Himanshu Sharma

Dr. Himanshu Sharma


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
SSShilpa Sambhi
Shilpa Sambhi
HSHimanshu Sharma
Himanshu Sharma
VBVikas Singh Bhadoria
Vikas Singh Bhadoria
PKPankaj Kumar
Pankaj Kumar
RCRavi Chaurasia
Ravi Chaurasia
CPChristos Pavlatos
Christos Pavlatos
This paper mainly dealt with the technical and economic feasibility of an off-grid hybrid power generation system for a remote rural Turtuk village of Ladakh, located in the northern part of India. The study showed that the proposed configured renewable integrated hybrid system, using Hybrid Optimization of Multiple Energy Resources (HOMER) software, efficiently met the energy demand, exhibiting optimum performance with low investment. The proposed PV(115 kW)/Wind(1 kW)/Battery(164 strings of 6 V each)/DG(50 kW) hybrid system was a highly commendable, feasible solution preferred from a total of 133,156 available solutions resulting from HOMER simulations. The net present cost and energy cost of the proposed configuration were $278,176 and $0.29/kWh, respectively. The proposed hybrid configuration fulfilled local load, with 95.97% reduced dominant harmful carbon dioxide emission, as compared to the sole us of a diesel generator power supply system. The technical performance of the hybrid system was ensured, with advantages including the highest renewable penetration and least unmet load. Furthermore, the analysis exclusively evaluated the impact of the system’s economic parameters (namely, its expected inflation rate, nominal discount rate, and project lifetime) on the net present cost and cost of energy of the system using a noble single fix duo vary approach.

24 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
SSShilpa Sambhi
Shilpa Sambhi
HSHimanshu Sharma
Himanshu Sharma
PKPankaj Kumar
Pankaj Kumar
Georgios FotisGeorgios Fotis
Georgios Fotis
Vasiliki VitaVasiliki Vita
Vasiliki Vita
Lambros EkonomouLambros Ekonomou
Lambros Ekonomou
The limited availability of fossil fuels such as coal and increasing air pollution levels due to the burning of coal have pushed the trend of generating electricity from fossil fuels to generating it from locally available renewable resources. It is expected that the cost of electricity will decrease when locally available renewable resources are used. In this paper, it was proposed to commission a solar PV system in a part of an academic building of SRM IST University. The present study is an effort in-line with many initiatives taken up by the Indian Government. The performance index of solar PV system was analyzed. Supporting data were obtained from the NASA PDAV tool and then techno-economical analysis was carried out on HOMER. The average performance ratio and capacity factor of the solar PV system were obtained as 64.49% and 14.90%, respectively. For the optimal configuration, the net present cost and the levelized cost of electricity are $639,981 and $0.34 per kWh, respectively. As per the estimation, there will be no air pollution due to the proposed configuration, whereas if only a diesel generator is commissioned, then 200,417 kg of carbon dioxide will be emitted annually.

16 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
SSShilpa Sambhi
Shilpa Sambhi
HSHimanshu Sharma
Himanshu Sharma
VBVikas Singh Bhadoria
Vikas Singh Bhadoria
PKPankaj Kumar
Pankaj Kumar
RCRavi Chaurasia
Ravi Chaurasia
Vasiliki VitaVasiliki Vita
Vasiliki Vita
This paper presents atechnical and economic analysis of the proposed solar PV/diesel generator smart hybrid power plant for a part of SRM IST, Delhi-NCR campus. The analysis was performed using five battery storage technologies: lead-acid, lithium-ion, vanadium flow, zinc bromide and nickel-iron. The analysis also used the HOMER Pro software. The analysis was conducted to assess performance parameters such as initial cost, simple payback period, return on investment, energy produced, renewable penetration and emission of air pollutants. The optimal solution was obtained as SPP(200 kW)/DG(82 kW)/ZB(2000 kWh), with cycle charging dispatch strategy. The initial cost of this configuration is estimated to be USD163,445, and the operating cost is USD534 per year. The net present cost is estimated to be USD170,348, and the estimated cost of energy with this configuration has been obtained as USD0.090 per kWh. It is estimated that with this optimal solution, the diesel generator may consume only 110 L/year of diesel, which is the minimum of all configurations. Sensitivity analysis was performed between the size of the solar PV array and the size of the battery, along with variations in the battery’s nominal capacity and renewable fraction.

9 April 2023 in Designs
Verified
Journal Article
Open access
PDF file
SSShilpa Sambhi
Shilpa Sambhi
HSHimanshu Sharma
Himanshu Sharma
VBVikas Singh Bhadoria
Vikas Singh Bhadoria
PKPankaj Kumar
Pankaj Kumar
Georgios FotisGeorgios Fotis
Georgios Fotis
Lambros EkonomouLambros Ekonomou
Lambros Ekonomou
This work intends to perform technical and 2E (economic & environmental) analysis for the proposed hybrid energy generating system for a part load at SRM IST at the Delhi-NCR campus, India. The investigation has been done for electricity generation and hydrogen production through renewable energy sources, mainly solar energy. It is in line with the Indian Government’s initiatives. The proposed hybrid system has to meet the electric load demand of 400 kWh/day with a peak load of 74.27 kW and hydrogen load demand of 10 kg/day with a peak demand of 1.86 kg/h. The analysis has been performed for both on-grid and off-grid conditions. As a result, optimum results have been obtained off-grid condition, with $0.408 per kWh cost of energy, $16.6 per kg cost of hydrogen, low O&M cost ($21,955 per year), a high renewable fraction (99.8%), and low greenhouse emissions (247 kg/year). In addition, sensitivity analysis has been performed between—(1) the solar PV array size & the number of battery strings, with NPC, renewable fraction & CO2 emissions as sensitivity variables, and (2) reformer capacity & hydrogen tank capacity, with NPC as sensitivity variable.

30 June 2023
Verified
Book Chapter
Closed access
PDF file
SSShilpa Sambhi
Shilpa Sambhi
HSHimanshu Sharma
Himanshu Sharma
VBVikas Bhadoria
Vikas Bhadoria
PKPankaj Kumar
Pankaj Kumar