Treadmill exercise is commonly used as an alternative to over-ground walking or running. Increasing evidence indicated the kinetics of treadmill exercise is different from that of over-ground. Biomechanics of treadmill or over-ground exercises have been investigated in terms of energy consumption, ground reaction force, and surface EMG signals. These indexes cannot accurately characterize the musculoskeletal loading, which directly contributes to tissue injuries. This study aimed to quantify the differences of lower limb joint angles and muscle forces in treadmills and over-ground exercises. 10 healthy volunteers were required to walk at 100 and 120 steps/min and run at 140 and 160 steps/min on treadmill and ground. The joint flexion angles were obtained from the motion capture experiments and were used to calculate the muscle forces with an inverse dynamic method. Hip, knee, and ankle joint motions of treadmill and over-ground conditions were similar in walking, yet different in running. Compared with over-ground running, joint motion ranges in treadmill running were smaller. They were also less affected by stride frequency. Maximum Gastrocnemius force was greater in treadmill walking, yet maximum Rectus femoris and Vastus forces were smaller. Maximum Gastrocnemius and Soleus forces were greater in treadmill running. Treadmill exercise results in smoother joint kinematics. In terms of muscle force, treadmill exercise requires lower loading on knee extensor, yet higher loading on plantar flexor, especially on Gastrocnemius. The findings and the methodology can provide the basis for rehabilitation therapy customization and sophistic treadmill design.
26 May 2020 in International Journal for Numerical Methods in Biomedical Engineering
Objective: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures.Methods: Three groups of finite element models of the intact pelvis, including the main ligament and the proximal one‐third of both femurs, were developed to simulate vertical sacral fractures and treated with the three abovementioned internal fixation techniques. A 500 N vertical load, a 500 N vertical load plus a 10 Nm moment of forward sagittal direction, and 500 N vertical load plus a 10 Nm moment of right lateral direction were applied to the sacrum to simulate standing status, bending status, and flexion status, respectively. The maximum displacement value, the stress value, and the stress value of the fracture interface were compared among the three internal fixation techniques.Results: The results showed that all three internal fixation techniques effectively restored the biomechanical transmission of the injured pelvis. The stress on the implants in the TBP model was 167.47% and 53.41% higher than that in the ISS model and the MIAP model, respectively, and the stress shielding phenomenon of the TBP model was more obvious than in the other two models. Meanwhile, the stress between the fracture interfaces in the TBP fixation models was apparently higher than that in the other two models. However, the vertical displacement of the MIAP model was not significantly different from that in the ISS and TBP model; therefore, strong fixation could be obtained in all three models.Conclusion: Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels.
24 March 2019 in Journal of Healthcare Engineering
Patellofemoral pain syndrome has a high morbidity, and its pathology is closely associated with patellofemoral joint kinematics. A series of in vivo and in vitro studies have been conducted to explore patellofemoral kinematics, and the findings are relevant to the diagnosis, classification, and management of patellofemoral diseases and even the whole knee joint. However, no definite conclusion on normal patellofemoral kinematics has been established. In this study, the measurement methodologies of patellofemoral kinematics (including data collection methods, loading conditions, and coordinate system) as well as their advantages and limitations were reviewed. Motion characteristics of the patella were analyzed. During knee flexion, the patellar flexion angle lagged by 30–40% compared to the tibiofemoral joint flexion. The patella tilts, rotates, and shifts medially in the initial stage of knee flexion and subsequently tilts, rotates, and shifts laterally. The finite patellar helical axis fluctuates near the femoral transepicondylar axis or posterior condylar axis. Moreover, factors affecting kinematics, such as morphology of the trochlear groove, soft tissue balance, and tibiofemoral motion, were analyzed. At the initial period of flexion, soft tissues play a vital role in adjusting patellar tracking, and during further flexion, the status of the patella is determined by the morphology of the trochlear groove and patellar facet. Our findings could increase our understanding of patellofemoral kinematics and can help to guide the operation plan for patients with patellofemoral pain syndrome.
Purpose: Long-leg-radiography (LLR) is commonly used for the measurement of lower limb alignment. However, limb rotations during radiography may interfere with the alignment measurement. This study examines the effect of limb rotation on the accuracy of measurements based on the mechanical and anatomical axes of the femur and tibia, with variations in knee flexion and coronal deformity. Methods: Forty-five lower limbs of 30 patients were scanned with CT. Virtual LLRs simulating five rotational positions (neutral, ± 10 $$^{\circ }$$ , and ± 20 $$^{\circ }$$ internal rotation) were generated from the CT images. Changes in the hip–knee–ankle angle (HKA) and the femorotibial angle (FTA) were measured on each image with respect to neutral values. These changes were related to knee flexion and coronal deformity under both weight- and non-weight-bearing conditions. Results: The measurement errors of the HKA and FTA derived from limb rotation were up to 4.84 ± 0.66 $$^{\circ }$$ and 7.35 ± 0.88 $$^{\circ }$$ , respectively, and were correlated with knee flexion (p < 0.001) and severe coronal deformity (p < 0.001). Compared with the non-weight-bearing position, the coronal deformity measured in the weight-bearing condition was 2.62 $$^{\circ }$$ greater, the correlation coefficients between the coronal deformity and the deviation ranges of HKA and FTA were also greater. Conclusions: Flexion and severe coronal deformity have a significant influence on the measurement error of lower limb alignment. Errors can be amplified in the weight-bearing condition compared with the non-weight-bearing condition. When using HKA and FTA to represent the mechanical axis and the anatomical axis on LLR, limb rotation impacts the anatomic axis more than the mechanical axis in patients with severe deformities. Considering LLR as the gold standard image modality, attention should be paid to the measurement of knee alignment. Especially for the possible errors derived from weight-bearing long-leg radiographs of patients with severe knee deformities.
Long exposure to the microgravity will lead to muscle atrophy and bone loss. Treadmill exercise could mitigate the musculoskeletal decline. But muscle atrophy remains inevitable. The constraint loading applied on astronauts could affect the muscle force and its atrophy severity. However, the quantitative correlation between constraint loading mode and muscle forces remains unclear. This study aimed to characterize the influence of constraint loading mode on the lower limb muscle forces in weightless treadmill exercise. The muscle forces in the full gait cycle were calculated with the inverse dynamic model of human musculoskeletal system. The calculated muscle forces at gravity were validated with the EMG data. Muscle forces increased at weightlessness compared with those at the earth’s gravity. The increasing percentage from high to low is as follows: biceps femoris, gastrocnemius, soleus, vastus, and rectus femoris, which was in agreement with the muscle atrophy observed in astronauts. The constraint loading mode had an impact on the muscle forces in treadmill exercise and thus could be manipulated to enhance the effect of the muscle training in spaceflight. The findings could provide biomechanical basis for the optimization of treadmill constraint system and training program and improve the countermeasure efficiency in spaceflight.