An optimized heat pump control for building heating was developed for minimizing CO emissions from related electrical power generation. The control is using weather and CO emission forecasts as inputs to a Model Predictive Control (MPC)—a multivariate control algorithm using a dynamic process model, constraints and a cost function to be minimized. In a simulation study, the control was applied using weather and power grid conditions during a full-year period in 2017–2018 for the power bidding zone DK2 (East, Denmark). Two scenarios were studied; one with a family house and one with an office building. The buildings were dimensioned based on standards and building codes/regulations. The main results are measured as the CO emission savings relative to a classical thermostatic control. Note that this only measures the gain achieved using the MPC control, that is, the energy flexibility, not the absolute savings. The results show that around 16% of savings could have been achieved during the period in well-insulated new buildings with floor heating. Further, a sensitivity analysis was carried out to evaluate the effect of various building properties, for example, level of insulation and thermal capacity. Danish building codes from 1977 and forward were used as benchmarks for insulation levels. It was shown that both insulation and thermal mass influence the achievable flexibility savings, especially for floor heating. Buildings that comply with building codes later than 1979 could provide flexibility emission savings of around 10%, while buildings that comply with earlier codes provided savings in the range of 0–5% depending on the heating system and thermal mass.
24 September 2022 in International Journal of Electrical Power & Energy Systems
Increasing levels of distributed generation (DG), as well as changes in electricity consumption behavior, are reshaping power distribution systems. These changes might place particular stress on the secondary low-voltage (LV) distribution systems not originally designed for bi-directional power flows. Voltage violations, reverse power flow, and congestion are the main arising concerns for distribution system operators (DSOs), while observability in these grids is typically nonexistent or very low. The present paper addresses this issue by developing a method for nodal voltage estimation in unbalanced radial LV grids (at 0.4 kV). The workflow of the proposed method combines a data-driven grey-box modeling approach with generalized additive models (GAMs). Furthermore, the proposed method relies on experimental data from a real-world LV grid in Denmark and uses data input from only one measuring device per feeder. Predictions are evaluated by using a test data set of 31 days, which is more than twice the size of the training data set of 13 days. The prediction results show high accuracy at root mean squared errors (RMSEs) of 0.002–0.0004 p.u. The method also requires a short computation time (14 s for the first stage and 2 s for the second stage) that meets requirements for the practical, real-time monitoring of DSO grids.
28 December 2023 in International Journal of Electrical Power & Energy Systems