Jae-Do Kang

Dr. Jae-Do Kang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
JKJae-Do Kang
Jae-Do Kang
Hiroshi TagawaHiroshi Tagawa
Hiroshi Tagawa

7 July 2023 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
AJAntonio Janevski
Antonio Janevski
JKJae-Do Kang
Jae-Do Kang
TITatjana Isaković
Tatjana Isaković
The capabilities of certain standard macro numerical models were evaluated by simulating a shaking table experiment that was performed on a full-scale ten-storey fixed-base building with a frame and dual structural system in two perpendicular directions (denoted as the frame and wall directions) at the largest shaking table in the E-Defense centre in Japan. The lumped plasticity model for columns and beams, the multiple-vertical-line-element model for walls and the scissors model for beam-column joints were evaluated. The results indicated that the experiment was simulated reasonably well. The most significant discrepancy was observed between the maximum drifts along the wall direction in the strongest cycle of the strongest test (calculated drift of 1.9% versus measured drift of 1.5%). In other cycles and tests, these differences were smaller. The calculated and measured maximum accelerations along the wall direction in the strongest test were 13.8 m/s 2 and 13.5 m/s 2 , respectively. The discrepancy between the analysis and experiment results was smaller along the frame direction. The maximum calculated and measured drifts were 2.9% and 3.1%, respectively. The maximum calculated and measured accelerations were 15.8 m/s 2 and 19.0 m/s 2 , respectively. In general, the standard input parameters were used in the evaluated models. However, some parameters required modifications, particularly when modelling weakly reinforced beam-column joints with substandard reinforcement that were considerably damaged. Their yielding rotation and near-collapse strength were, on average, reduced to 55% and 30% of the standard value, respectively. One of the most important parameters influencing the response was the effective width of the slabs, which was increased to the total span length for the highly loaded beams. The ratios of the strength, stiffness and amount of dissipated energy in the joints, beams and columns also significantly influenced the response. The adequate ratio of the dissipated energy was obtained by reducing the standard unloading stiffness in the beams and columns. The initial stiffness considerably influenced the response, particularly under weaker excitations. This stiffness was reduced threefold to account for various factors that typically reduce its value, which, among others, includes the influence of preceding tests on the same building with sliding foundations, as well as the assembly, transportation and handling of the specimen.

27 April 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JKJae-Do Kang
Jae-Do Kang
YMYasuhiro Mori
Yasuhiro Mori
In this paper, a simplified method is proposed to estimate the peak inter-story drift ratios of steel frames with hysteretic dampers. The simplified method involved the following: (1) the inelastic spectral displacement is estimated using a single-degree-of-freedom (SDOF) system with multi-springs, which is equivalent to a steel frame with dampers and in which multi-springs represent the hysteretic behavior of dampers; (2) the first inelastic mode vector is estimated using a pattern of story drifts obtained from nonlinear static pushover analysis; and (3) the effects of modes higher than the first mode are estimated by using the jth modal period, jth mode vector, and jth modal damping ratio obtained from eigenvalue analysis. The accuracy of the simplified method is estimated using the results of nonlinear time history analysis (NTHA) on a series of three-story, six-story, and twelve-story steel moment resisting frames with steel hysteretic dampers. Based on the results of a comparison of the peak inter-story drift ratios estimated by the simplified method and that computed via NTHA using an elaborate analytical model, the accuracy of the simplified method is sufficient for evaluating seismic demands.

31 July 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
HHHwang Heejin
Hwang Heejin
KOKeunyeong Oh
Keunyeong Oh
ICInsub Choi
Insub Choi
JKJae-Do Kang
Jae-Do Kang
JSJiuk Shin
Jiuk Shin
Existing reinforced concrete building structures have low lateral resistance capacities due to seismically deficient details. Since these building structures suffer an increase in axial loads to the main structural elements due to green retrofits (e.g., installation of energy equipment/devices, roof gardens) as one of the sustainable building solutions and/or vertical extensions, their capacities can be reduced. This paper aims to propose a rapid estimation method incorporating a previously developed machine-learning model to find an allowable range of axial loads for reinforced concrete columns using simple structural details for enhancement in the sustainability performance of existing buildings in structural and energy fields. The methodology consists of two steps: (1) a machine-learning-based failure detection model, and (2) column damage limits proposed by previous researchers. To demonstrate this proposed method, an existing building structure built in the 1990s was selected, and the allowable range for the target structure was computed for both exterior and interior columns. A machine-learning-based method showed that axial loading could be increased by a factor of 1.35. Additionally, nonlinear time-history analysis for the target structure was performed to compare the seismic responses before and after applying the maximum allowable axial load. Based on the dynamic responses, the increased axial loads from green retrofits and/or vertical extensions could degrade structural performance and change its failure mode. The proposed methodology can rapidly estimate the allowable axial load range for existing reinforced concrete buildings without repeated modeling and computing processes. In addition, nonlinear time-history analysis is needed to accurately evaluate the impact of the increased axial loads from green retrofits/vertical extensions on structural performance.

16 July 2023 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
JKJae-Do Kang
Jae-Do Kang
KKKoichi Kajiwara
Koichi Kajiwara
TNTakuya Nagae
Takuya Nagae
ESEiji Sato
Eiji Sato
YTYusuke Tosauchi
Yusuke Tosauchi

26 February 2023 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
JKJae-Do Kang
Jae-Do Kang
KKKoichi Kajiwara
Koichi Kajiwara
YTYusuke Tosauchi
Yusuke Tosauchi
ESEiji Sato
Eiji Sato
TITakahito Inoue
Takahito Inoue
TMTomohisa Mukai
Tomohisa Mukai