Matthew Jones

Dr. Matthew Jones

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2024 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
Gianfranco ButeraGianfranco Butera
Gianfranco Butera
EPEnrico Piccinelli
Enrico Piccinelli
AKAdam Kolesnik
Adam Kolesnik
KAKonstantin Averin
Konstantin Averin
CSCameron Seaman
Cameron Seaman
GRGrazyna Brzezinska Rajszys
Grazyna Brzezinska Rajszys
Background: The Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD).Objectives: The authors sought to investigate the feasibility, safety, and short-term follow-up of AFR implantation in patients with CHD or children with PH or cardiomyopathy.Methods: This is a multicenter retrospective study involving 10 centers worldwide. Patients of any age with CHD or patients aged < 18 years with PH or cardiomyopathy needing AFR implantation were included.Results: A total of 40 patients underwent AFR implantation. The median age of the population at the time of the procedure was 58.5 months (IQR: 31.5–142.5) and the median weight was 17 kg (IQR: 10–46). A total of 26 (65.0%) patients had CHD, nine (22.5%) children, a cardiomyopathy, and five (12.5%), a structurally normal heart. The implantation success rate was 100%. There were two early and one late device thrombosis. Two patients (5.0%) with dilated cardiomyopathy on extracorporeal membrane oxygenator (ECMO) died during the hospital stay. At a median follow-up of 330 days (IQR: 125–593), 37 (92.5%) patients were alive. At follow-up, 20 patients improved their New York Heart Association (NYHA) class, 12 patients did not change their NYHA class, and one patient with idiopathic PH worsened.Conclusions: AFR implantation in patients with CHD and children with severe PH or cardiomyopathy is promising and seems to have beneficial effects at short-term follow-up.

18 March 2025 in Circulation
Verified
Journal Article
Open access
EREric Rosenthal
Eric Rosenthal
SQShakeel A. Qureshi
Shakeel A. Qureshi
KSKothandam Sivakumar
Kothandam Sivakumar
MJMatthew Jones
Matthew Jones
SYSan-Fui Yong
San-Fui Yong
EZEvan M. Zahn
Evan M. Zahn
BACKGROUND: Covered stent correction for a sinus venosus atrial septal defect (SVASD) was first performed in 2009. This innovative approach was initially viewed as experimental and was reserved for highly selected patients with unusual anatomic variants. In 2016, increasing numbers of procedures began to be performed, and in several centers, it is now offered as a standard of care option alongside surgical repair. However, covered stent correction for SVASD is not recognized by regulatory authorities, and in the minds of many pediatric and adult congenital cardiologists and surgeons, the condition is viewed as treatable only by cardiac surgery with cardiopulmonary bypass. METHODS: In April 2023, all centers identified from international conferences, publications, and colleague networks to be undertaking covered stent correction for SVASD were invited to participate in a retrospective audit of their procedures. RESULTS: Data were received on 381 patients from 54 units over a 12-year period with 90% of procedures being performed over the past 5 years. Balloon-expandable stents (8 types) were used in the majority; self-expanding stents (4 types) were used in 4.5%. The commonest stent was the 10-zig covered Cheatham Platinum stent in 62% of cases. In 10 procedures, the stent embolized requiring surgical retrieval and repair of the defect, resulting in technically successful implantation in 371 of 381 (97.4%). Major complications (surgical drainage of tamponade, pacemaker implantation, surgery for pulmonary vein occlusion, and late stent removal) occurred in 5 patients (1.3%). Repeat catheterization to correct residual leaks was required in 7 patients (1.8%). Thus, 359 of 381 patients (94.2%) had successful correction without major complications or additional catheter interventions. CONCLUSIONS: This article details the exponential uptake of covered stent correction for SVASD during the past 5 years. Cardiopulmonary bypass was avoided in the majority of patients, and major complications were infrequent. Prospective registries with standardized definitions, inclusion criteria, and follow-up and comparative studies with surgery are now required to help support the extension of covered stent correction as an alternative standard-of-care option for patients with an SVASD.

30 May 2018 in F1000Research
Verified
Journal Article
Open access
PDF file
MJMatthew Jones
Matthew Jones
Shakeel QureshiShakeel Qureshi
Shakeel Qureshi
Surgical repair of tetralogy of Fallot (ToF) in childhood is associated with generally good outcomes, and almost all children can be expected to survive until adulthood. However, significant pulmonary regurgitation leading to progressive right ventricular dilatation is common in teenagers or young adults because of the nature of the surgical intervention. In patients whose repair included placement of a right ventricle to pulmonary artery conduit, it has been possible to place a stented valve within the conduit to treat this. Pulmonary regurgitation after repair of ToF via a transannular patch technique has historically involved repeat surgery as the dimensions of the right ventricular outflow tract have been too large for commercially available valves. This review summarises the novel transcatheter valves available for management of pulmonary regurgitation after surgical repair of ToF in patients in whom the dimensions of the right ventricular outflow tract have previously been considered too large for transcatheter valve implantation.

