A constant power supply is a basic need for each consumer due to the increase in sensitive equipment day by day. As per IEEE standards, a 10% reduction in voltage from the supply voltage is not acceptable and may cause the failure of equipment. Previously, different techniques have been used to alleviate the voltage sag, such as STATCOM, DSTATCOM, SVC, and shunt capacitors, but these devices are connected in parallel, which compensates for the low value of voltage sag, and they have high maintenance costs involved. Compensation for the low and high values of voltage sag is possible through a series-connected device such as a dynamic voltage restorer. In this paper, a matrix converter is presented for DVR to convert AC to AC voltage directly and free from batteries, capacitors, and multiple conversions as needed in a voltage source inverter, resulting in a reduced cost of DVR topology. The DVR is meaningless in the absence of a controller, so it is necessary to select a suitable controller for the satisfactory operation of the DVR under a variation of system parameters. In this paper, the performance of a linear PID controller is analyzed and compared with a nonlinear controller, such as a sliding-mode controller, under variation of power system parameters inorder to select a robust controller that performs satisfactorily for DVR. Earlier trial-and-error methods were used to obtain the parameters of PID gains, but they require a large time to obtain the parameters of the PID gains and there is a chance of inaccuracy. A genetic algorithm was used to obtain the gain parameters, but it has more convergence time and the particle swarm optimization technique has involves less reliability. In this research paper, the sliding surface coefficient parameters such as and Ki for the PI sliding surface of SMC and PID gains are taken through an ant colony algorithm to obtain the robustness of the controllers. The purpose of this paper is to introduce the best DVR topology with reduced cost. MATLAB simulation software was utilized to analyze the performance of the DVR with PID and SMC controllers under different fault conditions and also the THD% of proposed controllers was analyzed through FFT.
27 December 2024 in Sir Syed University Research Journal of Engineering & Technology
Problems related to voltage sags in distribution systems of electrical power add a number of challenges to the efficient performance of sensitive loads, hence the need for mitigation. The Dynamic Voltage Restorer (DVR) is a specialized device designed to counteract both low and high levels of voltage sags by being connected in series with the load. This paper introduces an application of a three-phase Matrix Converter for DVRs, which is capable of direct AC-AC power conversion without the need for an energy storage component. Motivated by the need for efficient and responsive voltage sag correction, a sliding mode controller with a Proportional-Integral sliding surface and hysteresis control is proposed. The traditional methods such as the real-coded genetic algorithm were considered but, these methods typically involve extended convergence times to optimize the PI gains of the Sliding Mode Control (SMC). To this effect, the Ant Colony Optimization (ACO) technique was used and generated the best values of PI gains of 6.87688 and 0.850851. The effectiveness of the SMC was tested under fault conditions and varying load scenarios using MATLAB simulation software, demonstrating satisfactory performance and stabilization at the onset of voltage sags. The DVR's performance, empowered by the Matrix Converter with the SMC framework, has been thoroughly analyzed, and the THD% was further scrutinized using the Fast Fourier Transform (FFT). This research confirms the Matrix Converter integrated with SMC as a robust solution for dynamic voltage restoration, providing a promising avenue for enhancing power quality in modern electrical distribution networks.
28 June 2023 in Sir Syed University Research Journal of Engineering & Technology
A new design of three phase modified matrix converter based on use of fewer semiconductor switches has been introduced in this study with an aim of improving efficiency, simplify circuit architecture and reduced overall cost of implementation. Traditional direct matrix converters (DMCs) typically need 18 bidirectional switches and net result is complicated control programs and elevated losses of power. Reduced-switch topology conversion of AC to AC will save the DC intermediate link in the architecture and simplifies the architecture, offering higher reliability. With a low number of active components, the design is capable of less switching losses and complexity of hardware. The different converters proposed, standard voltage source inverters (VSIs), current source inverters (CSIs), and typical DMCs are thoroughly compared. The key performance indicator total harmonic distortion (THD), system efficiency, control complexity. Simulation results show that the new structure has the same level of performance as the current solutions but possesses all the major benefits of compactness and ease of management, which makes it applicable in motor drives, renewable systems, and other space-limited applications.
29 June 2025 in Sir Syed University Research Journal of Engineering & Technology
The project establishes automatic day-to-night light control through the combination of Passive Infrared (PIR) sensors and Solid State Relays (SSR) devices. The program uses PIR sensors to sense human presence which causes the automatic lighting activation. Through its operation, the system deploys photo sensors which enable it to detect outdoor light conditions and subsequently deactivate the lights for energy conservation purposes. Moving humans inside the monitored space will activate the SSR through PIR sensor detection which will power up the light. The microcontroller handles the sensor data to decide whether to activate or stop the light operation. The system controls the lights through a logic that turns them off when daytime ambient light levels achieve certain thresholds. The power efficiency of the proposed system occurs due to its ability to activate illumination units only during required times. This design proves cost-effective to other solutions because it removes the requirement for a manual switch. The system which historically operated for residential purposes has undergone factory adaptation to save electricity for elderly persons at home and masons operating outside of factory premises. The automatic switch system represents an easy method for detecting daytime and nighttime conditions which can decrease energy usage within homes and businesses through its automated lighting capabilities