Marios Neofytou

Dr. Marios Neofytou


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
VTVasilios Tanos
Vasilios Tanos
MNMarios Neofytou
Marios Neofytou
PTPanayiotis Tanos
Panayiotis Tanos
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
MPMarios Pattichis
Marios Pattichis
This review of our experience in computer-assisted tissue image analysis (CATIA) research shows that significant information can be extracted and used to diagnose and distinguish normal from abnormal endometrium. CATIA enabled the evaluation and differentiation between the benign and malignant endometrium during diagnostic hysteroscopy. The efficacy of texture analysis in the endometrium image during hysteroscopy was examined in 40 women, where 209 normal and 209 abnormal regions of interest (ROIs) were extracted. There was a significant difference between normal and abnormal endometrium for the statistical features (SF) features mean, variance, median, energy and entropy; for the spatial grey-level difference matrix (SGLDM) features contrast, correlation, variance, homogeneity and entropy; and for the gray-level difference statistics (GLDS) features homogeneity, contrast, energy, entropy and mean. We further evaluated 52 hysteroscopic images of 258 normal and 258 abnormal endometrium ROIs, and tissue diagnosis was verified by histopathology after biopsy. The YCrCb color system with SF, SGLDM and GLDS color texture features based on support vector machine (SVM) modeling correctly classified 81% of the cases with a sensitivity and a specificity of 78% and 81%, respectively, for normal and hyperplastic endometrium. New technical and computational advances may improve optical biopsy accuracy and assist in the precision of lesion excision during hysteroscopy. The exchange of knowledge, collaboration, identification of tasks and CATIA method selection strategy will further improve computer-aided diagnosis implementation in the daily practice of hysteroscopy.

1 January 2007 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MNMarios Neofytou
Marios Neofytou
VTVasilios Tanos
Vasilios Tanos
MPMarios Pattichis
Marios Pattichis
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
EKEfthyvoulos Kyriacou
Efthyvoulos Kyriacou
Dimitris Dionissios KoutsourisDimitris Dionissios Koutsouris
Dimitris Dionissios Koutsouris
In the development of tissue classification methods, classifiers rely on significant differences between texture features extracted from normal and abnormal regions. Yet, significant differences can arise due to variations in the image acquisition method. For endoscopic imaging of the endometrium, we propose a standardized image acquisition protocol to eliminate significant statistical differences due to variations in: (i) the distance from the tissue (panoramic vs close up), (ii) difference in viewing angles and (iii) color correction. We investigate texture feature variability for a variety of targets encountered in clinical endoscopy. All images were captured at clinically optimum illumination and focus using 720 × 576 pixels and 24 bits color for: (i) a variety of testing targets from a color palette with a known color distribution, (ii) different viewing angles, (iv) two different distances from a calf endometrial and from a chicken cavity. Also, human images from the endometrium were captured and analysed. For texture feature analysis, three different sets were considered: (i) Statistical Features (SF), (ii) Spatial Gray Level Dependence Matrices (SGLDM), and (iii) Gray Level Difference Statistics (GLDS). All images were gamma corrected and the extracted texture feature values were compared against the texture feature values extracted from the uncorrected images. Statistical tests were applied to compare images from different viewing conditions so as to determine any significant differences. For the proposed acquisition procedure, results indicate that there is no significant difference in texture features between the panoramic and close up views and between angles. For a calibrated target image, gamma correction provided an acquired image that was a significantly better approximation to the original target image. In turn, this implies that the texture features extracted from the corrected images provided for better approximations to the original images. Within the proposed protocol, for human ROIs, we have found that there is a large number of texture features that showed significant differences between normal and abnormal endometrium. This study provides a standardized protocol for avoiding any significant texture feature differences that may arise due to variability in the acquisition procedure or the lack of color correction. After applying the protocol, we have found that significant differences in texture features will only be due to the fact that the features were extracted from different types of tissue (normal vs abnormal).

1 August 2006
Verified
Conference Paper
Open access
MNMarios Neofytou
Marios Neofytou
MPM. S. Pattichis
M. S. Pattichis
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
VTV. Tanos
V. Tanos
EKEfthyvoulos Kyriacou
Efthyvoulos Kyriacou
Dimitris Dionissios KoutsourisDimitris Dionissios Koutsouris
Dimitris Dionissios Koutsouris
The objective of this study was to classify hysteroscopy images of the endometrium based on texture analysis for the early detection of gynaecological cancer. A total of 418 regions of interest (ROIs) were extracted (209 normal and 209 abnormal) from 40 subjects. Images were gamma corrected and were converted to gray scale. The following texture features were extracted: (i) statistical features, (ii) spatial gray level dependence matrices (SGLDM), and (iii) gray level difference statistics (GLDS). The PNN and SVM neural network classifiers were also investigated for classifying normal and abnormal ROIs. Results show that there is significant difference (using Wilcoxon rank sum test at a=0.05) between the texture features of normal and abnormal ROIs for both the gamma corrected and uncorrected images. Abnormal ROIs had lower gray scale median and homogeneity values, and higher entropy and contrast values when compared to the normal ROIs. The highest percentage of correct classifications score was 77% and was achieved for the SVM models trained with the SF and GLDS features. Concluding, texture features provide useful information differentiating between normal and abnormal ROIs of the endometrium

