Yuchao Guo

Dr. Yuchao Guo

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2022 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
XLXianbao Liu
Xianbao Liu
JFJiaqi Fan
Jiaqi Fan
YGYuchao Guo
Yuchao Guo
HDHanyi Dai
Hanyi Dai
JXJianguo Xu
Jianguo Xu
JWJian’an Wang
Jian’an Wang
Background: In the recent decades, the development of novel digital health technologies enables doctors to monitor ECG and vital signs remotely. But the data on applying the noninvasive wearable smartwatch on patients with transcatheter aortic valve replacement (TAVR) are unknown. Methods and Results: We performed a prospective, observational cohort study to evaluate the feasibility of a novel, virtual, and remote health care strategy for patients with TAVR discharged to home with smart wearable devices. A total of 100 consecutive patients with severe aortic stenosis who underwent elective transfemoral TAVR were enrolled and received the Huawei smartwatch at least 1 day before TAVR. Vital signs, including heart rate, rhythm, oxygen saturation, and activity, were continuously recorded. Single‐lead ECG was recorded twice per day in the week following TAVR discharge and at least 2 days a week for the subsequent month after TAVR discharge. A designated heart team member provided remote health care with the data from the smartwatch when the patient had a need. Thirty‐eight cardiac events were reported in 34 patients after discharge, with most of the events (76.0%) detected and confirmed by the smartwatch. Six patients were advised and readmitted to the hospital for arrhythmia events detected by the smartwatch, of whom 4 patients received pacemaker implantation. The remaining 28 (82.4%) patients received telemedicine monitoring instead of face‐to‐face clinical visits, and 3 of them received new medication treatment under the online guidance of doctors. New‐onset left branch bundle block was found in 48 patients, with transient characteristics, and recovered spontaneously in 30 patients, and new‐onset atrial fibrillation was detected in 4 patients. There were no significant differences in the average weekly heart rates or the ratio of abnormal or low oxygen saturation when compared with the baseline. The average daily steps increased over time significantly (baseline, 870±1353 steps; first week, 1986±2406 steps; second week, 2707±2716 steps; third week, 3059±3036 steps; fourth week, 3678±3485 steps, P <0.001). Conclusions: Smartwatches can facilitate remote health care for patients discharged to home after undergoing TAVR and enable a novel remote follow‐up strategy. The majority of cardiac clinical events that occurred within 30‐day follow‐up were detected by the smartwatch, mainly because of the record of conduction abnormality. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04454177.

4 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YGYuchao Guo
Yuchao Guo
SXShaojun Xu
Shaojun Xu
HZHong Zhan
Hong Zhan
HCHan Chen
Han Chen
PHPo Hu
Po Hu
JWJian’an Wang
Jian’an Wang
Objective: Trimethylamine N-oxide (TMAO), a pathological microbial metabolite, is demonstrated to be related to cardiovascular diseases. This study was (1) to investigate the association between TMAO and aortic stenosis and (2) to determine the prognostic value of TMAO for predicting mortality after transcatheter aortic valve replacement (TAVR). Methods: 299 consecutive patients (77 (72–81) years, 58.2% male, Society of Thoracic Surgeons (STS) score 5.8 (4.9–9.3)) with severe aortic stenosis and 711 patients (59 (52–66) years, 51.9% male) without aortic stenosis were included in this retrospective study. A total of 126 pairs of patients were assembled by Propensity Score Matching. The primary outcome was all-cause mortality using survival analyses stratified by TMAO quartiles. Results: Patients with severe aortic stenosis had higher TMAO levels (3.18 (1.77–6.91) μmol/L vs. 1.78 (1.14–2.68) μmol/L, p < 0.001), and TMAO remained significantly higher after adjusting for baseline characteristics. Higher TMAO level was associated with higher 2-year all-cause mortality (19.2% vs. 9.5%, log-rank p = 0.028) and higher late cumulative mortality (34.2% vs. 19.1%, log-rank p = 0.004). In Cox regression multivariate analysis, higher TMAO level remained an independent predictor (hazard ratio 1.788; 95% CI 1.064–3.005, p = 0.028) of all-cause mortality after adjusting for STS score, N-terminal pro b-type natriuretic peptide, and maximum velocity. Conclusions: The TMAO level was higher in aortic stenosis patients. Elevated TMAO was associated with poor adverse outcome after TAVR.

23 June 2025 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
KSKazuki Suruga
Kazuki Suruga
VPVivek Patel
Vivek Patel
TNTakashi Nagasaka
Takashi Nagasaka
YGYuchao Guo
Yuchao Guo
PMPrateek Madaan
Prateek Madaan
RMRaj R. Makkar
Raj R. Makkar

