Extended reality (XR), which encompasses virtual, augmented and mixed reality, is an emerging medical imaging display platform which enables intuitive and immersive interaction in a three-dimensional space. This technology holds the potential to enhance understanding of complex spatial relationships when planning and guiding cardiac procedures in congenital and structural heart disease moving beyond conventional 2D and 3D image displays. A systematic review of the literature demonstrates a rapid increase in publications describing adoption of this technology. At least 33 XR systems have been described, with many demonstrating proof of concept, but with no specific mention of regulatory approval including some prospective studies. Validation remains limited, and true clinical benefit difficult to measure. This review describes and critically appraises the range of XR technologies and its applications for procedural planning and guidance in structural heart disease while discussing the challenges that need to be overcome in future studies to achieve safe and effective clinical adoption.

1 December 2024 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
NSNatasha Stephenson
Natasha Stephenson
EREric Rosenthal
Eric Rosenthal
MJMatthew Jones
Matthew Jones
SDShujie Deng
Shujie Deng
GWGavin Wheeler
Gavin Wheeler
JSJohn Simpson
John Simpson
BACKGROUND: Covered stent correction (CSC) of a superior sinus venosus atrial septal defect is an alternative to surgery in selected patients, but anatomic variation means that assessment for CSC requires a 3-dimensional anatomic understanding. Heart VR is a virtual reality (VR) system that rapidly displays and renders multimodality imaging without prior image segmentation. The aim of this study was to evaluate the performance of the Heart VR system to assess patient suitability for CSC. METHODS: In a blinded fashion, 2 interventionalists reviewed preprocedural computed tomography scans using Heart VR to assess the feasibility of CSC, including the potential need for pulmonary vein protection. The total review time using VR was recorded. RESULTS: Using conventional imaging, 15 patients were deemed suitable for CSC, but at catheterization, 3 cases were unsuitable. Using VR, when both interventionalists agreed that a case was suitable for CSC (n=12), all proved technically feasible. In the 3 cases that were unsuitable for CSC, the interventionalists using VR were either uncertain (n=1) or did not agree on suitability (n=2). The strategy for pulmonary vein protection was correctly identified by interventionalist 1 and 2 in 9/12 and 8/12 cases, respectively. In cases where pulmonary vein protection was required intraprocedurally (n=5), this was correctly identified using Heart VR. Using VR, in 3 cases it was determined that pulmonary vein protection would be required, but this was not the case on balloon interrogation. VR data loading and review times were 82 seconds and 7 minutes, respectively. Verbal feedback indicated that Heart VR assisted in the assessment of case suitability. CONCLUSIONS: Heart VR is a rapid and effective tool for predicting suitability for CSC in patients with a superior sinus venosus atrial septal defect and could be a feasible alternative to segmented virtual or physical 3-dimensional models.

8 November 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
NSNatasha Stephenson
Natasha Stephenson
KPKuberan Pushparajah
Kuberan Pushparajah
GWGavin Wheeler
Gavin Wheeler
SDShujie Deng
Shujie Deng
JSJulia A. Schnabel
Julia A. Schnabel
JSJohn Simpson
John Simpson
This study aimed to evaluate the accuracy and reliability of a virtual reality (VR) system line measurement tool using phantom data across three cardiac imaging modalities: three-dimensional echocardiography (3DE), computed tomography (CT) and magnetic resonance imaging (MRI). The same phantoms were also measured using industry-standard image visualisation software packages. Two participants performed blinded measurements on volume-rendered images of standard phantoms both in VR and on an industry-standard image visualisation platform. The intra- and interrater reliability of the VR measurement method was evaluated by intraclass correlation coefficient (ICC) and coefficient of variance (CV). Measurement accuracy was analysed using Bland–Altman and mean absolute percentage error (MAPE). VR measurements showed good intra- and interobserver reliability (ICC ≥ 0.99, p < 0.05; CV < 10%) across all imaging modalities. MAPE for VR measurements compared to ground truth were 1.6%, 1.6% and 7.7% in MRI, CT and 3DE datasets, respectively. Bland–Altman analysis demonstrated no systematic measurement bias in CT or MRI data in VR compared to ground truth. A small bias toward smaller measurements in 3DE data was seen in both VR (mean −0.52 mm [−0.16 to −0.88]) and the standard platform (mean −0.22 mm [−0.03 to −0.40]) when compared to ground truth. Limits of agreement for measurements across all modalities were similar in VR and standard software. This study has shown good measurement accuracy and reliability of VR in CT and MRI data with a higher MAPE for 3DE data. This may relate to the overall smaller measurement dimensions within the 3DE phantom. Further evaluation is required of all modalities for assessment of measurements <10 mm.