Stefan Fiedler

Dr. Stefan Fiedler

Instrumentation, European Molecular Biology Laboratory, Hamburg, Germany
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
TBThomas Breslin
Thomas Breslin
JPJason Paino
Jason Paino
MWMarie Wegner
Marie Wegner
EEElette Engels
Elette Engels
SFStefan Fiedler
Stefan Fiedler
ESElisabeth Schültke
Elisabeth Schültke
The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

4 February 2015 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
CBClement Blanchet
Clement Blanchet
CHChristoph Hermes
Christoph Hermes
DSDmitri I. Svergun
Dmitri I. Svergun
SFStefan Fiedler
Stefan Fiedler
A small active in-vacuum beamstop has been developed to monitor the flux of intense third-generation synchrotron X-ray beams protecting the downstream detector from the direct beam. Standard active beamstops, where a built-in diode directly absorbs the beam, have limitations in size and lifetime. In the present design, a silicon PIN diode detects the photons back-scattered from a cavity in the beamstop. This approach drastically reduces the radiation dose on the diode and thus increases its lifetime. The beamstop with a diameter of 2 mm has been fabricated to meet the requirements for the P12 bioSAXS beamline of EMBL Hamburg at PETRA III (DESY). The beamstop is in regular user operation at the beamline and displays a good response over the range of energies tested (6–20 keV). Further miniaturization of the diode is easily possible as its size is not limited by the PIN diode used.

Verified
Journal Article
Open access
PDF file
MAMunir A. Al-Zeer
Munir A. Al-Zeer
FPFranziska Prehn
Franziska Prehn
SFStefan Fiedler
Stefan Fiedler
ULUlrich Lienert
Ulrich Lienert
MKMichael Krisch
Michael Krisch
ESElisabeth Schültke
Elisabeth Schültke
Radiotherapy is an important component in the treatment of lung cancer, one of the most common cancers worldwide, frequently resulting in death within only a few years of diagnosis. In order to evaluate new therapeutic approaches and compare their efficiency with regard to tumour control at a pre-clinical stage, it is important to develop standardized samples which can serve as inter-institutional outcome controls, independent of differences in local technical parameters or specific techniques. Recent developments in 3D bioprinting techniques could provide a sophisticated solution to this challenge. We have conducted a pilot project to evaluate the suitability of standardized samples generated from 3D printed human lung cancer cells in radiotherapy studies. The samples were irradiated at high dose rates using both broad beam and microbeam techniques. We found the 3D printed constructs to be sufficiently mechanically stable for use in microbeam studies with peak doses up to 400 Gy to test for cytotoxicity, DNA damage, and cancer cell death in vitro. The results of this study show how 3D structures generated from human lung cancer cells in an additive printing process can be used to study the effects of radiotherapy in a standardized manner.

20 October 2022 in Cancers
Verified
Journal Article
Open access
PDF file
ESElisabeth Schültke
Elisabeth Schültke
SFStefan Fiedler
Stefan Fiedler
CMCatharina Mewes
Catharina Mewes
EGElisabetta Gargioni
Elisabetta Gargioni
JKJohannes Klingenberg
Johannes Klingenberg
GHGuido Hildebrandt
Guido Hildebrandt
High dose rate radiotherapies such as FLASH and microbeam radiotherapy (MRT) both have developed to the stage of first veterinary studies within the last decade. With the development of a new research tool for high dose rate radiotherapy at the end station P61A of the synchrotron beamline P61 on the DESY campus in Hamburg, we increased the research capacity in this field to speed up the translation of the radiotherapy techniques which are still experimental, from bench to bedside. At P61, dose rates of several hundred Gy/s can be delivered. Compared to dedicated biomedical beamlines, the beam width available for MRT experiments is a very restrictive factor. We developed two model systems specifically to suit these specific technical parameters and tested them in a first set of experiments.

15 February 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ESElisabeth Schültke
Elisabeth Schültke
SFStefan Fiedler
Stefan Fiedler
RMRalf Hendrik Menk
Ralf Hendrik Menk
FJFelix Jaekel
Felix Jaekel
DDDiego Dreossi
Diego Dreossi
FAFulvia Arfelli
Fulvia Arfelli
It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm. Murine melanoma cell cultures were irradiated with a target dose of approximately 65 Gy at a mean photon energy of ∼30 keV with a dose rate of 70 Gy s−1 and a peak-to-valley dose of ∼123. This work demonstrated a melanoma cell reduction of approximately 80% after MBI. It is suggested that, while a high energy is essential to achieve high dose rates in order to deposit high treatment doses in a short time in a deep-seated target, for in vitro studies and for the treatment of superficial tumours a spectrum in the lower energy range might be equally suitable or even advantageous.

18 May 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ESElisabeth Schültke
Elisabeth Schültke
MLMichael Lerch
Michael Lerch
TKTimo Kirschstein
Timo Kirschstein
FLFalko Lange
Falko Lange
KPKatrin Porath
Katrin Porath
GHGuido Hildebrandt
Guido Hildebrandt
Microbeam radiotherapy could help to cure malignant tumours which are currently still considered therapy-resistant. With an irradiation target in the thoracic cavity, the heart would be one of the most important organs at risk. To assess the acute adverse effects of microbeam irradiation in the heart, a powerful ex vivo tool was created by combining the Langendorff model of the isolated beating mammalian heart with X-Tream dosimetry. In a first pilot experiment conducted at the Biomedical and Imaging Beamline of the Australian Synchrotron, the system was tested at a microbeam peak dose approximately ten times higher than the anticipated future microbeam irradiation treatment doses. The entire heart was irradiated with a dose of 4000 Gy at a dose rate of >6000 Gy s−1, using an array of 50 µm-wide microbeams spaced at a centre-to-centre distance of 400 µm. Although temporary arrhythmias were seen, they reverted spontaneously to a stable rhythm and no cardiac arrest occurred. This amazing preservation of cardiac function is promising for future therapeutic approaches.