2 March 2020 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
YGYuchao Guo
Yuchao Guo
RLRuifeng Liu
Ruifeng Liu
LCLianfeng Chen
Lianfeng Chen
WWWei Wu
Wei Wu
SZShuyang Zhang
Shuyang Zhang
Background: This study investigated neutrophil activation and neutrophil-derived extracellular traps formation in coronary artery ectasia. Methods: We enrolled 90 patients who underwent coronary angiography, and included 30 patients with coronary artery ectasia (CAE), 30 patients with obstructive coronary artery disease (CAD) and 30 patients with normal coronary arteries (CON). Intra-neutrophil mean myeloperoxidase index (MPXI) was determined using an automated blood cell counter (ADVIA2120 Hematology System). Serum concentrations of plasma adhesion molecules, cytokines, and neutrophil-derived extracellular traps were quantified. Results: The intra-neutrophil mean myeloperoxidase index was reduced in CAE patients compared to CAD and CON patients (1.02 ± 3.01, 3.22 ± 3.03, 3.52 ± 4.25, respectively; CAE vs CAD, p = 0.016 and CAE vs CON, p = 0.007). Multiple logistic regression analysis showed that MPXI and dsDNA were independent factors that predicted the presence of CAE. CAE patients had higher levels of plasma adhesion molecules (P-selectin glycoprotein ligand-1, E-selectin, L-selectin) and interleukin 1 beta levels. Neutrophil extracellular trap concentrations were significantly higher in the CAE group compared to CAD and CON patients (284.31(258.33–449.91) ng/mL, 225.12(203.34–257.13) ng/mL, and 247.37(231.04–273.01) ng/mL, respectively; CAE vs CAD, p = 0.000 and CAE vs CON, p = 0.001). Conclusions: Peripheral neutrophils from CAE patients were activated and neutrophil extracellular traps were elevated in the plasma. IL-1β and soluble adhesion molecules may be the causal factors for neutrophil activation.

19 July 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JFJiaqi Fan
Jiaqi Fan
HDHanyi Dai
Hanyi Dai
YGYuchao Guo
Yuchao Guo
JXJianguo Xu
Jianguo Xu
LWLihan Wang
Lihan Wang
JWJian’an Wang
Jian’an Wang
Background: There are limited data available on the development of arrhythmias in patients at risk of high-degree atrioventricular block (HAVB) or complete heart block (CHB) following transcatheter aortic valve replacement (TAVR). Objective: This study aimed to explore the incidence and evolution of arrhythmias by monitoring patients at risk of HAVB or CHB after TAVR using smartwatches. Methods: We analyzed 188 consecutive patients in the prospective SMART TAVR (smartwatch-facilitated early discharge in patients undergoing TAVR) trial. Patients were divided into 2 groups according to the risk of HAVB or CHB. Patients were required to trigger a single-lead electrocardiogram (ECG) recording and send it to the Heart Health App via their smartphone. Physicians in the central ECG core lab would then analyze the ECG. The incidence and timing of arrhythmias and pacemaker implantation within a 30-day follow-up were compared. All arrhythmic events were adjudicated in a central ECG core lab. Results: The mean age of the patients was 73.1 (SD 7.3) years, of whom 105 (55.9%) were men. The mean discharge day after TAVR was 2.0 (SD 1.8) days. There were no statistically significant changes in the evolution of atrial fibrillation or atrial flutter, Mobitz I, Mobitz II, and third-degree atrial ventricular block over time in the first month after TAVR. The incidence of the left bundle branch block (LBBB) increased in the first week and decreased in the subsequent 3 weeks significantly (P<.001). Patients at higher risk of HAVB or CHB received more pacemaker implantation after discharge (n=8, 9.6% vs n=2, 1.9%; P=.04). The incidence of LBBB was higher in the group with higher HAVB or CHB risk (n=47, 56.6% vs n=34, 32.4%; P=.001). The independent predictors for pacemaker implantation were age, baseline atrial fibrillation, baseline right bundle branch block, Mobitz II, and third-degree atrioventricular block detected by the smartwatch. Conclusions: Except for LBBB, no change in arrhythmias was observed over time in the first month after TAVR. A higher incidence of pacemaker implantation after discharge was observed in patients at risk of HAVB or CHB. However, Mobitz II and third-degree atrioventricular block detected by the smartwatch during follow-ups were more valuable indicators to predict pacemaker implantation after discharge from the index TAVR. Trial Registration: ClinicalTrials.gov NCT04454177; https://clinicaltrials.gov/study/NCT04454177

22 May 2018 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
WWWei Wu
Wei Wu
SZShuyang Zhang
Shuyang Zhang
YGYuchao Guo
Yuchao Guo
RLRuifeng Liu
Ruifeng Liu
ZSZhujun Shen
Zhujun Shen
ZLZhenyu Liu
Zhenyu Liu
The precise relationship between increased thrombolysis in myocardial infarction (TIMI) frame counts and the topographical extent of isolated coronary artery ectasia (CAE) has not been fully explained. New parameters of linear dimension (LD) and the estimated ectatic area (EEA) together with the diameter and ectasia ratio may be associated with the corrected TIMI frame count (CTFC) in isolated CAE patients. The topographical parameters of ectatic coronary arteries and/or segments of 77 isolated CAE patients were consecutively studied. The CTFC for each coronary artery was determined by angiographic frame count. Right coronary artery (RCA) was the most frequently affected. The RCA and left circumflex (LCX) had significantly longer LD (p < 0.001 for both), and greater EEA (p < 0.001 for both) than those of left anterior descending artery (LAD). Similarly, the RCA and LCX have higher CTFCs (p = 0.001 and p = 0.008, respectively) than LAD. All topographic parameters and CTFCs were positively correlated with Markis classification. Linear regression analyses revealed that CTFCs were strongly correlated with diameter, LD, ectasia ratio and EEA, while EEA was the best predictor for the CTFC. Among multiple linear and nonlinear regression models, the cubic model between the CTFC and EEA exhibits the best Goodness-of-Fit. The severity of the topographical extent of CAE was significantly correlated with increased CTFCs. Both the linear dimension and ectatic diameter (combined as EEA) were important for evaluating decreased coronary flow in isolated CAE patients.