Harmonic distortion in power networks has greatly reduced power quality and this affects system stability. In order to mitigate this power quality issue, the shunt active power filter (SAPF) has been widely applied and it is proven to be the best solution to current harmonics. This paper evaluates the performance of the modified synchronous reference frame extraction (MSRF) algorithm with fuzzy logic controller (FLC) based current control pulse width modulation (PWM) inverter of three-phase three-wire SAPF to mitigate current harmonics. The proposed FLC is designed with a reduced amount of membership functions (MFs) and rules, and thus significantly reduces the computational time and memory size. Modeling and simulations of SAPF are carried out using MATLAB/Simulink R2012a with the power system toolbox under steady-state condition, and this is followed with hardware implementation using a TMS320F28335 digital signal processor (DSP), Specrum Digital Inc., Stafford, TX, USA. The results obtained demonstrate a good and satisfactory response to mitigate the harmonics in the system. The total harmonic distortion (THD) for the system has been reduced from 25.60% to 0.92% and 1.41% in the simulation study with and without FLC, respectively. Similarly for the experimental study, the SAPF can compensate for the three-phase load current by reducing THD to 5.07% and 7.4% with and without FLC, respectively.
High-efficiency motors are being gradually introduced in many industrial applications because of their positive impacts on the environment by reducing energy consumption and CO2 emission. In this respect, line start permanent magnet synchronous motors (LS-PMSMs) have been introduced recently. Due to their unique configuration, LS-PMSMs allow the obtaining of super premium efficiency levels, accompanied with a high torque and power factor. However, since the use of LS-PMSMs in the industry is in its infancy, no efficient scheme has yet been reported for broken rotor bar (BRB) fault detection in this type of motor. Accordingly, the main aim of this research is to investigate the fault-related feature for BRB faults on LS-PMSMs. In this regard, a simulation model and experimental setup for the investigation of BRB in LS-PMSM are implemented. The detection strategy for BRB in LS-PMSM proposed here is based on the monitoring of the start-up current signal and discrete wavelet transform. The entropy features are used as fault-related features for BRB faults. Finally, the ability of these features is validated for the detection of BRB in LS-PMSM through statistical analysis. In this research, the importance of the starting load is also considered for BRB detection in LS-PMSMs.