Carmen Lopez-de-la-Fuente

Dr. Carmen Lopez-de-la-Fuente

Física Aplicada, Universidad de Zaragoza, Zaragoza, Aragon, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
ASAna Sanchez-Cano
Ana Sanchez-Cano
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
FSFrancisco Segura
Francisco Segura
CLCarmen Lopez-de-la-Fuente
Carmen Lopez-de-la-Fuente
NCNicolás Cuenca
Nicolás Cuenca
Isabel PinillaIsabel Pinilla
Isabel Pinilla

1 January 2016 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
CLCarmen Lopez-de-la-Fuente
Carmen Lopez-de-la-Fuente
ASAna Sanchez-Cano
Ana Sanchez-Cano
FSFrancisco Segura
Francisco Segura
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
Isabel PinillaIsabel Pinilla
Isabel Pinilla
PURPOSE: To evaluate total corneal thickness and corneal layers in healthy young adults using spectral-domain optical coherence tomography and to describe its repeatability and reproducibility. METHODS: Eighty-six eyes from 86 healthy volunteers were prospectively and consecutively enrolled. Manual measurements of central corneal thickness (CCT) and central thickness of epithelium, Bowman's layer, stroma, and the Descemet–endothelium complex were performed using Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). To assess the reliability of the repeated measurements, intraclass correlation coefficients and coefficients of variation were used. RESULTS: Mean CCT, epithelium, Bowman's layer, stroma, and Descemet–endothelium values were 555.50 ± 29.64, 54.60 ± 4.25, 16.70 ± 1.73, 467.51 ± 28.91, and 16.74 ± 1.66 µ m, respectively. The intraclass correlation coefficients ranged from 0.746 (Bowman's layer) to 0.999 (CCT and stroma) and from 0.483 (Bowman's layer) to 0.995 (CCT) and 0.998 (stroma) for intraobserver repeatability and interobserver reproducibility, respectively. The measurements showed coefficients of variation lower than 11% in all cases. CONCLUSIONS: This study establishes a normal database for corneal thickness and all its layers in healthy young adults with spectral-domain optical coherence tomography. This device exhibited a high degree of intraobserver repeatability and interobserver reproducibility for all regions except Bowman's layer. [ J Refract Surg. 2016;32(1):27–32.]

1 January 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CLCarmen Lopez-de-la-Fuente
Carmen Lopez-de-la-Fuente
ASAna Sanchez-Cano
Ana Sanchez-Cano
FSFrancisco Segura
Francisco Segura
Isabel PinillaIsabel Pinilla
Isabel Pinilla
Purpose. To assess the normal values and the repeatability of the Galilei Dual Scheimpflug Analyzer (GDSA), the biometer IOL Master, and the autokerato/refractometer WAM 5500 in anterior segment examinations.Methods. Eighty-eight eyes from 88 healthy volunteers were prospectively and consecutively recruited. The repeatability was assessed, calculating the intraclass correlation coefficient (ICC).Results. The correlations among the repeated measurements showed nearly perfect reliability (ICC > 0.81) for all of the parameters, except corneal astigmatism Galilei (0.79) and WAM (0.68). There were statistically significant differences (P<0.001) between the values of the flat simulated keratometry (SimK) and the steep SimK measured by GDSA and the other methods; however, there were no statistically significant differences for the values obtained with the IOL Master and WAM 5500 (P=0.302andP=0.172, resp.) or between the values of the ACD (P<0.001) and WTW (P=0.007) measured by the IOL Master and GDSA.Conclusions. The anterior segment measurements from the IOL Master and WAM 5500 were highly repeatable, comparable, and well correlated. In healthy young persons, the evaluated parameters had very good repeatability, although significant differences were found between the GDSA and IOL Master and between the GDSA and WAM 5500.

