Břetislav Mikel

Dr. Břetislav Mikel


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2012 in Sensors
Verified
Journal Article
Open access
PDF file
ZBZdenek Buchta
Zdenek Buchta
SRSimon Rerucha
Simon Rerucha
BMBřetislav Mikel
Břetislav Mikel
MČMartin Čížek
Martin Čížek
JLJosef Lazar
Josef Lazar
OCOndrej Cip
Ondrej Cip
In this paper, a novel principle of contactless gauge block calibration is presented. The principle of contactless gauge block calibration combines low-coherence interferometry and laser interferometry. An experimental setup combines Dowell interferometer and Michelson interferometer to ensure a gauge block length determination with direct traceability to the primary length standard. By monitoring both gauge block sides with a digital camera gauge block 3D surface measurements are possible too. The principle presented is protected by the Czech national patent No. 302948.

20 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MČMartin Čížek
Martin Čížek
VHVáclav Hucl
Václav Hucl
JHJan Hrabina
Jan Hrabina
RSRadek Smid
Radek Smid
BMBřetislav Mikel
Břetislav Mikel
OCOndrej Cip
Ondrej Cip
A passive optical resonator is a special sensor used for measurement of lengths on the nanometer and sub-nanometer scale. A stabilized optical frequency comb can provide an ultimate reference for measuring the wavelength of a tunable laser locked to the optical resonator. If we lock the repetition and offset frequencies of the comb to a high-grade radiofrequency (RF) oscillator its relative frequency stability is transferred from the RF to the optical frequency domain. Experiments in the field of precise length metrology of low-expansion materials are usually of long-term nature so it is required that the optical frequency comb stay in operation for an extended period of time. The optoelectronic closed-loop systems used for stabilization of combs are usually based on traditional analog electronic circuits processing signals from photodetectors. From an experimental point of view, these setups are very complicated and sensitive to ambient conditions, especially in the optical part, therefore maintaining long-time operation is not easy. The research presented in this paper deals with a novel approach based on digital signal processing and a software-defined radio. We describe digital signal processing algorithms intended for keeping the femtosecond optical comb in a long-time stable operation. This need arose during specialized experiments involving measurements of optical frequencies of tunable continuous-wave lasers. The resulting system is capable of keeping the comb in lock for an extensive period of time (8 days or more) with the relative stability better than 1.6 × 10−11.

12 January 2015 in Sensors
Verified
Journal Article
Open access
PDF file
RSRadek Smid
Radek Smid
MČMartin Čížek
Martin Čížek
BMBřetislav Mikel
Břetislav Mikel
OCOndrej Cip
Ondrej Cip
We present a method of noise suppression of laser diodes by an unbalanced Michelson fiber interferometer. The unstabilized laser source is represented by compact planar waveguide external cavity laser module, ORIONTM (Redfern Integrated Optics, Inc.), working at 1540.57 nm with a 1.5-kHz linewidth. We built up the unbalanced Michelson interferometer with a 2.09 km-long arm based on the standard telecommunication single-mode fiber (SMF-28) spool to suppress the frequency noise by the servo-loop control by 20 dB to 40 dB within the Fourier frequency range, remaining the tuning range of the laser frequency.

27 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MJMichal Jelínek
Michal Jelínek
OCOndrej Cip
Ondrej Cip
JLJosef Lazar
Josef Lazar
BMBřetislav Mikel
Břetislav Mikel
In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment’s protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics’ lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals.

6 September 2016 in Sensors
Verified
Journal Article
Open access
PDF file
RSRadek Smid
Radek Smid
MČMartin Čížek
Martin Čížek
BMBřetislav Mikel
Břetislav Mikel
JHJan Hrabina
Jan Hrabina
JLJosef Lazar
Josef Lazar
OCOndrej Cip
Ondrej Cip
The absolute distance between the mirrors of a Fabry-Perot cavity with a spacer from an ultra low expansion material was measured by an ultra wide tunable laser diode. The DFB laser diode working at 1542 nm with 1.5 MHz linewidth and 2 nm tuning range has been suppressed with an unbalanced heterodyne fiber interferometer. The frequency noise of laser has been suppressed by 40 dB across the Fourier frequency range 30–300 Hz and by 20 dB up to 4 kHz and the linewidth of the laser below 300 kHz. The relative resolution of the measurement was 10 − 9 that corresponds to 0.3 nm (sub-nm) for 0.178 m long cavity with ability of displacement measurement of 0.5 mm.

16 March 2007
Verified
Conference Paper
Closed access
BMBřetislav Mikel
Břetislav Mikel
RHRadek Helán
Radek Helán
OČOndřej Číp
Ondřej Číp
We simulated chirped and apodized fiber Bragg gratings (fiber gratings with modulation of the amplitude and with modulation of the spacing) the same as uniform fiber gratings. Results of our simulations are presented. Apodization of fiber Bragg gratings (FBG) has many advantages in comparison to other types of FBGs. Main improvement is suppressing of the side lobes in the grating spectral properties. The difference of side lobes suppression for uniform and Gaussian apodized grating is more than 110dB. On the basis of these results we designed a special fiber Bragg grating with apodization especially for using to stabilize semiconductor lasers for high precision laser applications with central wavelength 760nm. We present application of methods for calculation of parameters of apodized fiber Bragg gratings (FBG). We used combination of methods based on layered dielectric media (LDM) and the transfer matrix. On the contrary to the other calculation techniques the LDM method is based on sequence of thin films of dielectric media assembled in the direction of wave propagation. The combination of the LDM method and the transfer matrix method can be used to the calculation of arbitrary fiber gratings with high precision. For this designed apodized FBG we calculated the phase mask to manufacture by interference patterns. The phase mask and the fixation bottom of the fiber were made by e-beam lithography to achieve highly precise stability during manufacturing. We present the set-up of this system for writing FBG by pulsed UV laser with wavelength 266nm. Measurement of commercially available FBG with comparison to our calculated FBG is presented.