Tzu Kang Lin

Dr. Tzu Kang Lin

Department of Civil Engineering, National Chiao Tung University
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Measurement
Verified
Journal Article
Closed access
Chia-Ming ChangChia-Ming Chang
Chia-Ming Chang
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
CCChih-Wei Chang
Chih-Wei Chang

1 November 2016 in Engineering Structures
Verified
Journal Article
Closed access
YSYu-Chi Sung
Yu-Chi Sung
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
YCYi-Tsung Chiu
Yi-Tsung Chiu
KCKuo-Chun Chang
Kuo-Chun Chang
KCKuo-Long Chen
Kuo-Long Chen
CCChung-Ching Chang
Chung-Ching Chang

17 July 2007 in Smart Materials and Structures
Verified
Journal Article
Closed access
DSDavid Shook
David Shook
PLPei-Yang Lin
Pei-Yang Lin
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
PRPaul N Roschke
Paul N Roschke

20 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YLYung-Bin Lin
Yung-Bin Lin
FLFong-Zuo Lee
Fong-Zuo Lee
Kuo-Chun ChangKuo-Chun Chang
Kuo-Chun Chang
Jihn-Sung LaiJihn-Sung Lai
Jihn-Sung Lai
SLShi-Wei Lo
Shi-Wei Lo
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
Scour around bridge piers remains the leading cause of bridge failure induced in flood. Floods and torrential rains erode riverbeds and damage cross-river structures, causing bridge collapse and a severe threat to property and life. Reductions in bridge-safety capacity need to be monitored during flood periods to protect the traveling public. In the present study, a scour monitoring system designed with vibration-based arrayed sensors consisting of a combination of Internet of Things (IoT) and artificial intelligence (AI) is developed and implemented to obtain real-time scour depth measurements. These vibration-based micro-electro-mechanical systems (MEMS) sensors are packaged in a waterproof stainless steel ball within a rebar cage to resist a harsh environment in floods. The floodwater-level changes around the bridge pier are performed using real-time CCTV images by the Mask R-CNN deep learning model. The scour-depth evolution is simulated using the hydrodynamic model with the selected local scour formulas and the sediment transport equation. The laboratory and field measurement results demonstrated the success of the early warning system for monitoring the real-time bridge scour-depth evolution.

1 January 2018 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
LLLyan-Ywan Lu
Lyan-Ywan Lu
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
RJRong-Jie Jheng
Rong-Jie Jheng
HWHsin-Hsien Wu
Hsin-Hsien Wu

30 June 2015 in Smart Materials and Structures
Verified
Journal Article
Closed access
Tzu Kang LinTzu Kang Lin
Tzu Kang Lin
JLJui-Chang Liang
Jui-Chang Liang
This study proposes an information-theoretic structural health monitoring (SHM) system based on multi-scale entropy (MSE) and multi-scale cross-sample entropy (MSCE). By measuring the ambient vibration signal from a structure, the damage condition can be rapidly evaluated via MSE analysis. The damage location can then be detected by analyzing the signals of different floors under the same damage condition via MSCE analysis. Moreover, a damage index is proposed to efficiently quantify the SHM process. Unlike some existing SHM methods, no experimental database or numerical model is required. Instead, a reference measurement of the current stage can initiate and launch the SHM system. A numerical simulation of a four-story steel structure is used to verify that the damage location and condition can be detected by the proposed SHM algorithm, and the location can be efficiently quantified by the damage index. A seven-story scaled-down benchmark structure is then employed for experimental verification. Based on the results, the damage condition can be correctly assessed, and average accuracy rates of 63.4 and 86.6% for the damage location can be achieved using the MSCE and damage index methods, respectively. As only the ambient vibration signal is required with a set of initial reference measurements, the proposed SHM system can be implemented practically with low cost.