13 March 2023 in Life
Verified
Journal Article
Open access
PDF file
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
ANAitana Navarro
Aitana Navarro
CLCarmen Lopez-de-la-Fuente
Carmen Lopez-de-la-Fuente
ASAna Sanchez-Cano
Ana Sanchez-Cano
Background: The purpose of this study was to evaluate ocular motility in normal young adults when performing the Developmental Eye Movement (DEM) test using an infrared eye-tracker in a sample of young subjects without visual dysfunctions. Methods: An optometric evaluation was carried out on 52 participants with a mean age of 21.00 ± 3.22 years to verify they did not have any binocular dysfunction, by completing a computerized version of the DEM test while their eye movements were recorded with an eye-tracker. A custom-written software was developed to analyse some specific parameters of ocular motility while performing each subtest (Test A, Test B and Test C) of the complete DEM test. Results: The mean duration of the fixations was shorter in Test C (243.56 ± 46.18 s) than in Test A (493.52 ± 171.41 s) and Test B (484.20 ± 156.59 s). The mean adjusted horizontal (AdjHT: 35.24 ± 6.68 s) and vertical (VT: 33.58 ± 5.56 s) times were at the 45th and at the 40th percentile, respectively. In Test C, there was a high positive significant correlation between the saccadic speed (cc: 0.77; p < 0.001) and the saccadic length (cc: 0.74; p < 0.001) of both eyes. Conclusions: The eye-tracker is an objective method to evaluate the DEM test in subjects without binocular dysfunctions, measuring and quantifying ocular motility parameters that are impossible with the traditional subjective method. The eye movements of both eyes are conjugated in each subject, having saccades of the same length and speed.

28 February 2023 in Life
Verified
Journal Article
Open access
PDF file
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
LOLuz Maurain Orera
Luz Maurain Orera
CLCarmen Lopez-de-la-Fuente
Carmen Lopez-de-la-Fuente
ASAna Sanchez-Cano
Ana Sanchez-Cano
Background: To objectively measure with an eye tracker both eye movement conjugacy and gaze direction in different positions when performing the Hess Lancaster Screen Test (HLST) in a sample of control subjects without binocular dysfunction and compare the results with those of the traditional subjective HLST performance. Methods: The sample was selected avoiding subjects who suffered from suppression of one of the two eyes, visual acuity less than 20/25 on the Snellen chart in each eye, strabismus, or any symptom of binocular dysfunction that could alter the results. While performing the HLST, the examiner wrote down each of the points on a template in a traditional way while the eye tracker (Tobii Pro Fusion, Tobii AB, Danderyd, Sweden), placed in front of the subject, took objective measurements of the position of both eyes at each point. Of the 29 subjects recruited in this study, 13 subjects between 18 and 27 years old underwent the complete optometric examination and the HLST wearing anaglyph glasses; meanwhile, 16 people were excluded because of binocular or accommodative dysfunctions or because they didn’t give reliable eye-tracking results. Additionally, a specific program called Etracker Parse Video (University of Zaragoza, Zaragoza, Spain) was developed to analyse the prismatic deviation between both eyes at each evaluated point. Results: Similar horizontal prismatic deviations of visual axes were obtained in the different gaze positions with the Maddox rod, the manually annotated HLST, and the eye-tracker measurement. Variations were found in the magnitude of the deviation between methods but not in the direction. On the other hand, vertical deviations were more difficult for the examiner to detect and quantify, especially those with small magnitudes; more exact values were obtained when measuring objectively with the eye tracker. Conclusion: The HLST is very useful and allows the amount of heterophoria or heterotropia to be recorded in the patient’s medical record in all the main gaze positions. This test is complementary; by itself, it is not diagnostic and does not replace a complete examination of binocular vision. The eye tracker is an objective method with which we can evaluate the HLST in patients with no binocular problems, obtaining more accurate results than when it is performed in the traditional manner.

1 January 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CLCarmen Lopez-de-la-Fuente
Carmen Lopez-de-la-Fuente
ASAna Sanchez-Cano
Ana Sanchez-Cano
FSFrancisco Segura
Francisco Segura
Lorena Fuentes-BrotoLorena Fuentes-Broto
Lorena Fuentes-Broto
Isabel PinillaIsabel Pinilla
Isabel Pinilla
Purpose. To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination.Methods. Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calculating intraclass correlation coefficient (ICC), and coefficient of variation (COV).Results. Correlation among repeated measurements showed almost perfect reliability (ICC > 0.81) for all parameters except thinnest central corneal thickness (CCT) (0.78), corneal thickness average out (0.79), and posterior axial curvature average out (0.60). Repeatability was excellent (COV<10%) for all parameters except anterior chamber volume and, superior iridocorneal angle and eccentricities. In these last three parameters, repeatability limits were excessively high compared to the mean.Conclusions. GDSA in healthy young persons had an almost perfect correlation in measuring anatomic, axial, instantaneous, and refractive parameters with greater variability for peripheral terms. Repeatability of anatomical parameters like pachymetry, anterior chamber, or iridocorneal angle and eccentricity were limited. In healthy young persons, the other evaluated parameters had very good repeatability and their limits of agreement showed excellent clinical results for this device.