cuk converter-based system and also eradicates the need for a diode-based bridge rectifier (DbBR). Due to the presence of an input side inductor, there is no requirement for an external filter like a bridgeless buckboost converter-based scheme. The input inductor in the present scheme performs twin action; it reduces harmonic disturbances in the mains current during the negative semi-cycle and also works with capacitor CP to filter harmonics and improve the mains current profile during the positive semi-cycle of the mains voltage. The power factor-improved converter in the present work is operated in discontinuous conduction mode (DCM). This eliminates the requirement for extra sensors compared to continuous conduction mode (CCM). The scheme also eliminates the need for two extra back-feed diodes which are generally required in bridgeless configuration loop completion during different semi-cycles of mains voltage. In the present scheme, the work of back-feed diodes is done by the anti-parallel inherent diodes of the switches. In the second stage, a high-frequency-operated flyback converter is used which not only boosts the battery current profile but also provides the electrical isolation between the supply side and load. This article also presents the detailed stability analysis and math modeling of the presented bridgeless buckboost-Cuk converter. The presented system is built on MATLAB/Simulink, and results are presented and discussed to validate the system performance.

1 June 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
TSTanmay Shukla
Tanmay Shukla
UKUjjwal Kumar Kalla
Ujjwal Kumar Kalla
This article presents a BLDC (permanent magnet brushless DC) motor drive for marine electric vehicle (MEV) application. The presented scheme uses bridgeless canonical cell (BL-CC) converter with center-tapped inductor (shown as two separate inductors for analysis purpose) for source-side power factor correction (PFC); however, the BL-CC converter requires two inductors. In the presented scheme use of one center-tapped inductor eliminates the requirement of one extra inductor. Thus, center-tapped inductor usage in BLDC motor drive results in decrement in components count. The BL-CC converter-based BLDC motor drive scheme do not require extra back-feeding diodes like other bridgeless (BL) schemes, but it uses inbuilt antiparallel diodes of insulated gate bipolar transistor (IGBT) switches for the same purpose this again leads to decrement in required component count. In this work, PFC BL-CC converter is operated in discontinuous inductor current (DIC) mode to attain better power quality. The DIC mode operation requires only one voltage sensor to sense DC-link voltage, whereas in continuous conduction mode (CCM), the sensor requirement increases to three (two voltage sensors and one current sensor). The PFC BL-CC converter also eliminates the diode bridge rectifier stage. The elimination of one extra inductor, two extra back-feeding diodes, DBR stage and also requirement of only one voltage sensor in DIC mode operation instead of three sensors for CCM implies reduction in components count which implies the reduction in cost and also the volume and weight of the BLDC motor drive. The weight reduction for marine (on-board) electric vehicle is very important as this enhances the vehicle performance. This paper also presents the detailed mathematical modeling and stability analysis of presented BL-CC converter using pole zero map and Bode plot. The BL-CC converter-based BLDC motor driving system for MEV application for DIC mode operation has been developed in the laboratory as well as on MATLAB/Simulink platform and simulated MATLAB and real-time experimental results have been presented to validate the presented BLDC motor drive under steady-state and dynamic operating conditions.