1 December 2024 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
NSNatasha Stephenson
Natasha Stephenson
EREric Rosenthal
Eric Rosenthal
MJMatthew Jones
Matthew Jones
SDShujie Deng
Shujie Deng
GWGavin Wheeler
Gavin Wheeler
JSJohn Simpson
John Simpson
BACKGROUND: Covered stent correction (CSC) of a superior sinus venosus atrial septal defect is an alternative to surgery in selected patients, but anatomic variation means that assessment for CSC requires a 3-dimensional anatomic understanding. Heart VR is a virtual reality (VR) system that rapidly displays and renders multimodality imaging without prior image segmentation. The aim of this study was to evaluate the performance of the Heart VR system to assess patient suitability for CSC. METHODS: In a blinded fashion, 2 interventionalists reviewed preprocedural computed tomography scans using Heart VR to assess the feasibility of CSC, including the potential need for pulmonary vein protection. The total review time using VR was recorded. RESULTS: Using conventional imaging, 15 patients were deemed suitable for CSC, but at catheterization, 3 cases were unsuitable. Using VR, when both interventionalists agreed that a case was suitable for CSC (n=12), all proved technically feasible. In the 3 cases that were unsuitable for CSC, the interventionalists using VR were either uncertain (n=1) or did not agree on suitability (n=2). The strategy for pulmonary vein protection was correctly identified by interventionalist 1 and 2 in 9/12 and 8/12 cases, respectively. In cases where pulmonary vein protection was required intraprocedurally (n=5), this was correctly identified using Heart VR. Using VR, in 3 cases it was determined that pulmonary vein protection would be required, but this was not the case on balloon interrogation. VR data loading and review times were 82 seconds and 7 minutes, respectively. Verbal feedback indicated that Heart VR assisted in the assessment of case suitability. CONCLUSIONS: Heart VR is a rapid and effective tool for predicting suitability for CSC in patients with a superior sinus venosus atrial septal defect and could be a feasible alternative to segmented virtual or physical 3-dimensional models.

Verified
Journal Article
Open access
PDF file
MRMicol Rebonato
Micol Rebonato
MPMara Pilati
Mara Pilati
MSMalekzadeh-Milani Sophie
Malekzadeh-Milani Sophie
Damien BonnetDamien Bonnet
Damien Bonnet
EPEmma Pascall
Emma Pascall
Gianfranco ButeraGianfranco Butera
Gianfranco Butera
Background: Stent implantation has become the preferred method of treatment for treating vessel stenosis in congenital heart diseases. The availability of covered stents may decrease complications and have an important role in the management of patients with complex anatomy. Aim: This study aims to evaluate the feasibility and safety of the pre-mounted cobalt–chromium stent-graft-covered ePTFE Aortic BeGraft in a broad spectrum of vascular lesions. Methods: This is a multicenter retrospective results analysis of 107 implanted BeGraft stents between 2016 and 2022 in six different European centers. Results: One hundred and four patients with a mean age of thirteen years (range 1–70 years) and with the body weight of 56.5 kg (range 11–115 kg) underwent the BeGraft stent implantation. Stents were implanted in the following conditions: aortic coarctation (74 patients), RVOT dysfunction (12 patients), Fontan circulation (7 patients), and miscellaneous (11 subjects with complex CHD). All the stents were implanted successfully. The median stent diameter was 16 mm (range 7–24 mm), and the median length was 39 mm (range 19–49 mm). Major complications occurred in five subjects (4.7%). During a median follow-up of fourteen (1–70) months, stents’ re-dilatation was performed in five patients. Conclusions: The BeGraft stent can be used safely and effectively in a wide spectrum of congenital heart diseases. Whether these good results will be stable in the longer term still needs to be investigated in a follow-up given its recent introduction into clinical practice, in particular regarding stent fracture or neointimal proliferation.

19 February 2025 in Current Cardiology Reports
Verified
Journal Article
Open access
PDF file
NLNaychi Lwin
Naychi Lwin
PSPiia Suursalmi
Piia Suursalmi
SYSophia Yong
Sophia Yong
SKSaleha Kabir
Saleha Kabir
MJMatthew Jones
Matthew Jones
EREric Rosenthal
Eric Rosenthal
Purpose of Review: To provide an overview of fluoroscopy-free transcatheter atrial septal defect (ASD) closure and introduce a simplified approach that avoids pulmonary vein instrumentation. Recent Findings: Since the first reported fluoroscopy-free ASD closure 24 years ago, only a few small series have described this technique. We present a simplified and less cumbersome approach to encourage wider adoption of the fluoroscopy-free method to suitable ASD anatomy. Results: Fluoroscopy free ASD closure was performed in 9 patients using the conventional technique (Group 1) and 23 patients using our simplified approach of direct placement of the device into the defect (Group 2). Median age and weight were 28 years, 53 kg in Group 1 (range: 5–52 years, 22–88 kg) and 36 years, 66 kg in Group 2 (range: 4–76 years, 16–115 kg). Devices were successfully implanted in all patients, with a median device size of 21 mm (Group 1: 9–36 mm, Group 2: 10–33 mm). Procedural time was 47 min for Group 1 and 35 min for Group 2 ( p = 0.09). Length of hospital stay was similar in both groups. There were no acute or long-term complications and no need for reintervention. Summary: Transcatheter ASD closure without the use of fluoroscopy using the simplified approach is safe and effective, offers a shorter procedure duration and minimises instrumentation within the left atrium and pulmonary veins. Patient selection is key and with greater experience, this procedure may be applicable to a wider selection of ASD anatomy.