Aim: This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). Methods: 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. Results: The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (− 16.5 dB C/MHL) and in noise (− 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. Conclusions: The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient’s anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.
Single molecule localization microscopy (SMLM) is one of the key techniques that break the classical resolution limit in optical imaging. It is based on taking multiple recordings of a sample, each showing only a sparse arrangement of spatially well separated fluorescent molecules which can be localized at nanometer precision. While localizing along the lateral directions is usually straightforward, estimating axial positions at a comparable precision is known to be much harder, which is due to the relatively large depth of focus provided by the microscope optics. Whenever a molecule is sufficiently close to the coverslip, it becomes feasible to draw additional information from near field coupling effects: super-critical angle fluorescence (SAF) appears and can be exploited to boost the axial localization precision. Here we propose defocused imaging as a SMLM strategy that is capable of leveraging the information contained in SAF. We show that, regarding axial localization precision, our approach is superior to established SAF-based approaches. At the same time it is simple and can be conducted on any research-grade microscope where controlled defocusing on the order of a few hundred nanometers is possible.
Estimating the post-mortem interval (PMI) of human skeletal remains is a critical issue of forensic analysis, with important limitations such as sample preparation and practicability. In this work, NIR spectroscopy (NIRONE® Sensor X; Spectral Engines, 61449, Germany) was applied to estimate the PMI of 104 human bone samples between 1 day and 2000 years. Reflectance data were repeatedly collected from eight independent spectrometers between 1950 and 1550 nm with a spectral resolution of 14 nm and a step size of 2 nm, each from the external and internal bone. An Artificial Neural Network was used to analyze the 66,560 distinct diagnostic spectra, and clearly distinguished between forensic and archaeological bone material: the classification accuracies for PMIs of 0–2 weeks, 2 weeks–6 months, 6 months–1 year, 1 year–10 years, and >100 years were 0.90, 0.94, 0.94, 0.93, and 1.00, respectively. PMI of archaeological bones could be determined with an accuracy of 100%, demonstrating the adequate predictive performance of the model. Applying a handheld NIR spectrometer to estimate the PMI of human skeletal remains is rapid and extends the repertoire of forensic analyses as a distinct, novel approach.
It is challenging to estimate the post-mortem interval (PMI) of skeletal remains within a forensic context. As a result of their interactions with the environment, bones undergo several chemical and physical changes after death. So far, multiple methods have been used to follow up on post-mortem changes. There is, however, no definitive way to estimate the PMI of skeletal remains. This research aimed to propose a methodology capable of estimating the PMI using micro-computed tomography measurements of 104 human skeletal remains with PMIs between one day and 2000 years. The present study indicates that micro-computed tomography could be considered an objective and precise method of PMI evaluation in forensic medicine. The measured parameters show a significant difference regarding the PMI for Cort Porosity p < 0.001, BV/TV p > 0.001, Mean1 p > 0.001 and Mean2 p > 0.005. Using a machine learning approach, the neural network showed an accuracy of 99% for distinguishing between samples with a PMI of less than 100 years and archaeological samples.
Bone analyses using mid-infrared spectroscopy are gaining popularity, especially with handheld spectrometers that enable on-site testing as long as the data quality meets standards. In order to diagnose Staphylococcus epidermidis in human bone grafts, this study was carried out to compare the effectiveness of the Agilent 4300 Handheld Fourier-transform infrared with the Perkin Elmer Spectrum 100 attenuated-total-reflectance infrared spectroscopy benchtop instrument. The study analyzed 40 non-infected and 10 infected human bone samples with Staphylococcus epidermidis, collecting reflectance data between 650 cm−1 and 4000 cm−1, with a spectral resolution of 2 cm−1 (Agilent 4300 Handheld) and 0.5 cm−1 (Perkin Elmer Spectrum 100). The acquired spectral information was used for spectral and unsupervised classification, such as a principal component analysis. Both methods yielded significant results when using the recommended settings and data analysis strategies, detecting a loss in bone quality due to the infection. MIR spectroscopy provides a valuable diagnostic tool when there is a tissue shortage and time is of the essence. However, it is essential to conduct further research with larger sample sizes to verify its pros and cons thoroughly.
30 July 2024 in European Archives of Oto-Rhino-Laryngology
Purpose: To evaluate the diagnostic performance (DP) of the high-resolution contrast computed tomography (HR-contrast-CT) based Neck-Persistency-Net in distinguishing vital from non-vital persistent cervical lymph nodes (pcLNs) in patients with advanced head and neck squamous cell carcinoma (HNSCC) following primary concurrent chemoradiotherapy (CRT) with [18F]-fluorodeoxyglucose positron emission tomography and high-resolution contrast-enhanced computed tomography ([18F]FDG-PET-CT). Furthermore, the Neck-Persistency-Net’s potential to justify omitting post-CRT neck dissection (ND) without risking treatment delays or preventing unnecessary surgery was explored. Methods: All HNSCC patients undergoing primary CRT followed by post-CRT-ND for pcLNs recorded in the institutional HNSCC registry were analyzed. The Neck-Persistency-Net DP was explored for three scenarios: balanced performance (BalPerf), optimized sensitivity (OptSens), and optimized specificity (OptSpec). Histopathology of post-CRT-ND served as a reference. Results: Among 68 included patients, 11 were female and 32 had vital pcLNs. The Neck-Persistency-Net demonstrated good DP with an area under the curve of 0.82. For BalPerf, both sensitivity and specificity were 78%; for OptSens (90%), specificity was 62%; for OptSpec (95%), sensitivity was 54%. Limiting post-CRT-ND to negative results would have delayed treatment in 27%, 40%, and 7% for BalPerf, OptSens and OptSpec, respectively, versus 23% for [18F]FDG-PET-CT. Conversely, restricting post-CRT-ND to positive results would have prevented unnecessary post-CRT-ND in 78%, 60%, and 95% for BalPerf, OptSens and OptSpec, respectively, versus 55% for [18F]FDG-PET-CT. Conclusion: The DP of the Neck-Persistency-Net was comparable to [18F]-FDG-PET-CT. Depending on the chosen decision boundary, the potential to justify the omission of post-CRT-ND without risking treatment delays in false negative findings or reliably prevent unnecessary surgery in false positive findings outperforms the [18F]-FDG-PET-CT.