12 December 2023 in IET Electric Power Applications
Verified
Journal Article
Open access
TSTanmay Shukla
Tanmay Shukla
MBMirza Jawad Baig
Mirza Jawad Baig
KAKaushal Kishor Ahirwar
Kaushal Kishor Ahirwar
ARAnchal Raghuwanshi
Anchal Raghuwanshi
AAAftab Ahmed Ansari
Aftab Ahmed Ansari
AAApsara Adhikari
Apsara Adhikari
An approach is presented to employ two different types of converters in bridgeless configuration for supply side power factor enhancement of the system. The isolated single‐stage electric vehicle battery charger uses two different converters in a bridgeless configuration to extract the advantages of both converters for supply‐side power factor enhancement. For the negative and positive semi‐cycles of the supply voltage, the power factor‐enhanced asymmetrical alternating current–direct current converter utilises a fourth order single‐ended primary‐inductor converter and a second order buck‐boost converter, respectively. The use of single‐ended primary‐inductor converter and buck‐boost converter in bridgeless configuration reduces the net order of the system with respect to conventional bridgeless‐single‐ended primary‐inductor converter schemes. The buck‐boost converter also needs the supply‐side filter to eradicate the unwanted harmonics in the supply current which increases the order of the system. The usage of both converters presents many benefits like input inductance of the single‐ended primary‐inductor converter can be utilised as a filtering element with a capacitor for the buck‐boost converter. The anti‐parallel diode conduction operation of both switches facilitates the elimination of extra reverse feed diodes (generally used in bridgeless schemes). The single‐stage charger itself comes with the benefit of elimination of extra stages and thus the losses associated with it. The presented charger also witnesses the elimination of the rectifier due to usage of bridgeless configuration. The isolated single‐stage electric vehicle battery charger is also garnished with electrical isolation which adds to the safety standard of the system. To attain power factor enhancement, the asymmetrical alternating current–direct current converter functions in discontinuous current conduction mode in the present work. The elimination of extra‐stages (with respect to two stage charger), a filter, a rectifier, two extra reverse‐feeding diodes, one voltage sensor, one current sensor (with respect to continuous current conduction mode), and electrical isolation not only makes the system compact and safer but also makes the system cheaper. Elaborated mathematical modelling and stability analysis of the presented alternating current–direct current converter using a pole‐zero map and bode plot have been included in the article. The prototype and MATLAB/Simulink model of isolated single‐stage electric vehicle battery charger system with discontinuous current conduction mode control has been built and results of both prototype and MATLAB/Simulink are deployed to verify isolated single‐stage electric vehicle battery charger system's performance during dynamic and steady‐state conditions.

27 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
TSTanmay Shukla
Tanmay Shukla
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
This article presents a brushless DC motor (BLDCM) drive for a maritime electric vehicle (MEV) application. The presented BLDCM drive uses a bridgeless Cuk-buckboost (BL-Cuk-BB) converter for input-side power factor (PF) improvement. The BL-Cuk-BB converter uses the buckboost converter for the negative half-cycles of the input AC voltages and the Cuk converter for the positive half-cycles. In the case of MEVs, the drive systems are generally fed by diesel engine generators (DEGs). The asymmetric BL-Cuk-BB converter is operated in a discontinuous inductor current mode (DICM) in the present work to attain better power quality. The usage of a second-order buckboost converter with a fourth-order Cuk converter results in a decrement in the net order of the system. Additionally, the input inductor of the Cuk converter also participates as the filter component along with capacitor C2 during buckboost converter operation to enhance the power quality. The total component count reduction in the BL-Cuk-BB converter is also achieved by eliminating the usage of extra/external back-feeding diodes, which are generally used in bridgeless schemes. The present scheme uses the inbuilt anti-parallel diodes for the same purpose. The lesser components requirement in the BL-Cuk-BB-converter-based BLDCM drive implies lesser cost and volume, along with greater reliability, lower conduction losses, and lower weight of the BLDCM drive, which adds to the merits of the model. The paper includes a detailed mathematical model and stability analysis using pole-zero maps and bode plots of the BL-Cuk-BB converter for each half-supply AC voltage cycle. The BL-Cuk-BB-converter-based BLDCM drive for an EV application has been developed on the MATLAB/Simulink platform for a DICM operation, and the MATLAB simulation results have been presented for validation of the BL-Cuk-BB-converter-based BLDCM drive.

1 January 2024 in IET Circuits, Devices & Systems
Verified
Journal Article
Open access
SSShailu Sachan
Shailu Sachan
TSTanmay Shukla
Tanmay Shukla
PSPankaj Swarnkar
Pankaj Swarnkar
AAApsara Adhikari
Apsara Adhikari
Wireless communication network in robotic telesurgery can be a huge advantage to smart healthcare systems that allows the surgeon to perform surgery on remote patients utilizing a surgical robot. It enables the surgical robotic manipulator to replicate the natural hand motions of the surgeon, allowing it to carry out operations with greater acuity and dexterity. This paper addresses the development of an intelligent controller to assure the safe functioning of a telesurgical robotic manipulator. The intelligent optimized, adaptive, and learning‐based adaptive neuro‐fuzzy fractional order sliding mode control (ANFFOSMC) controller is proposed to attain dexterity and acuity of the surgical manipulator for surgical interventions. The proposed controller for telesurgical system exhibits superior accuracy and performance compared to conventional controllers, as evidenced by reduced root mean square error (RMSE), integral squared error (ISE), and integral absolute error (IAE). The performance of the robot is evaluated using performance indices in the occurrence of uncertainties and external disturbances.