The aim of this work is to develop a new type of carbon-ceramic membranes for the removal of pharmaceutical substances from water. The membranes were prepared by the chemical modification method using an organosilicon precursor—octadecyltrichlorosilane (ODTS). Graphene oxide, multi-walled carbon nanotubes with carboxylic groups, and single-walled carbon nanotubes were used in the modification process. The filtration properties and adsorption properties of the developed membranes were tested. In order to characterize the membrane, the water permeability, the change of the permeate flux in time, and the adsorbed mass of the substance were determined. Additionally, the surface properties of the membranes were characterized by contact angle measurements and porosimetry. The antibiotic tetracycline was used in the adsorption tests. Based on the results, the improved adsorption properties of the modified membrane in relation to the unmodified membrane were noticed. Novel ceramic membranes modified with MWCNT are characterized by 45.4% removal of tetracycline and permeate flux of 520 L·h·m−2·bar−1. We demonstrated the ability of modified membranes to adsorb pharmaceuticals from water streams that are in contact with the membrane. Novel membranes retain their filtration properties. Therefore, such membranes can be used in an integrated filtration–adsorption process.
Background/Objectives: Antibiotic contamination in water sources is a growing global concern, contributing to environmental degradation and the proliferation of antimicrobial resistance. Traditional treatment methods, such as advanced oxidation or high-pressure membrane processes, are often energy-intensive and economically unsustainable for large-scale or decentralized applications. This study explores the potential of two cost-effective, commercially available metal–organic frameworks (MOFs), ZIF-8 and F300, to improve the performance of membrane-based filtration–adsorption systems for removing tetracycline and sulfadiazine from water. Methods: Batch adsorption experiments were performed to evaluate the uptake capacities, kinetics, and isotherms of both MOFs toward the selected antibiotics. The membranes were modified using a low-cost silane-assisted deposition of MOF particles and tested in a microfiltration system. Removal efficiencies and water permeability were assessed and kinetic and isotherm models were applied to understand the adsorption mechanisms. Results: ZIF-8 showed superior adsorption performance, with maximum capacities of 442.2 mg/g for tetracycline and 219.3 mg/g for sulfadiazine. F300 was effective only for tetracycline. Membranes modified with ZIF-8 improved pharmaceutical removal by 187% (tetracycline) and 224% (sulfadiazine) compared to unmodified membranes. Although permeability decreased due to increased hydrophobicity, the materials and processes remained economically favorable. Conclusions: This study demonstrates that MOF-modified ceramic membranes, particularly those incorporating ZIF-8, offer a low-cost, scalable, and energy-efficient alternative for pharmaceutical removal from water. The approach combines strong environmental impact with economic viability, making it attractive for broader implementation in water treatment systems.
The utilization of adsorptive nonwovens as a pretreatment unit may lead to novel, cost-efficient wastewater treatment technologies with remarkable properties for environmental protection, such as efficient adsorption of antibiotics. This paper uses graphene-modified nonwoven (GMN) to examine (i) how the adsorption of tetracycline (TCY)—especially since this antibiotic is frequently detected in the environment—takes place on an environmentally relevant concentration scale, and (ii) what factors influence the antibacterial and antifungal properties profile of this material class. This study demonstrates that combining graphene particles with commercial textile auxiliaries clearly enhances the antibacterial and antifungal properties of the modified nonwoven materials. The enzyme-linked immunosorbent assay (ELISA) was used to detect the TCY residues at ng/mL scale. The adsorption results follow Henry and Redlich–Peterson isotherms and emphasize the adsorption process at low concentration levels of TCY. Therefore, the appropriately designed GMNs have a great potential application for wastewater treatment in sewage plants. Statistical analysis (skewness and kurtosis) of nonwovens and modified nonwovens morphology allowed us to determine the parameters influencing the growth of fungi in such structures. GMN structures are capable of adsorbing antibiotics; a two-fold reduction of TCY was obtained in the studies.
Heterogeneous membranes, otherwise known as Mixed Matrix Membranes (MMMs), which are used in gas separation processes, are the subject of growing interest. This is due to their potential to improve the process properties of membranes compared to those of homogeneous membranes, i.e., those made of polymer only. Using such membranes in a process involves subjecting them to varying temperatures and pressures. This paper investigates the effects of temperature and feed pressure on the process properties of homogeneous and heterogeneous membranes. Membranes made of Pebax®2533 copolymer and containing additional fillers such as SiO2, ZIF−8, and POSS-Ph were investigated. Tests were performed over a temperature range of 25–55 °C and a pressure range of 2–8 bar for N2, CH4, and CO2 gases. It was found that temperature positively influences the increase in permeability, while pressure influences permeability depending on the gas used, which is related to the effect of pressure on the solubility of the gas in the membrane.
Heterogeneous membranes made of a polymer matrix and containing nano-metric fillers in their structure may present improved physicochemical and process properties compared to homogeneous membranes made only of polymer materials. Membranes made of a PEBAX®2533 block copolymer were tested with fillers such as ZIF-8, SiO2 and POSS-Ph being dosed to them. The material analysis and process tests indicate that these nanomaterials can be used as fillers for heterogeneous membranes. Chemometric analyses determined the influence of individual fillers on selected physicochemical properties of the materials which were used to produce the membranes. For specific concentrations of these fillers, improvement in the permeability and selectivity of the membranes, or at least in one of these parameters, was achieved. The greatest increase in permeability against the homogeneous membrane was obtained for membranes containing 10 wt% ZIF-8 (for CO2, an increase of 2.07 times; for CH4, 2.36 times; for N2, 3.08 times). In turn, the greatest increase in selectivity was obtained for the CO2/CH4 mixture for the membrane containing 5 wt% SiO2 (1.15 times), and for the CO2/N2 mixture for the membrane containing 2 wt% POSS-Ph (1.21 times).
In the aquatic environment, substances of pharmacological origin are common contaminants. The difficulty of removing them from water is a problem for the implementation of a circular economy policy. When recycling water, an effort should be made to remove, or at least, minimize the presence of these substances in the water. Porous membranes with a new functionality consisting in their adsorption capacity towards pharmaceutical substances have been developed. A Polyvinylidene Fluoride (PVDF) membrane with Calcium Carbonate (CaCO3) nanoparticles as an adsorbent was prepared. By implementing an integrated filtration-adsorption process using sulphadiazine, as a representative of pharmacological substances, 57 mg/m2 of adsorption capacity has been obtained, which is an improvement in adsorption properties of more than 50 times that of a commercial membrane. At the same time the membrane permeability is 0.29 m3/(h·m2·bar), which means that the membrane’s permeability was improved by 75%.