Bing Li

Dr. Bing Li

Institute for Materials Discovery, University College London, London WC1E 7JE, UK
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
YLYixuan Li
Yixuan Li
LLLiuxiong Luo
Liuxiong Luo
YKYingqi Kong
Yingqi Kong
YLYujia Li
Yujia Li
QWQuansheng Wang
Quansheng Wang
Bing LiBing Li
Bing Li
Molecularly imprinted polymers (MIPs) are the equivalent of natural antibodies and have been widely used as synthetic receptors for the detection of disease biomarkers. Benefiting from their excellent chemical and physical stability, low-cost, relative ease of production, reusability, and high selectivity, MIP-based electrochemical sensors have attracted great interest in disease diagnosis and demonstrated superiority over other biosensing techniques. Here we compare various types of MIP-based electrochemical sensors with different working principles. We then evaluate the state-of-the-art achievements of the MIP-based electrochemical sensors for the detection of different biomarkers, including nucleic acids, proteins, saccharides, lipids, and other small molecules. The limitations, which prevent its successful translation into practical clinical settings, are outlined together with the potential solutions. At the end, we share our vision of the evolution of MIP-based electrochemical sensors with an outlook on the future of this promising biosensing technology.

29 January 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
BRBruno Gil Rosa
Bruno Gil Rosa
OAOluwatomi E. Akingbade
Oluwatomi E. Akingbade
XGXiaotong Guo
Xiaotong Guo
LGLaura Gonzalez-Macia
Laura Gonzalez-Macia
MCMichael A. Crone
Michael A. Crone
Bing LiBing Li
Bing Li

13 May 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
RCRongwei Cui
Rongwei Cui
HTHuijing Tang
Huijing Tang
QHQing Huang
Qing Huang
TYTingsong Ye
Tingsong Ye
JCJiyang Chen
Jiyang Chen
DLDanyang Li
Danyang Li

19 January 2024 in Science Advances
Verified
Journal Article
Open access
MAMohamed E. M. K. Abdelaziz
Mohamed E. M. K. Abdelaziz
JZJinshi Zhao
Jinshi Zhao
BRBruno Gil Rosa
Bruno Gil Rosa
HLHyun-Taek Lee
Hyun-Taek Lee
DSDaniel Simon
Daniel Simon
Burak TemelkuranBurak Temelkuran
Burak Temelkuran
Precise manipulation of flexible surgical tools is crucial in minimally invasive surgical procedures, necessitating a miniature and flexible robotic probe that can precisely direct the surgical instruments. In this work, we developed a polymer-based robotic fiber with a thermal actuation mechanism by local heating along the sides of a single fiber. The fiber robot was fabricated by highly scalable fiber drawing technology using common low-cost materials. This low-profile (below 2 millimeters in diameter) robotic fiber exhibits remarkable motion precision (below 50 micrometers) and repeatability. We developed control algorithms coupling the robot with endoscopic instruments, demonstrating high-resolution in situ molecular and morphological tissue mapping. We assess its practicality and safety during in vivo laparoscopic surgery on a porcine model. High-precision motion of the fiber robot delivered endoscopically facilitates the effective use of cellular-level intraoperative tissue identification and ablation technologies, potentially enabling precise removal of cancer in challenging surgical sites.

18 August 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
YLYixuan Li
Yixuan Li
LLLiuxiong Luo
Liuxiong Luo
MNMengyan Nie
Mengyan Nie
ADAndrew Davenport
Andrew Davenport
YLYing Li
Ying Li
Kwang Leong ChoyKwang Leong Choy
Kwang Leong Choy
Accurate and reliable analysis of creatinine is clinically important for the early detection and monitoring of patients with kidney disease. We report a novel graphene nanoplatelet (GNP)/polydopamine (PDA)-molecularly imprinted polymer (MIP) biosensor for the ultra-trace detection of creatinine in a range of body fluids. Dopamine hydrochloride (DA) monomers were polymerized using a simple one-pot method to form a thin PDA-MIP layer on the surface of GNP with high density of creatinine recognition sites. This novel surface-MIP strategy resulted in a record low limit-of-detection (LOD) of 2 × 10-2 pg/ml with a wide dynamic detection range between 1 × 10-1-1 × 109 pg/ml. The practical application of this GNP/PDA-MIP biosensor has been tested by measuring creatinine in human serum, urine, and peritoneal dialysis (PD) fluids. The average recovery rate was 93.7-109.2% with relative standard deviation (RSD) below 4.1% compared to measurements made using standard clinical laboratory methods. Our GNP/PDA-MIP biosensor holds high promise for further development as a rapid, accurate, point-of-care diagnostic platform for detecting and monitoring patients with kidney disease.

15 December 2021 in ACS Sensors
Verified
Journal Article
Open access
LXLizhou Xu
Lizhou Xu
SRSami Ramadan
Sami Ramadan
OAOluwatomi E. Akingbade
Oluwatomi E. Akingbade
YZYuanzhou Zhang
Yuanzhou Zhang
SASarah Alodan
Sarah Alodan
Bing LiBing Li
Bing Li
Glial fibrillary acidic protein (GFAP) is a discriminative blood biomarker for many neurological diseases, such as traumatic brain injury. Detection of GFAP in buffer solutions using biosensors has been demonstrated, but accurate quantification of GFAP in patient samples has not been reported, yet in urgent need. Herein, we demonstrate a robust on-chip graphene field-effect transistor (GFET) biosensing method for sensitive and ultrafast detection of GFAP in patient plasma. Patients with moderate–severe traumatic brain injuries, defined by the Mayo classification, are recruited to provide plasma samples. The binding of target GFAP with the specific antibodies that are conjugated on a monolayer GFET device triggers the shift of its Dirac point, and this signal change is correlated with the GFAP concentration in the patient plasma. The limit of detection (LOD) values of 20 fg/mL (400 aM) in buffer solution and 231 fg/mL (4 fM) in patient plasma have been achieved using this approach. In parallel, for the first time, we compare our results to the state-of-the-art single-molecule array (Simoa) technology and the classic enzyme-linked immunosorbent assay (ELISA) for reference. The GFET biosensor shows competitive LOD to Simoa (1.18 pg/mL) and faster sample-to-result time (<15 min), and also it is cheaper and more user-friendly. In comparison to ELISA, GFET offers advantages of total detection time, detection sensitivity, and simplicity. This GFET biosensing platform holds high promise for the point-of-care diagnosis and monitoring of traumatic brain injury in GP surgeries and patient homes.