Jacqueline Chua

Dr. Jacqueline Chua

Singapore Eye Research Institute, Singapore, Central Singapore, Singapore
+1
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Progress in Retinal and Eye Research
Verified
Journal Article
Open access
MAMarcus Ang
Marcus Ang
MBMani Baskaran
Mani Baskaran
René M. WerkmeisterRené M. Werkmeister
René M. Werkmeister
JCJacqueline Chua
Jacqueline Chua
DSDoreen Schmidl
Doreen Schmidl
LSLeopold Schmetterer
Leopold Schmetterer
Optical coherence tomography (OCT) provides non-contact, rapid in vivo imaging of ocular structures, and has become a key part of evaluating the anterior segment of the eye. Over the years, improvements to technology have increased the speed of capture and resolution of images, leading to the increasing impact of anterior segment OCT imaging on clinical practice. In this review, we summarize the historical development of anterior segment OCT, and provide an update on the research and clinical applications of imaging the ocular surface, cornea, anterior chamber structures, aqueous outflow system, and most recently anterior segment vessels. We also describe advancements in anterior segment OCT technology that have improved understanding with greater detail, such as tear film in dry eye disease evaluation, intra-operative real-time imaging for anterior segment surgery, and aqueous outflow with angle assessment for glaucoma. Improvements to image processing and software have also improved the ease and utility of interpreting anterior segment OCT images in everyday clinical practice. Future developments include refinement of assessing vascular networks for the anterior segment, in vivo ultra-high resolution anterior segment optical coherence tomography with histology-like detail, en-face image with 3-dimensional reconstruction as well as functional extensions of the technique.

2 September 2009 in Acta Ophthalmologica
Verified
Journal Article
Open access
PDF file
TSTetsuya Sugiyama
Tetsuya Sugiyama
MAMakoto Araie
Makoto Araie
CRCharles E. Riva
Charles E. Riva
LSLeopold Schmetterer
Leopold Schmetterer
SOSelim Orgul
Selim Orgul
Acta Ophthalmol. 2010: 88: 723–729: Laser speckle flowgraphy (LSFG) allows for the quantitative estimation of blood flow in the optic nerve head, choroid, retina and iris in vivo. It was developed to facilitate the non‐contact analysis of ocular blood flow in living eyes, utilizing the laser speckle phenomenon. The technique uses a fundus camera, a diode laser, an image sensor, an infrared charge‐coupled device (CCD) camera and a high‐resolution digital CCD camera. Normalized blur (NB), an approximate reciprocal of speckle contrast, represents an index of blood velocity, and shows a good correlation with tissue blood flow rates determined with the microsphere method in the retina, choroid or iris, as well as blood flow rates determined with the hydrogen gas clearance method in the optic nerve head. The square blur ratio (SBR), another index for quantitative estimation of blood velocity, is proportional to the square of the NB. The SBR is theoretically a more exact measurement which is proportional to velocity, whereas the NB is an approximation. Normalized blur was calculated in earlier versions of LSFG because of technical limitations; the SBR is used in current versions of the LSFG instrument. As these values are in arbitrary units, they should not be used to make comparisons between different eyes or different sites in an eye. Clinical protocols, calibration, evaluation procedures and possible limitations of the LSFG technique are described and the results of ocular blood flow studies using LSFG are briefly summarized. The LSFG method is suitable for monitoring the time–course of change in the tissue circulation at the same site in the same eye at various intervals, ranging from seconds to months. Unresolved issues concern the effect of pupil size on measurement results, the effects of various stimulations, and how to measure choroidal and retinal blood flow velocity separately without using the blue‐component of argon laser.

1 July 2014 in Progress in Retinal and Eye Research
Verified
Journal Article
Open access
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
RWRené M. Werkmeister
René M. Werkmeister
CBCedric Blatter
Cedric Blatter
LSLeopold Schmetterer
Leopold Schmetterer
Optical Coherence Tomography (OCT) has revolutionized ophthalmology. Since its introduction in the early 1990s it has continuously improved in terms of speed, resolution and sensitivity. The technique has also seen a variety of extensions aiming to assess functional aspects of the tissue in addition to morphology. One of these approaches is Doppler OCT (DOCT), which aims to visualize and quantify blood flow. Such extensions were already implemented in time domain systems, but have gained importance with the introduction of Fourier domain OCT. Nowadays phase-sensitive detection techniques are most widely used to extract blood velocity and blood flow from tissues. A common problem with the technique is that the Doppler angle is not known and several approaches have been realized to obtain absolute velocity and flow data from the retina. Additional studies are required to elucidate which of these techniques is most promising. In the recent years, however, several groups have shown that data can be obtained with high validity and reproducibility. In addition, several groups have published values for total retinal blood flow. Another promising application relates to non-invasive angiography. As compared to standard techniques such as fluorescein and indocyanine-green angiography the technique offers two major advantages: no dye is required and depth resolution is required is provided. As such Doppler OCT has the potential to improve our abilities to diagnose and monitor ocular vascular diseases.

1 February 2013 in Current Opinion in Pharmacology
Verified
Journal Article
Open access
APAlina Popa-Cherecheanu
Alina Popa-Cherecheanu
GGG Garhofer
G Garhofer
DSDoreen Schmidl
Doreen Schmidl
RWR Werkmeister
R Werkmeister
LSLeopold Schmetterer
Leopold Schmetterer
Glaucoma is a progressive optic neuropathy of unknown origin. It has been hypothesized that a vascular component is involved in glaucoma pathophysiology. This hypothesis has gained support from studies showing that reduced ocular perfusion pressure is a risk factor for the disease. The exact nature of the involvement is, however, still a matter of debate. Based on recent evidence we propose a model including primary and secondary insults in glaucoma. The primary insult appears to happen at the optic nerve head. Increased intraocular pressure and ischemia at the post-laminar optic nerve head affects retinal ganglion cell axons. Modulating factors are the biomechanical properties of the tissues and cerebrospinal fluid pressure. After this primary insult retinal ganglion cells function at a reduced energy level and are sensitive to secondary insults. These secondary insults may happen if ocular perfusion pressure falls below the lower limit of autoregulation or if neurovascular coupling fails. Evidence for both faulty autoregulation and reduced hyperemic response to neuronal stimulation has been provided in glaucoma patients. The mechanisms appear to involve vascular endothelial dysfunction and impaired astrocyte-vessel signaling. A more detailed understanding of these pathways is required to direct neuroprotective strategies via the neurovascular pathway.

1 August 2011 in Experimental Eye Research
Verified
Journal Article
Closed access
DSDoreen Schmidl
Doreen Schmidl
GGGerhard Garhofer
Gerhard Garhofer
LSLeopold Schmetterer
Leopold Schmetterer

18 November 2013 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
VCVital P. Costa
Vital P. Costa
AHAlon Harris
Alon Harris
DADouglas Anderson
Douglas Anderson
RSRichard Stodtmeister
Richard Stodtmeister
FCFernanda Cremasco
Fernanda Cremasco
LSLeopold Schmetterer
Leopold Schmetterer