Tatjana Isaković

Prof. Tatjana Isaković

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2020 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Open access
PDF file
GFGabriele Fiorentino
Gabriele Fiorentino
CCCihan Cengiz
Cihan Cengiz
FLFlavia De Luca
Flavia De Luca
George MylonakisGeorge Mylonakis
George Mylonakis
DKDimitris Karamitros
Dimitris Karamitros
Camillo NutiCamillo Nuti
Camillo Nuti
In recent years there has been renewed interest on integral abutment bridges (IABs), mainly due to their low construction and maintenance cost. Owing to the monolithic connection between deck and abutments, there is strong soil‐structure interaction between the bridge and the backfill under both thermal action and earthquake shaking. Although some of the regions where IABs are adopted qualify as highly seismic, there is limited knowledge as to their dynamic behaviour and vulnerability under strong ground shaking. To develop a better understanding on the seismic behaviour of IABs, an extensive experimental campaign involving over 75 shaking table tests and 4800 time histories of recorded data, was carried out at EQUALS Laboratory, University of Bristol, under the auspices of EU‐sponsored SERA project (Seismology and Earthquake Engineering Research Infrastructure Alliance for Europe). The tests were conducted on a 5 m long shear stack mounted on a 3 m × 3 m 6‐DOF earthquake simulator, focusing on interaction effects between a scaled bridge model, abutments, foundation piles and backfill soil. The study aims at (a) developing new scaling procedures for physical modelling of IABs, (b) investigating experimentally the potential benefits of adding compressible inclusions (CIs) between the abutment and the backfill and (c) exploring the influence of different types of connection between the abutment and the pile foundation. Results indicate that the CI reduces the accelerations on the bridge deck and the settlements in the backfill, while disconnecting piles from the cap decreases bending near the pile head.

12 July 2014
Verified
Book Chapter
Open access
PDF file
MFMatej Fischinger
Matej Fischinger
BZBlaž Zoubek
Blaž Zoubek
TITatjana Isaković
Tatjana Isaković
The most common structural system of the precast industrial buildings in Europe consists of an assemblage of cantilever columns tied together with beams. Typical beam-to-column connection in these structures is constructed with steel dowels. Although this system has been used for decades, its seismic response was poorly understood, which reflected in ambiguous code requirements and conservative approach. Therefore, along with innovative precast structural solutions (not discussed in this paper), this system was the main focus of the continuous European research in the past two decades. The key results of this vast research effort (including unprecedented cyclic, PSD and shake table experiments on large-scale structures) led by the associations of the precast producers in Europe and the Politecnico di Milano are presented and discussed in this paper. The details are provided for the work done at the University of Ljubljana. The results of these research projects led to some major modifications and improvements of the relevant chapter in Eurocode 8, when this was evolving from the initial informative annex to the final code provision. Refined FEM models for the complex behaviour of the dowel beam-to-column connections as well as macro models for the post-critical analysis of the complete structures were proposed. Single-storey and multi-storey structures were investigated and the design formulas to estimate high shear and storey-force amplification due to higher-modes effect in multi-storey structures were derived. The design guidelines for connections of precast structures under seismic actions were prepared. Systematic risk studies were done indicating that this structural system can be safe in seismic regions if all Eurocode 8 provisions as well as the recommendations based on the presented research are considered. These include the capacity design of the connections. Behaviour factor for such precast systems was studied and the values initially proposed in preEC8 were modified (increased). However, it was shown that drift limitations typically govern the design and that the nominal value of the behaviour factor is not so decisive. The key factors contributing to the good seismic behaviour of this system (assuming that the connections are properly designed) is the low value of the compressive axial force in the columns confined with adequate hoops and the overstrength caused by drift limitation requirements. Cladding-to-structure interaction has been one of the most poorly understood components of the system, which is now the topic of the on-going research.


1 May 2017 in Journal of Structural Engineering
Verified
Journal Article
Closed access
MFMatej Fischinger
Matej Fischinger
PKPeter Kante
Peter Kante
TITatjana Isaković
Tatjana Isaković
A shake-table test of a 1:3 scale model of a thin, lightly reinforced concrete (RC), 5-story coupled wall, representing a typical apartment building with a high wall-to-floor area ratio, was performed. The wall consisted of two T-shaped piers, faced to each other by the webs, which were connected at each story level by the coupling beam and slab. The wall was subjected to a series of uniaxial and biaxial seismic excitations. Two different structural details providing different degrees of confinement were used at the free edges without boundary columns. The lightly confined free edges of the flanges (using hairpin transverse reinforcement) behaved satisfactorily in the case of moderate seismic demand. Due to the beam–slab interaction and the slab, which was considerably ticker than in typical buildings, the coupling beams were much stronger than expected, causing brittle shear failure of the overloaded wall piers under bidirectional excitation. The analyzed wall developed substantial strength and low ductility. The main observations of the experiment were confirmed by the results of postexperimental analytical studies performed using a three-dimensional (3D) multiple vertical-line element model, which has been incorporated into a well-known open-code program system.

7 July 2023 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
AJAntonio Janevski
Antonio Janevski
JKJae-Do Kang
Jae-Do Kang
TITatjana Isaković
Tatjana Isaković
The capabilities of certain standard macro numerical models were evaluated by simulating a shaking table experiment that was performed on a full-scale ten-storey fixed-base building with a frame and dual structural system in two perpendicular directions (denoted as the frame and wall directions) at the largest shaking table in the E-Defense centre in Japan. The lumped plasticity model for columns and beams, the multiple-vertical-line-element model for walls and the scissors model for beam-column joints were evaluated. The results indicated that the experiment was simulated reasonably well. The most significant discrepancy was observed between the maximum drifts along the wall direction in the strongest cycle of the strongest test (calculated drift of 1.9% versus measured drift of 1.5%). In other cycles and tests, these differences were smaller. The calculated and measured maximum accelerations along the wall direction in the strongest test were 13.8 m/s 2 and 13.5 m/s 2 , respectively. The discrepancy between the analysis and experiment results was smaller along the frame direction. The maximum calculated and measured drifts were 2.9% and 3.1%, respectively. The maximum calculated and measured accelerations were 15.8 m/s 2 and 19.0 m/s 2 , respectively. In general, the standard input parameters were used in the evaluated models. However, some parameters required modifications, particularly when modelling weakly reinforced beam-column joints with substandard reinforcement that were considerably damaged. Their yielding rotation and near-collapse strength were, on average, reduced to 55% and 30% of the standard value, respectively. One of the most important parameters influencing the response was the effective width of the slabs, which was increased to the total span length for the highly loaded beams. The ratios of the strength, stiffness and amount of dissipated energy in the joints, beams and columns also significantly influenced the response. The adequate ratio of the dissipated energy was obtained by reducing the standard unloading stiffness in the beams and columns. The initial stiffness considerably influenced the response, particularly under weaker excitations. This stiffness was reduced threefold to account for various factors that typically reduce its value, which, among others, includes the influence of preceding tests on the same building with sliding foundations, as well as the assembly, transportation and handling of the specimen.

3 September 2019 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
MFM. Fischinger
M. Fischinger
TITatjana Isaković
Tatjana Isaković
KKK. Kolozvari
K. Kolozvari
JWJ. Wallace
J. Wallace