Zecai Lin

Mr. Zecai Lin

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2024 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
AGAnzhu Gao
Anzhu Gao
ZLZecai Lin
Zecai Lin
CZCheng Zhou
Cheng Zhou
XAXiaojie Ai
Xiaojie Ai
BHBidan Huang
Bidan Huang
GYGuang-Zhong Yang
Guang-Zhong Yang
Cable-driven continuum robots are widely used for endoluminal intervention because of their dexterity and shape conforming steerability. However, body contact between the continuum robot and its surrounding anatomy is unavoidable, which imposes a potential safety risk, including vessel wall damage or even perforation. This article presents an approach for body contact estimation of continuum robots with tension-profile sensing of actuation fibers. First, tension-sensing optical fibers with multiple inscribed fiber Bragg grating sensors are used for both actuation and in-situ sensing of the continuum robot. Second, a beam theory-based mechanical model considering segmental differences, multiple fiber interactions, and external force interactions is established, followed by robust estimation of contact positions and forces. Finally, detailed simulations are conducted to validate the accuracy and effectiveness of the proposed method. Experiments on a notched continuum robot are carried out, and the results show that the proposed approach can effectively recover in-situ segmental actuation forces without the need of explicit modeling of the friction between the fibers and guiding channels. The method enables the estimation of the number of contact points, as well as contact positions and contact forces along the body of the continuum robot.

21 September 2021 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ZLZecai Lin
Zecai Lin
AGAnzhu Gao
Anzhu Gao
XAXiaojie Ai
Xiaojie Ai
HGHongyan Gao
Hongyan Gao
YFYILI FU
YILI FU
GYGuang-Zhong Yang
Guang-Zhong Yang
Current robotic endoluminal interventions require surgeons to hold a proximal joystick to control the distal flexible robot under 2-D X-ray guidance. However, the 2-D X-ray image is not intuitive, which not only increases the risk of surgical misoperation but also the workload of surgeons. Moreover, contact teleoperation exposes surgeons to the potentially infectious environment. To address it, this article proposes an augmented-reality-assisted touchless teleoperated robot for endoluminal intervention, called ARei. It aims to provide immersive experiences with augmented information. The robot integrates perceptual information obtained from an electromagnetic (EM) sensor, a shape sensor, and the virtual anatomy into a head-mounted display (HMD). The touchless teleoperation is used to control the robot, with the assistance of gesture recognition technology. Results show that the mean error of the calibration between the HMD and the EM tracking system is 4.67 mm, and the mean distance error between the points measured by the EM sensor and the points obtained by shape reconstruction with calibration is 5.19 mm (3.05%).

24 March 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
XAXiaojie Ai
Xiaojie Ai
AGAnzhu Gao
Anzhu Gao
ZLZecai Lin
Zecai Lin
CHChong He
Chong He
WCWeidong Chen
Weidong Chen
Cable-driven continuum manipulators have shown excellent benefits to work for endoluminal intervention. Demand of small diameter for confined anatomy limits the usage of multiple actuations, leading to limited DOFs and bending shapes. To address this problem, this letter proposes a multi-contact-aided continuum manipulator with anisotropic bending shapes. First, contact-aided compliant mechanisms (CCMs) are configured at different locations to introduce the specific constraints to enable the anisotropy. Then, the forward and inverse kinematic models considering contact blocks are built. The reachable workspace of the continuum manipulator is given, and simulation cases are studied to demonstrate the superiority of the proposed manipulator. Finally, a 3D-printed physical prototype is fabricated, and preliminary experiments are conducted to evaluate the model accuracy. Results show an average shape error of 1.98 mm (4.2%) and a maximum of 3.58 mm (7.6%). A robotic bronchoscopy platform integrated with the continuum manipulator is developed to conduct the airway phantom experiments. The shape deviation of the proposed manipulator from the centerline of the bronchus is 31.8% smaller than that of the constant curvature manipulator. The experiments validate the system-level feasibility and effectiveness of the developed continuum manipulator.

25 August 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
ZLZecai Lin
Zecai Lin
TZTianxue Zhang
Tianxue Zhang
ZSZhenglong Sun
Zhenglong Sun
HGHongyan Gao
Hongyan Gao
XAXiaojie Ai
Xiaojie Ai
AGAnzhu Gao
Anzhu Gao
Robotic telemedicine has a high potential to promote the development of future medicine. It enables the treatment of critical patients in geographically remote locations in time, and also particularly useful for avoiding infection risks during pandemics of infectious diseases. However, visual feedback from the patient’s side to the clinician’s side is often unintuitive due to a lack of depth information, occlusion, and viewing angles. This paper develops a robotic telepresence method based on augmented reality and human motion mapping for interventional medicine. An optical see-through head-mounted display (OST-HMD) is mounted at the distal end of a redundant manipulator, which can provide views from different directions, and the clinician can see through key anatomies and instruments located inside the patient body. The control of the manipulator is accomplished via human motion mapping, with both the end-effector and manifold of the human arm being mapped to the manipulator. A simple evaluation method is developed to assess the accuracy of head localization of the OST-HMD. Telepresence experiments are carried out to verify the effectiveness of the proposed method, with which the operator can see through a human airway phantom.

8 November 2023 in Advanced Intelligent Systems
Verified
Journal Article
Open access
ZLZecai Lin
Zecai Lin
ZXZheng Xu
Zheng Xu
HLHuanghua Liu
Huanghua Liu
XWXuyang Wang
Xuyang Wang
XAXiaojie Ai
Xiaojie Ai
AGAnzhu Gao
Anzhu Gao
Robotic telemedicine can provide timely treatment to critical patients in geographically remote locations. However, owing to the lack of depth information, occlusion of instrument, and view direction limitations, visual feedback from the patient to the clinician is typically unintuitive, which affects surgical safety. Herein, an omnidirectional augmented reality (AR)‐assisted robotic telepresence for interventional medicine is developed. A monocular camera is used as an AR device with a manipulator, where virtual key anatomies and instruments are superimposed on video images using multiobject hand–eye calibration, iterative closest point, and images superposition algorithms. The view direction of the camera can be changed via the manipulator, which allows the key anatomies and instruments to be viewed from different directions. Structure‐from‐motion and multi‐view stereo algorithms are used to reconstruct the scene on the patient's side, thus providing a virtual reality (VR) interactive interface for the manipulator's safe teleoperation. Two different phantom experiments are conducted to validate the effectiveness of the proposed method. Finally, an ex vivo experiment involving a porcine lumen is performed, in which the operator can view the interventional flexible robot. The proposed method integrates omnidirectional AR and VR with robotic telepresence, which can provide intuitive visual feedback to clinicians.

31 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CZcheng zhou
cheng zhou
ZLZecai Lin
Zecai Lin
SHShaoping Huang
Shaoping Huang
Bing LiBing Li
Bing Li
AGAnzhu Gao
Anzhu Gao
Advancements in robotic surgery help to improve the endoluminal diagnosis and treatment with minimally invasive or non-invasive intervention in a precise and safe manner. Miniaturized probe-based sensors can be used to obtain information about endoluminal anatomy, and they can be integrated with medical robots to augment the convenience of robotic operations. The tremendous benefit of having this physiological information during the intervention has led to the development of a variety of in vivo sensing technologies over the past decades. In this paper, we review the probe-based sensing techniques for the in vivo physical and biochemical sensing in China in recent years, especially on in vivo force sensing, temperature sensing, optical coherence tomography/photoacoustic/ultrasound imaging, chemical sensing, and biomarker sensing.