This paper provides a rigorous analysis on the measurement of the permittivity of two-dimensional anisotropic biological tissues such as skeletal muscle using the four-electrode impedance technique. The state-of-the-art technique requires individual electrodes placed at the same depth in contact with the anisotropic material, e.g. using monopolar needles. In this case, the minimum of measurements in different directions needed to estimate the complex permittivity and its anisotropy direction is 3, which translates into 12 monopolar needle insertions (i.e. 3 directions × 4 electrodes in each direction). Here, we extend our previous work and equip the reader with 8 new methods for multipolar needles, where 2 or more electrodes are spaced along the needle’s shaft in contact with the tissue at different depths. Using multipolar needles, the new methods presented reduce the number of needle insertions by a factor of 2 with respect to the available methods. We illustrate the methods with numerical simulations and new experiments on ex vivo ovine skeletal muscle (n = 3). Multi-frequency longitudinal and transverse permittivity data from 30 kHz to 1 MHz is made publicly available in the supplementary material. The methods presented here for multipolar needles bring closer the application of needle electrical impedance to patients with neuromuscular diseases.
1 January 2013 in Computational and Mathematical Methods in Medicine
The electrical properties of biological tissues can be described by a complex tensor comprising a simple expression of the effective admittivity. The effective admittivities of biological tissues depend on scale, applied frequency, proportions of extra- and intracellular fluids, and membrane structures. The effective admittivity spectra of biological tissue can be used as a means of characterizing tissue structural information relating to the biological cell suspensions, and therefore measuring the frequency-dependent effective conductivity is important for understanding tissue’s physiological conditions and structure. Although the concept of effective admittivity has been used widely, it seems that its precise definition has been overlooked. We consider how we can determine the effective admittivity for a cube-shaped object with several different biologically relevant compositions. These precise definitions of effective admittivity may suggest the ways of measuring it from boundary current and voltage data. As in the homogenization theory, the effective admittivity can be computed from pointwise admittivity by solving Maxwell equations. We compute the effective admittivity of simple models as a function of frequency to obtain Maxwell-Wagner interface effects and Debye relaxation starting from mathematical formulations. Finally, layer potentials are used to obtain the Maxwell-Wagner-Fricke expression for a dilute suspension of ellipses and membrane-covered spheres.
Magnetic resonance electric properties tomography (MREPT) is a recent medical imaging modality for visualizing the electrical tissue properties of the human body using radio-frequency magnetic fields. It uses the fact that in magnetic resonance imaging (MRI) systems the eddy currents induced by the radio-frequency magnetic fields reflect the conductivity (σ) and permittivity distributions inside the tissues through Maxwell's equations. The corresponding inverse problem consists of reconstructing the admittivity distribution at the Larmor frequency ( MHz for a 3 Tesla MRI machine) from the positive circularly polarized component of the magnetic field . Previous methods are usually based on an assumption of local homogeneity which simplifies the governing equation. However, previous methods that include the assumption of homogeneity are prone to artifacts in the region where γ varies. Hence, recent work has sought a reconstruction method that does not assume local-homogeneity. This paper presents a new MREPT reconstruction method which does not require any local homogeneity assumption on γ. We find that γ is a solution of a semi-elliptic partial differential equation with its coefficients depending only on the measured data , which enable us to compute a blurred version of γ. To improve the resolution of the reconstructed image, we developed a new optimization algorithm that minimizes the mismatch between the data and the model data as a highly nonlinear function of γ. Numerical simulations are presented to illustrate the potential of the proposed reconstruction method.
1 January 2013 in Computational and Mathematical Methods in Medicine
Electrical Impedance Tomography (EIT) is a very attractive functional imaging method despite the low sensitivity and resolution. The use of internal electrodes with the conventional reconstruction algorithms was not enough to enhance image resolution and accuracy in the region of interest (ROI). We propose a local ROI imaging method with internal electrodes developed from careful analysis of the sensitivity matrix that is designed to reduce the sensitivity of the voxels outside the local region and optimize the sensitivity of the voxel inside the local region. We perform numerical simulations and physical measurements to demonstrate the localized EIT imaging method. In preliminary results with multiple objects we show the benefits of using an internal electrode and the improved resolution due to the local ROI image reconstruction method. The sensitivity is further increased by allowing the surface electrodes to be unevenly spaced with a higher density of surface electrodes near the ROI. Also, we analyse how much the image quality is improved using several performance parameters for comparison. While these have not yet been studied in depth, it convincingly shows an improvement in local sensitivity in images obtained with an internal electrode in comparison to a standard reconstruction method.
16 June 2014 in Measurement Science and Technology
This paper presents bioimpedance spectroscopy measurements of anisotropic tissues using a 16 electrode probe and reconstruction method of estimating the anisotropic impedance spectrum in a local region just underneath the center of the probe. This may enable in-vivo surface bioimpedance measurements with similar performance to the ex-vivo gold standard that requires excising and placing the entire tissue sample in a unit measurement cell with uniform electric field. The multiple surface electrodes enable us to create a focused current pattern so that the resulting measured voltage is more sensitive to a local region and less sensitive to other areas. This is exploited in a reconstruction method to provide improved bioimpedance and anisotropy measurements. In this paper, we describe the current pattern for localized electrical energy concentration, performance with the spring loaded pin electrodes, data calibration and experimental results on anisotropic agar phantoms and different tissue types. The anisotropic conductivity spectra are able to differentiate insulating films of different thickness and detect their orientation. Bioimpedance spectra of biological tissues are in agreement with published data and reference instruments. The anisotropy expressed as the ratio of eigenvalues and the orientation of eigenfunctions were reconstructed at 45° intervals. This information is used to predict the underlying anisotropy of the region under the probe. Tissue measurements clearly demonstrate the expected higher anisotropy of muscle tissue compared to liver tissue and spectral changes.
OBJECTIVE: The neurology and physiatry community need improved tools for the evaluation of skeletal muscle condition. Here, we evaluate needle electrical impedance myography (EIM), a new minimally invasive approach to determine muscle status that could ultimately become a bedside tool for the assessment of neuromuscular disorders. APPROACH: We design and study the recording characteristics of tetrapolar EIM needle electrodes combining theory and finite element model simulations. We then use these results to build and pilot in-vivo an EIM needle electrode in the rat gastrocnemius muscle (n = 2). The dielectric properties of muscle are reported (mean ± standard deviation). RESULTS: The numerical simulations show the contribution of subcutaneous fat and muscle tissues to needle EIM data is 97%, respectively; and the sensed volume is 0.70 cm3. Apparent resistivity 277 ± 30 Ωcm and relative permittivity (1 ± 0.4) 105 (dimensionless) measured at 10 kHz are in good agreement with in-vivo dielectric properties reported in the literature. SIGNIFICANCE: The results presented show the feasibility of measuring muscle impedivity in-vivo using a needle electrode from 10 kHz to 1 MHz. The development of needle EIM technology can open up a new field of study in electrodiagnostic medicine, with potential applications to both disease diagnosis and biomarker assessment of therapy.