Raffaele De Rosa

Dr. Raffaele De Rosa

Department of Industrial Engineering, University of Naples Federico II, Naples, Campania, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2024 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
LRLuca Romagnuolo
Luca Romagnuolo
Raffaele De RosaRaffaele De Rosa
Raffaele De Rosa
EFEmma Frosina
Emma Frosina
ASAdolfo Senatore
Adolfo Senatore

30 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Raffaele De RosaRaffaele De Rosa
Raffaele De Rosa
LRLuca Romagnuolo
Luca Romagnuolo
Emma FrosinaEmma Frosina
Emma Frosina
LBLuigi Belli
Luigi Belli
ASAdolfo Senatore
Adolfo Senatore
Electrification of the field of transport is one of the key elements needed to reach the targets of greenhouse gas emissions reduction and carbon neutrality planned by the European Green Deal. In the railway sector, the hybrid powertrain solution (diesel–electric) is emerging, especially for non-electrified lines. Electric components, especially battery power systems, need an efficient thermal management system that guarantees the batteries will work within specific temperature ranges and a thermal uniformity between the modules. Therefore, a hydronic balancing needs to be realized between the parallel branches that supply the battery modules, which is often realized by introducing pressure losses in the system. In this paper, a thermal management system for battery modules (BTMS) of a hybrid train has been studied experimentally, to analyze the flow rates in each branch and the pressure losses. Since many branches of this system are built inside the battery box of the hybrid train, flow rate measurements have been conducted by means of an ultrasonic clamp-on flow sensor because of its minimal invasiveness and its ability to be quickly installed without modifying the system layout. Experimental data of flow rate and pressure drop have then been used to validate a lumped parameter model of the system, realized in the Simcenter AMESim® environment. This tool has then been used to find the hydronic balancing condition among all the battery modules; two solutions have been proposed, and a comparison in terms of overall power saved due to the reduction in pressure losses has been performed.

22 November 2024 in Applied Thermal Engineering
Verified
Journal Article
Open access
Raffaele De RosaRaffaele De Rosa
Raffaele De Rosa
Marco BernagozziMarco Bernagozzi
Marco Bernagozzi
Anastasios GeorgoulasAnastasios Georgoulas
Anastasios Georgoulas
LRLuca Romagnuolo
Luca Romagnuolo
Emma FrosinaEmma Frosina
Emma Frosina
ASAdolfo Senatore
Adolfo Senatore

1 December 2022 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
Raffaele De RosaRaffaele De Rosa
Raffaele De Rosa
LBL Belli
L Belli
EFE Frosina
E Frosina
PVP Venanzio
P Venanzio
LRL Romagnuolo
L Romagnuolo
ASA Senatore
A Senatore
For many years the most advanced railway propulsion systems have been based on the use of electric motors. Compared to the other available solutions, these are characterized by greater operating economy and less environmental pollution. In order to operate as efficiently as possible and to guarantee the high standards of electromechanical reliability, these propulsion technologies need adequate cooling systems to operate in controlled temperature conditions. Considering this, the implementation of increasingly accurate and performing simulation models can represent a significant advantage and provide great support in the optimization phase of cooling systems, in terms of reduction of dimensions and weight, rapid and low-cost experimentation, prediction of critical scenarios and choice of the best solution strategies to be taken. In this regard, in the context of the collaboration between the University of Naples Federico II, University of Sannio and the company Hitachi Rail STS S.p.A., several lumped parameter models of power converter cooling systems for railway electric propulsion were developed in the Simcenter AMESim environment. These models allowed to validate specific design choices from thermal and hydraulic perspectives, aimed at higher energy efficiency of the system, and to perform the so-called Last Mile predictive analysis, in order to evaluate the possibility of removing a vehicle from the railway line as consequence of a fault of specific components.

1 December 2023 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
Raffaele De RosaRaffaele De Rosa
Raffaele De Rosa
LRL Romagnuolo
L Romagnuolo
EFE Frosina
E Frosina
ASA Senatore
A Senatore
The thermal management system for power electronics is becoming a key factor in order to guarantee optimal working conditions, efficiency and safety of those components. In the field of liquid-cooled power electronics, the design of an optimal liquid cold plate (LCP) is fundamental to increase the heat transfer, minimizing the maximum temperature and the pressure drop. This work presents an optimization procedure of a finned extruded profile of an LCP for insulated gate bipolar transistor (IGBT) power module, for railway propulsion. The optimization has been performed through DOE, by considering different values of several control factors (shape of the fin, length of the fin, pitch between the channels created by the fins), in order to minimize the LCP maximum temperature and the pressure drop between inlet and outlet. The combination of different values of control factors results in 18 prototypes, which have been compared using three-dimensional CFD simulations, performed in Ansys Fluent environment. The influence of parameters variation on the objective functions (i.e. maximum temperature of the liquid cold plate and pressure drop) has been verified.