Aim: This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). Methods: 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. Results: The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (− 16.5 dB C/MHL) and in noise (− 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. Conclusions: The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient’s anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.
Administration of low-dose steroids via a catheter inserted into the cochlea to apply pharmaceuticals to more apical regions was previously shown not to be sufficient for long-term reduction of electrode impedances. The aim of the present study was to investigate the effect of intra-cochlear high-dose triamcinolone application on impedances in cochlear implant recipients. Patients received low-dose (4 mg/ml; n = 5) or high-dose (20 mg/ml; n = 5) triamcinolone via a cochlear catheter just prior to the insertion of a Med-El Flex28 electrode. Impedances were measured at defined time points from intra-operatively up to 12 months after first fitting and retrospectively compared with a control group (no steroid application). Patients who received a high-dose application of crystalloid triamcinolone showed significantly reduced impedances in the first fitting measurements compared to the control group. This effect was no longer detectable in patients of the low-dose group at that time. Looking at the different regions of the electrode, the impedance values were lowered significantly only at the basal and medial contacts. At later time points, there were no significant differences between any of the groups. This is the first study to demonstrate a dose-dependent reduction of impedances by deep intra-cochlear injection of triamcinolone in cochlear implant patients. With a high-dose, single application of triamcinolone using a cochlear catheter prior to insertion of a Flex28 electrode, the impedances can be significantly reduced up to and including the first fitting. Although the effect was longer lasting than when compared to low-dose triamcinolone, it was also not permanent.
A minimally-invasive surgical (MIS) approach to cochlear implantation, if safe, practical, simple in surgical handling, and also affordable has the potential to replace the conventional surgical approaches. Our MIS approach uses patient-specific drilling templates (positioning jigs). While the most popular MIS approaches use robots, the robotic aspect is literally put aside, because our high-precision parallel kinematics is only used to individualize a positioning jig. This jig can then be mounted onto a bone-anchored mini-stereotactic frame at the patient's skull and used to create a drill-hole through the temporal bone to the patient's cochlea. We present the first clinical experience where we use sham drill bits of different diameters instead of drilling into the bone in order to demonstrate the feasibility and accuracy.
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.
Background: After two decades from its introduction in the lateral skull base paraganglioma surgery, the indications and results of preoperative internal carotid artery stenting should be critically assessed. Materials and Methods: Monocentric retrospective study on 26 patients affected by head and neck paragangliomas (19 tympanojugular paragangliomas, 4 carotid body paragangliomas, 3 vagal paragangliomas) preoperatively treated with internal carotid artery stents between 2008 and 2023. The preoperative findings, the intraoperative complications and the final surgical results were analyzed. Results: The stent complication rate was less than 3.1%. Self-expanding highly flexible intracranial nitinol stents were applied. In all cases, it was possible to completely mobilize the internal carotid artery and perform a vascular dissection of the tumor. Gross total tumor resection was possible in 85% of cases. The median follow up was 7.83 y (SD +/− 3.93 y). No local recurrence was observed. Conclusions: The preoperative vascular stent facilitates tumor dissection from the internal carotid artery without risk of vascular damage, helping the surgeon to achieve surgical radicality. The vascular stent is indicated in the case of revision surgeries, circumferential involvement of the vessel and in cases with non-insufficient intracerebral crossflow. Procedural complications, temporary antiplatelet therapy and delay of surgery are the limitations of the procedure.
Zusammenfassung: Hintergrund: Aufgrund der großen anatomischen Vielfalt der menschlichen Cochleae existiert keine One-Size-Fits-All-Lösung für die Auswahl des optimalen Elektrodenträgers. Es muss individuell je nach Größe der Cochlea und anderen Faktoren wie dem präoperativ vorhandenen Restgehör entschieden werden. Ziele der Arbeit: Akzeptanz für Präzisionschirurgie zu schaffen und Grundlagen zu erläutern. Material und Methoden: Faktoren der Individualisierung werden erläutert und zukünftige Entwicklungen dargestellt. Ergebnisse: Wenn möglich, stellt die elektroakustische Stimulation die beste Versorgung dar. Bei alleiniger elektrischer Stimulation ist eine Abdeckung der Cochlea von etwa 80 % anzustreben. Schlussfolgerungen: Die jüngsten Fortschritte in der Cochleaimplantation markieren einen Paradigmenwechsel von standardisierten Lösungen hin zu einer personalisierten Herangehensweise, um somit die Rehabilitationsergebnisse zu optimieren.