Yong Zhou

Yong Zhou


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Open access
BCBen Cowper
Ben Cowper
XLXiang Li
Xiang Li
LYLei Yu
Lei Yu
YZYong Zhou
Yong Zhou
WFW.H. Fan
W.H. Fan
CRC.M. Rao
C.M. Rao
Recombinant, human, erythropoietin (rhEPO) is a glycoprotein hormone which is prescribed throughout the world to treat anaemia caused by chronic kidney disease or chemotherapy. rhEPO is at the forefront of the recent emergence of biosimilar medicines, with numerous products now available worldwide. Due to its complex glycosylation profile, which has a crucial influence upon biological activity, therapeutic rhEPO preparations must be closely monitored to ensure consistency, safety and efficacy. Here, we have compared twelve rhEPO preparations from eleven manufacturers in China and one in Japan, measuring in vivo biological activity and exploring its relationship with glycosylation through sialic acid content determination, isoform distribution via capillary electrophoresis (CE), O-glycan profiling, and N-glycan mapping using a novel anion-exchange/hydrophilic interaction chromatography-mass spectrometry (AEX/HILIC-MS) approach. We observed differences between glycosylation profiles, including the varying occurrence of sialic acid O-acetylation, extension of N-glycan antennae with N-acetyllactosamine units, and the distribution of sialic acids across multi-antennary structures. The presence of unusually high levels of suspected penta- and hexa-anionic N-glycans in several samples is consistent with elevated rhEPO isoform acidity, which is reflected by slightly elevated in vivo bioactivities. This aside, the observed differences in glycosylation profile do not appear to have a significant influence upon biological activity in mice. Nonetheless, with the continued emergence of biosimilars, the study highlights the importance of monitoring glycosylation profiles in biological medicines, in order to detect and account for divergence between products, as well as the presence of unusual or unexpected glycans.

1 April 2021 in Journal of Chromatography A
Verified
Journal Article
Closed access
XLXiang Li
Xiang Li
LYLei Yu
Lei Yu
XSXinchang Shi
Xinchang Shi
CRChunming Rao
Chunming Rao
YZYong Zhou
Yong Zhou

3 March 2022 in Frontiers in Cellular and Infection Microbiology
Verified
Journal Article
Open access
XQXi Qin
Xi Qin
SLShanhu Li
Shanhu Li
XLXiang Li
Xiang Li
DPDening Pei
Dening Pei
YLYu Liu
Yu Liu
YZYong Zhou
Yong Zhou
Owing to the outbreak of the novel coronavirus (SARS-CoV-2) worldwide at the end of 2019, the development of a SARS-CoV-2 vaccine became an urgent need. In this study, we developed a type 9 adeno-associated virus vectored vaccine candidate expressing a dimeric receptor binding domain (RBD) of the SARS-CoV-2 spike protein (S protein) and evaluated its immunogenicity in a murine model. The vaccine candidate, named AAV9-RBD virus, was constructed by inserting a signal peptide to the N-terminus of two copies of RBD, spaced by a linker, into the genome of a type 9 adeno-associated virus. In vitro assays showed that HeLa cells infected by the recombinant AAV virus expressed high levels of the recombinant RBD protein, mostly found in the cell culture supernatant. The recombinant AAV9-RBD virus was cultured and purified. The genome titer of the purified recombinant AAV9-RBD virus was determined to be 2.4 × 1013 genome copies/mL (GC/mL) by Q-PCR. Balb/c mice were immunized with the virus by intramuscular injection or nasal drip administration. Eight weeks after immunization, neutralizing antibodies against the new coronavirus pseudovirus were detected in the sera of all mice; the mean neutralizing antibody EC50 values were 517.7 ± 292.1 (n=10) and 682.8 ± 454.0 (n=10) in the intramuscular injection group and nasal drip group, respectively. The results of this study showed that the recombinant AAV9-RBD virus may be used for the development of a SARS-CoV-2 vaccine.

28 October 2022 in Pathogens
Verified
Journal Article
Open access
PDF file
GWGuangyu Wang
Guangyu Wang
XYXingsheng Yang
Xingsheng Yang
HDHao Dong
Hao Dong
ZTZhijie Tu
Zhijie Tu
YZYong Zhou
Yong Zhou
SWShengqi Wang
Shengqi Wang
This study established a portable and ultrasensitive detection method based on recombinase polymerase amplification (RPA) combined with high-sensitivity multilayer quantum dot (MQD)-based immunochromatographic assay (ICA) to detect the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The RPA-MQD-based ICA method is reported for the first time and has the following advantages: (i) RPA is free from the constraints of instruments and can be promoted in point-of-care testing (POCT) scenarios, (ii) fluorescence ICA enhances the portability of detection operation so that the entire operation time is controlled within 1 h, and (iii) compared with common colorimetric-based RPA-ICA, the proposed assay used MQD to provide strong and quantifiable fluorescence signal, thus enhancing the detection sensitivity. With this strategy, the proposed RPA-MQD-based ICA can amplify and detect the SARS-CoV-2 nucleic acid on-site with a sensitivity of 2 copies/reaction, which is comparable to the sensitivity of commercial reverse transcription quantitative polymerase chain reaction (RT-qPCR) kits. Moreover, the designed primers did not cross-react with other common respiratory viruses, including adenovirus, influenza virus A, and influenza virus B, suggesting high specificity. Thus, the established portable method can sensitively detect SARS-CoV-2 nucleic acid without relying on equipment, having good application prospects in SARS-CoV-2 detection scenarios under non-lab conditions.

