Luis Adan Flores

Dr. Luis Adan Flores

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in Viruses
Verified
Journal Article
Open access
PDF file
FBFlavia Fonseca Bagno
Flavia Fonseca Bagno
LFLuis Adan Flores
Luis Adan Flores
SSSarah Aparecida Rodrigues Sérgio
Sarah Aparecida Rodrigues Sérgio
PPPierina Lorencini Parise
Pierina Lorencini Parise
DTDaniel A. Toledo-Teixeira
Daniel A. Toledo-Teixeira
Flavio FonsecaFlavio Fonseca
Flavio Fonseca
Previous studies have indicated that antibody responses can be robustly induced after the vaccination in individuals previously infected by SARS-CoV-2. To evaluate anti-SARS-CoV-2 humoral responses in vaccinated individuals with or without a previous history of COVID-19, we compared levels of anti-SARS-CoV-2 antibodies in the sera from 21 vaccinees, including COVID-19-recovered or -naïve individuals in different times, before and after immunization with an inactivated COVID-19 vaccine. Anti-SARS-CoV-2-specific antibodies elicited after COVID-19 and/or immunization with an inactivated vaccine were measured by ELISA and Plaque Reduction Neutralizing assays. Antibody kinetics were consistently different between the two vaccine doses for naïve individuals, contrasting with the SARS-CoV-2-recovered subjects in which we observed no additional increase in antibody levels following the second dose. Sera from SARS-CoV2-naïve individuals had no detectable neutralizing activity against lineage B.1 SARS-CoV-2 or Gamma variant five months after the second vaccine dose. Contrarily, SARS-CoV-2-recovered subjects retained considerable neutralizing activity against both viruses. We conclude that a single inactivated SARS-CoV-2 vaccine dose may be sufficient to induce protective antibody responses in individuals with previous history of SARS-CoV-2 infection.

14 October 2022 in Vaccines
Verified
Journal Article
Open access
PDF file
LFLuis Adan Flores
Luis Adan Flores
AVAlice Versiani
Alice Versiani
EBEdel F. Barbosa-Stancioli
Edel F. Barbosa-Stancioli
JRJenner Reis
Jenner Reis
JCJordana Grazziela Alves Coelho-dos-Reis
Jordana Grazziela Alves Coelho-dos-Reis
Flavio FonsecaFlavio Fonseca
Flavio Fonseca
The feline immunodeficiency virus (FIV) is a retrovirus with global impact and distribution, affecting both domestic and wild cats. This virus can cause severe and progressive immunosuppression culminating in the death of felids. Since the discovery of FIV, only one vaccine has been commercially available. This vaccine has proven efficiency against FIV subtypes A and D, whereas subtype B (FIV-B), found in multiple continents, is not currently preventable by vaccination. We, therefore, developed and evaluated a vaccine prototype against FIV-B using the recombinant viral vector modified vaccinia virus Ankara (MVA) expressing the variable region V1–V3 of the FIV-B envelope protein. We conducted preclinical tests in immunized mice (C57BL/6) using a prime-boost protocol with a 21 day interval and evaluated cellular and humoral responses as well the vaccine viability after lyophilization and storage. The animals immunized with the recombinant MVA/FIV virus developed specific splenocyte proliferation when stimulated with designed peptides. We also detected cellular and humoral immunity activation with IFN-y and antibody production. The data obtained in this study support further development of this immunogen and testing in cats.

29 June 2021 in medRxiv
Verified
Preprint
Open access
PDF file
FBFlavia Fonseca Bagno
Flavia Fonseca Bagno
SSSarah A. R. Sérgio
Sarah A. R. Sérgio
MFMaria Marta Figueiredo
Maria Marta Figueiredo
LGLara Godoi
Lara Godoi
LFLuis Adan Flores
Luis Adan Flores
Flavio FonsecaFlavio Fonseca
Flavio Fonseca
There is a massive demand to identify alternative methods to detect new cases of COVID-19 as well as to investigate the epidemiology of the disease. In many countries, importation of commercial kits poses a significant impact on their testing capacity and increases the costs for the public health system. We have developed an ELISA to detect IgG antibodies against SARS-CoV-2 using a recombinant viral nucleocapsid (rN) protein expressed in E. coli . Using a total of 894 clinical samples we showed that the rN-ELISA was able to detect IgG antibodies against SARS-CoV-2 with high sensitivity (97.5%) and specificity (96.3%) when compared to a commercial antibody test. After three external validation studies, we showed that the test accuracy was higher than 90%. The rN-ELISA IgG kit constitutes a convenient and specific method for the large-scale determination of SARS-Cov-2 antibodies in human sera with high reliability.

28 September 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
FCFabiana Fioravante Coelho
Fabiana Fioravante Coelho
MSMíriam Aparecida da SILVA
Míriam Aparecida da SILVA
TLThiciany Blener Lopes
Thiciany Blener Lopes
JPJuliana POLATTO
Juliana POLATTO
NCNatalia Salazar Castro
Natalia Salazar Castro
AFAna Paula Fernandes
Ana Paula Fernandes
SARS-CoV-2 diagnostic tests have become an important tool for pandemic control. Among the alternatives for COVID-19 diagnosis, antigen rapid diagnostic tests (Ag-RDT) are very convenient and widely used. However, as SARS-CoV-2 variants may continuously emerge, the replacement of tests and reagents may be required to maintain the sensitivity of Ag-RDTs. Here, we describe the development and validation of an Ag-RDT during an outbreak of the Omicron variant, including the characterization of a new monoclonal antibody (anti-DTC-N 1B3 mAb) that recognizes the Nucleocapsid protein (N). The anti-DTC-N 1B3 mAb recognized the sequence TFPPTEPKKDKKK located at the C-terminus of the N protein of main SARS-CoV-2 variants of concern. Accordingly, the Ag-RDT prototypes using the anti-DTC-N 1B3 mAB detected all the SARS-CoV-2 variants—Wuhan, Alpha, Gamma, Delta, P2 and Omicron. The performance of the best prototype (sensitivity of 95.2% for samples with Ct ≤ 25; specificity of 98.3% and overall accuracy of 85.0%) met the WHO recommendations. Moreover, results from a patients’ follow-up study indicated that, if performed within the first three days after onset of symptoms, the Ag-RDT displayed 100% sensitivity. Thus, the new mAb and the Ag-RDT developed herein may constitute alternative tools for COVID-19 point-of-care diagnosis and epidemiological surveillance.