Muhammadu Masin Muhammadu

Dr. Muhammadu Masin Muhammadu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2024 in Journal of Advanced Research in Numerical Heat Transfer
Verified
Journal Article
Open access
PDF file
MAMuhammad Aidil Safwan Abdul Aziz
Muhammad Aidil Safwan Abdul Aziz
NDNofrizalidris Darlis
Nofrizalidris Darlis
IIIzuan Amin Ishak
Izuan Amin Ishak
NZNor Atiqah Zolpakar
Nor Atiqah Zolpakar
MAMohammad Arafat
Mohammad Arafat
MMMuhammadu Masin Muhammadu
Muhammadu Masin Muhammadu
The increasing miniaturization of technology has intensified thermal challenges, particularly concerning the cooling of small components like ICs and CPUs. Microchannel heat sinks offer a common solution, but optimizing their configurations remains a subject of interest. This study addresses multiple thermal enhancing factors that is position of the inlet and outlet and integrating pin-fin configurations. The objectives of the study are to improve the thermal uniformity of the heat sink and to analyse the thermal performance across the different geometry of pin-fin using Ansys. The thermal performance parameters focused on this study are the maximum temperature and pressure drop. The results gathered that hexagon shaped pin fin yield better thermal performance as compared to the other geometry as it shows the lowest maximum temperature, lowest thermal resistance and lowest pressure drop. This proves the significance of geometry selection for the pin fin as it affected the thermal performance of the microchannel heat sink with cross flow effects.

22 September 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
LALuqman Muhammed Audu
Luqman Muhammed Audu
NMNicholas Akhaze Musa
Nicholas Akhaze Musa
ANAbdulkarim Nasir
Abdulkarim Nasir
MMMuhammadu Masin Muhammadu
Muhammadu Masin Muhammadu
The paper presents a model to carry out a short-term flow data extension for a minimum of 30 years using the Gauss–Newton Empirical Regression Algorithm (GNRA) for the determination of the hydropower generation capacity of rivers in ungauged channels. An averaged 2 years of precipitation, observed experimental discharged data, and 30 years of historical and predictive precipitation data were used to generate a regression model equation after authentication analysis. A minimum, average, and maximum of 30 years of historical, and predictive discharge data and power characteristics of the river were generated. A discharge predictive accuracy of 96.71% and a Pearson Correlation Coefficient of 0.954 were established between the experimental and model results. The river has minimum, average, and peak power potentials of 5 MW, 10 MW, and 20 MW, respectively, and is capable of yielding power throughout the year.

7 April 2025 in Journal of Advances in Fluid, Heat, and Materials Engineering
Verified
Journal Article
Open access
PDF file
NINir. Izzati
Nir. Izzati
ITIshkrizat Taib
Ishkrizat Taib
LJLiew Chuan Yang Jackson
Liew Chuan Yang Jackson
TSTian Xyi See
Tian Xyi See
HCHao Wei Chai
Hao Wei Chai
AAAndril Arafat
Andril Arafat
Heat exchangers are crucial components for various industrial applications, including oil refining, chemical processing, and power generation. Despite extensive research on heat exchanger performance, the impact of tube geometry on heat transfer efficiency requires further investigation. This study aims to address this gap by comparing the thermal performances of circular and elliptical double-tube heat exchangers using computational fluid dynamics (CFD) analysis. Models of both geometries were created using ANSYS software, and simulations were conducted at varying mass flow rates (0.04 kg/s, 0.07 kg/s, and 0.55 kg/s) to evaluate the heat transfer and fluid flow characteristics. The study found that circular tubes consistently outperformed elliptical tubes in terms of the heat transfer efficiency across all tested flow rates. Specifically, the circular tubes exhibited higher temperature increases in cold water and greater temperature decreases in hot water, as visualised in the temperature contours.

25 April 2025 in Semarak Journal of Thermal Fluid Engineering
Verified
Journal Article
Open access
PDF file
MFMeng Kit Foong
Meng Kit Foong
ITIshkrizat Taib
Ishkrizat Taib
MIMohamad Hisyamuddin Ishak
Mohamad Hisyamuddin Ishak
MFMohamad Faris Fauzi
Mohamad Faris Fauzi
TMTengku Izzat Azraei Tengku Mohamad Muhibuddin
Tengku Izzat Azraei Tengku Mohamad Muhibuddin
MMMuhammadu Masin Muhammadu
Muhammadu Masin Muhammadu
Fire Water Sprinkler is one of reliable equipment to control fire in building. This equipment also known as a simple and cost-effective method to control fire growth in a building. The systems work by blowing the water droplet into the burning area. The objective of this project is to analyze the behaviour and distribution of discharged water from fire water sprinkler. The computer fluid dynamics (CFD) is used to study the dispersion of water into the room or case study area. However, due to limitation of study, this simulation only carried out by using a room and single fire water sprinkler. This also important factor as the validation of the model is based on previous study. In addition, the project also to determine the effect of different operating pressure on water discharged from fire sprinkler. The project started with the data finding. It was important to identify the reference data to ensure the generate result was reasonable. The input water inlet pressure is in the range of 10 to 15 bar. The geometry of room was set to 4.0 m x 3.0 m x 4.0 m. The fire was assumed to start at the rectangular table which is the dimension is 1.0 m x 1.0 m and 0.5 m above the floor in the middle room. For boundary condition, the inlet parameter is velocity and the input magnitude set at 44.7 m/s under 10 bars. 1000 number of iterations was set in this project. The results showed the model of 15 bar operating pressure was managed to dispense the water jet down to rectangular table. The 15-bar operating pressure of the model has greatest velocity discharged up to 12.896 m/s. As conclusion, the operating pressure was affected the discharged of the water velocity. The increase of the operating pressure was led to greater water velocity discharged.

25 April 2025 in Semarak Journal of Thermal Fluid Engineering
Verified
Journal Article
Open access
PDF file
SKSaddam Kamarudin
Saddam Kamarudin
ITIskhrizat Taib
Iskhrizat Taib
MSMuhammad Shaiful Izzat Shaharudin
Muhammad Shaiful Izzat Shaharudin
MNMuhammad Aiman Nasri
Muhammad Aiman Nasri
MMMuhammadu Masin Muhammadu
Muhammadu Masin Muhammadu
MRMuhammad Nur Aiman Rahmat
Muhammad Nur Aiman Rahmat
Shell and tube heat exchangers are among the most common equipment in industrial processes because of their heat exchange efficiency. However, designing these heat exchangers to enhance their performance can be cumbersome and time-consuming. This study focuses on evaluating the performance of shell and tube heat exchangers with different numbers of baffles placed inside the shell, and identifying the most suitable turbulence model. In this study, the flow characteristics inside the heat exchangers were modelled using three turbulence models: Spalart-Allmaras, k-ε standard, and k-ε realisable models. The simulations were performed with the number of baffles ranging from one to seven to understand their effect on heat transfer and pressure drop. When the number of baffles in the heat exchanger increases, the pressure drop across the heat exchanger also increases. Model D exhibited maximum pressure distribution, which occurred with 12 baffles. The velocity streamlines from the experiment showed that a higher number of baffles led to an increase in flow. This study also aimed to compare three turbulence models, and the results indicated that the k-ε realisable model performed the best of the three models. This study also highlights the importance of designing a shell and tube heat exchanger with an appropriate number of baffles. Although more baffling is advantageous for heat transfer, it also results in a higher pressure drop. In summary, as evidenced by the results presented in this paper, the baffle design is crucial for heat exchangers.