22 June 2024 in Human Gene Therapy
Verified
Journal Article
Closed access
XQXi Qin
Xi Qin
QYQikun Yu
Qikun Yu
XLXiang Li
Xiang Li
WJWei Jiang
Wei Jiang
XSXinchang Shi
Xinchang Shi
CLChenggang Liang
Chenggang Liang
Currently, adeno-associated virus (AAV) is one of the primary gene delivery vectors in gene therapy, facilitating long-term in vivo gene expression. Despite being imperative, it is incredibly challenging to precisely assess AAV particle distribution according to the sedimentation coefficient and identify impurities related to capsid structures. This study performed the systematic methodological validation of quantifying the AAV empty and full capsid ratio. This includes specificity, accuracy, precision, linearity, and parameter variables involving the sedimentation velocity analytical ultracentrifugation (SV-AUC) method. Specifically, SV-AUC differentiated among the empty, partial, full, and high sedimentation coefficient substance (HSCS) AAV particles while evaluating their sedimentation heterogeneity. The intermediate precision analysis of HE (high percentage of empty capsid) and HF (high percentage of full capsid) samples revealed that the specific species percentage, such as empty or full, was more significant than 50%. Moreover, the relative standard deviation (RSD) could be within 5%. Even for empty or partially less than 15%, the RSD could be within 10%. The accuracy recovery rates of empty capsid were between 103.9% and 108.7% across three different mixtures. When the measured percentage of specific species was more significant than 14%, the recovery rate was between 77.9% and 106.6%. Linearity analysis revealed an excellent linear correlation between the empty, partial, and full in the HE samples. The AAV samples with as low as 7.4 × 10 11 cp/mL AAV could be accurately quantified with SV-AUC. The parameter variable analyses revealed that variations in cell alignment significantly affected the overall results. Still, the detection wavelength of 235 nm slightly influenced the empty, partial, and full percentages. Minor detection wavelength changes showed no impact on the sedimentation coefficient of these species. However, the temperature affected the measured sedimentation coefficient. These results validated the SV-AUC method to quantify AAV. This study provides solutions to AAV empty and full capsid ratio quantification challenges and the subsequent basis for calibrating the AAV empty capsid system suitability substance. Because of the AAV structure and potential variability complexity in detection, we jointly calibrated empty capsid system suitability substance with three laboratories to accurately detect the quantitative AAV empty and full capsid ratio. The empty capsid system suitability substance could be used as an external reference to measure the performance of the instrument. The results could be compared with multiple QC (quality control) laboratories based on the AAV vector and calibration accuracy. This is crucial for AUC to be used for QC release and promote gene therapy research worldwide.

5 June 2025 in Molecular Therapy Nucleic Acids
Verified
Journal Article
Open access
GWGuangyu Wang
Guangyu Wang
LYLei Yu
Lei Yu
XQXi Qin
Xi Qin
ZZZexin Zhou
Zexin Zhou
YZYong Zhou
Yong Zhou
CLChenggang Liang
Chenggang Liang
The use of adeno-associated viruses (AAVs) as gene therapy vectors is growing, resulting in a pressing need for efficient, reliable AAV analysis methods. Characterizing AAV critical quality attributes (CQAs), such as the abundance of empty or partially filled capsids, is paramount for developing and producing products with high efficacy, low immunogenicity, and low cost. Available methods include analytical ultracentrifugation (AUC)—considered one of the gold standards of AAV analysis technique—and mass photometry—a newer method based on single-particle light scattering. Mass photometry is a fast, low-cost tool that uses little sample and is suitable for environments requiring good manufacturing practices (GMP) compliance. Here, we assess mass photometry’s performance in AAV characterization by using it to analyze a sample of empty AAVs, to measure proportions of empty vs. partially filled vs. full AAVs, to quantify loading in samples ranging from 100% empty to nearly 100% loaded, and to measure samples containing transgenes of different lengths. Comparing to AUC data where appropriate, we find that the two methods give comparable results. Based on its accuracy, precision, measurement capabilities, and practical advantages (e.g., speed and low cost), we conclude that mass photometry is an ideal AAV analysis tool.