1 August 2007
Verified
Conference Paper
Open access
MNMarios Neofytou
Marios Neofytou
VTVasilios Tanos
Vasilios Tanos
MPMarios Pattichis
Marios Pattichis
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
EKEfthyvoulos Kyriacou
Efthyvoulos Kyriacou
SPS. Pavlopoulos
S. Pavlopoulos
The objective of this study was to develop a CAD system for the classification of hysteroscopy images of the endometrium based on color texture analysis for the early detection of gynaecological cancer. A total of 416 Regions of Interest (ROIs) of the endometrium were extracted (208 normal and 208 abnormal) from 40 subjects. RGB images were gamma corrected and were converted to the HSV and YCrCb color systems. The following texture features were extracted for each channel of the RGB, HSV, and YCrCb systems: (i) statistical features, (ii) spatial gray level dependence matrices and (iii) gray level difference statistics. The PNN statistical learning and SVM neural network classifiers were also investigated for classifying normal and abnormal ROIs. Results show that there is significant difference (using the Wilcoxon Rank Sum Test at a=0.05) between the texture features of normal and abnormal ROIs of the endometrium. Abnormal ROIs had higher gray scale median, variance, entropy and contrast and lower gray scale median and homogeneity values when compared to the normal ROIs. The highest percentage of correct classifications score was 79 % and was achieved for the SVM models trained with the SF and GLDS features for differentiating between normal and abnormal ROIs. Concluding, a CAD system based on texture analysis and SVM models can be used to classify normal and abnormal endometrium tissue. Further work is needed to validate the system in more cases and organs.

9 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
VTVasilios Tanos
Vasilios Tanos
MNMarios Neofytou
Marios Neofytou
ASAhmed Samy Abdulhady Soliman
Ahmed Samy Abdulhady Soliman
PTPanayiotis Tanos
Panayiotis Tanos
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
Purpose: Computer-assisted tissue image analysis (CATIA) enables an optical biopsy of human tissue during minimally invasive surgery and endoscopy. Thus far, it has been implemented in gastrointestinal, endometrial, and dermatologic examinations that use computational analysis and image texture feature systems. We review and evaluate the impact of in vivo optical biopsies performed by tissue image analysis on the surgeon’s diagnostic ability and sampling precision and investigate how operation complications could be minimized. Methods: We performed a literature search in PubMed, IEEE, Xplore, Elsevier, and Google Scholar, which yielded 28 relevant articles. Our literature review summarizes the available data on CATIA of human tissues and explores the possibilities of computer-assisted early disease diagnoses, including cancer. Results: Hysteroscopic image texture analysis of the endometrium successfully distinguished benign from malignant conditions up to 91% of the time. In dermatologic studies, the accuracy of distinguishing nevi melanoma from benign disease fluctuated from 73% to 81%. Skin biopsies of basal cell carcinoma and melanoma exhibited an accuracy of 92.4%, sensitivity of 99.1%, and specificity of 93.3% and distinguished nonmelanoma and normal lesions from benign precancerous lesions with 91.9% and 82.8% accuracy, respectively. Gastrointestinal and endometrial examinations are still at the experimental phase. Conclusions: CATIA is a promising application for distinguishing normal from abnormal tissues during endoscopic procedures and minimally invasive surgeries. However, the efficacy of computer-assisted diagnostics in distinguishing benign from malignant states is still not well documented. Prospective and randomized studies are needed before CATIA is implemented in clinical practice.

1 August 2006 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Open access
TDT. Dimitrova
T. Dimitrova
LGL. Georgieva
L. Georgieva
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
MNMarios Neofytou
Marios Neofytou
The evaluation of bruise color imaging is a very important task in forensic medicine. However, there is no standardized methodology in carrying out this task. In this paper, an attempt was made to review the different papers published in the literature on the visual assessment of bruise age determination, and derive color charts of daily bruise aging. Based on the color charts derived, the following observations can be made: (i) the bruise is red for day 1, (ii) there is no dominant color for day 2, whereas for day 3, blue is becoming slightly dominant, (iii) green is becoming dominant for days 4-6, with yellow color emerging, (iv) for day 7, there is coexistence of green and yellow, (v) yellow is highly dominant for days 7 to 14, with brown emerging. These charts can serve as guidelines for the qualitative evaluation of bruise imaging by visual analysis. Clearly, the need exists for the quantitative analysis of bruise color imaging