Point-of-care testing methods for the rapid and sensitive screening of pathogenic bacteria are urgently needed because of the high number of outbreaks of microbial infections and foodborne diseases. In this study, we developed a highly sensitive and multiplex lateral flow assay (LFA) for the simultaneous detection of Pseudomonas aeruginosa and Salmonella typhimurium in complex samples by using wheat germ agglutinin (WGA)-modified magnetic quantum dots (Mag@QDs) as a universal detection nanoprobe. The Mag@QDs-WGA tag with a 200 nm Fe3O4 core and multiple QD-formed shell was introduced into the LFA biosensor for the universal capture of the two target bacteria and provided the dual amplification effect of fluorescence enhancement and magnetic enrichment for ultra-sensitivity detection. Meanwhile, two antibacterial antibodies were separately sprayed onto the two test lines of the LFA strip to ensure the specific identification of P. aeruginosa and S. typhimurium through one test. The proposed LFA exhibited excellent analytical performance, including high capture rate (>80%) to the target pathogens, low detection limit (<30 cells/mL), short testing time (<35 min), and good reproducibility (relative standard deviation < 10.4%). Given these merits, the Mag@QDs-WGA-based LFA has a great potential for the on-site and real-time diagnosis of bacterial samples.
This study established a portable and ultrasensitive detection method based on recombinase polymerase amplification (RPA) combined with high-sensitivity multilayer quantum dot (MQD)-based immunochromatographic assay (ICA) to detect the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The RPA-MQD-based ICA method is reported for the first time and has the following advantages: (i) RPA is free from the constraints of instruments and can be promoted in point-of-care testing (POCT) scenarios, (ii) fluorescence ICA enhances the portability of detection operation so that the entire operation time is controlled within 1 h, and (iii) compared with common colorimetric-based RPA-ICA, the proposed assay used MQD to provide strong and quantifiable fluorescence signal, thus enhancing the detection sensitivity. With this strategy, the proposed RPA-MQD-based ICA can amplify and detect the SARS-CoV-2 nucleic acid on-site with a sensitivity of 2 copies/reaction, which is comparable to the sensitivity of commercial reverse transcription quantitative polymerase chain reaction (RT-qPCR) kits. Moreover, the designed primers did not cross-react with other common respiratory viruses, including adenovirus, influenza virus A, and influenza virus B, suggesting high specificity. Thus, the established portable method can sensitively detect SARS-CoV-2 nucleic acid without relying on equipment, having good application prospects in SARS-CoV-2 detection scenarios under non-lab conditions.