In this study, aramid fiber (Kevlar® 29 fiber) and carbon fiber were added into concrete in a hybrid manner to enhance the static and impact mechanical properties. The coupling agent presence on the surface of carbon fibers was spotted in Scanning Electron Microscope (SEM) and energy-dispersive X-ray spectroscopy (EDS) graphs. The carbon fiber with a coupling agent affected the mechanical strength of the reinforced concrete. At 1% fiber/cement weight percentage, the hybrid fiber-reinforced concrete (HFRC) prepared using Kevlar fiber and carbon fiber of 12 and 24 mm in length under different mix proportions was investigated to determine the maximum mechanical strengths. From the test results, the mechanical strength of the HFRC attained better performance than that of the concrete with only Kevlar or carbon fibers. Foremost, the mix proportion of Kevlar/carbon fiber (50–50%) significantly improved the compressive, flexural, and splitting tensile strengths. Under different impact energies, the impact resistance of the HFRC specimen was much higher than that of the benchmark specimen, and the damage of the HFRC specimens was examined with an optical microscope to identify slippage or rupture failure of the fiber in concrete.
The 3D printing process is different from traditional construction methods of formwork casting due to the use of additive manufacturing. This study develops a suitable 3D-printed carbon fiber-reinforced cement mortar (CFRCM) considering the extrudability, fluidity, setting time, and buildability of the CFRCM. The difference in compressive strength and flexural strength between 3D-printed specimens and conventional cast specimens was investigated by varying the amount of carbon fiber added (carbon fiber to cement ratio, 2.5 vol.‰, 5 vol.‰, 7.5 vol.‰, and 10 vol.‰) and the curing times (7th day and 28th day). The results of the experiments indicate that the addition of 6 wt.% cement accelerators to the cementitious mortar allows for a controlled initial setting time of approximately half an hour. The fluidity of the CFRCM was controlled by adjusting the dosage of the superplasticizer. When the slump was in the range of 150 mm to 190 mm, the carbon fiber to cement ratio 2.5 vol.‰ could be incorporated into the cementitious mortar, enabling the printing of hollow cylinders with a height of up to 750 mm. Comparing the 3D-printed specimens with the traditionally cast specimens, it was found that the addition of a carbon fiber to cement ratio of 7.5 vol.‰, and 10 vol.‰ resulted in the optimal compressive strength and flexural strength, respectively.
Fiber-reinforced polymer (FRP) has been used for seismic retrofitting and structural reinforcement over recent decades. Numerous researchers have created stress–strain models based on experimental data to predict the mechanical properties of FRP-confined concrete. In this study, circular and square cross-section specimens with different design concrete strength were prepared, and the compressive strength of the specimens confined with different layers of aramid FRP (AFRP) were measured in compressive tests. A constitutive model was proposed to simulate the uniaxial compressive stress–strain relationship of the AFRP-confined concrete, which was derived from the Mohr–Coulomb failure envelope theory, and the corresponding axial strain was determined from the regression analysis. The internal friction angle of the proposed constitutive model was determined for the cylindrical concrete specimens confined with one and two layers of AFRP. The compressive strength of one and two layers of AFRP-confined concrete specimens were used to obtain the parameters of the constitutive model; the absolute average error between experimental and predicted compressive strength was 7.01%. Then, the constitutive model was used to predict the strength of a three-layer AFRP-confined concrete specimen, and the absolute average error was 4.95%. The cross-sectional shape coefficient of the square concrete specimen was obtained analytically. Substituting the cross-sectional shape coefficient into the proposed constitutive model, the average absolute error of the square cross-section concrete specimen was about 3.84%. The results indicated that the proposed constitutive model can predict the compressive strength of circular and square cross-section concrete specimens confined with AFRP.
Columnar inclusion is a versatile and cost-effective technique for improving weak soils. Currently, most approaches are based on the “equal strain” assumption to calculate the deformation of soft ground reinforced by columnar inclusions. In this study, a new model to simulate the behavior of column-reinforced soft soil under equal stress conditions based on the variational principles is proposed. The proposed model satisfies the force equilibrium and deformation compatibility simultaneously, which is seldom fulfilled in traditional empirical methods or other analytical models. The corresponding analytical solution is obtained and its accuracy is verified by comparing it with the numerical solutions using finite element analysis. The comparisons of the proposed solution with an existing solution show that the proposed solution can provide very close agreement over a wide range of parameters while the existing solution is only able to provide a reasonable agreement for a certain range of stiffness ratio of the column and soft ground. In addition, a parametric study is made to illustrate the influence of various parameters on ground settlement predictions. The parametric study indicated that, by increasing the ratio of elastic modulus between the stone column and surrounding soils and the ratio between the radius of the stone column and the space of the stone column, the load transfer effect has been significantly improved, and the ground settlement becomes smaller. Furthermore, the Poisson’s ratio of the surrounding soil also has a very significant effect on ground settlement, while the effect of the Poisson’s ratio of the stone column on ground settlement is less significant compared with that of the surrounding soil.
This study developed 3D-printable cement mortar (3DPCM) incorporating modified basic oxygen furnace slag (MBOFS) sand and waste printed circuit board powder (WPCBP). Five WPCBP-to-cement ratios, namely 0, 10, 20, 30, and 40 wt.%, were adopted, and the printability of each mixture was first evaluated. Subsequently, the compressive, flexural, and splitting tensile behaviors of mold-cast and 3D-printed specimens were compared, and the structural response of 3D-printed truss members was assessed through four-point bending tests and finite element analysis. The results showed that all mixtures could be printed stably. For the standard 3D-printed specimens, WPCBP/C = 20 wt.% provided the highest quasi-static mechanical performance, and the mechanical response exhibited clear anisotropic behavior. In contrast, the mechanical performance of the mold-cast specimens decreased with increasing WPCBP content. In the 3D-printed truss members, the average peak load increased from 8.041 to 20.710 kN, the displacement corresponding to the peak load increased from 0.201 to 0.683 mm, and the finite element analysis reasonably captured the overall load–displacement response. Overall, MBOFS sand and WPCBP can be effectively incorporated into 3DPCM and show potential for sustainable structural material applications.