Ryo Miyake

Ryo Miyake


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
PGPANPAN GAO
PANPAN GAO
TTTkasama T
Tkasama T
JSJungchan Shin
Jungchan Shin
YHYixuan Huang
Yixuan Huang
RMRyo Miyake
Ryo Miyake
Laser-induced graphene (LIG) has been applied in many different sensing devices, from mechanical sensors to biochemical sensors. In particular, LIG fabricated on paper (PaperLIG) shows great promise for preparing cheap, flexible, and disposable biosensors. Distinct from the fabrication of LIG on polyimide, a two-step process is used for the fabrication of PaperLIG. In this study, firstly, a highly conductive PaperLIG is fabricated. Further characterization of PaperLIG confirmed that it was suitable for developing biosensors. Subsequently, the PaperLIG was used to construct a biosensor by immobilizing glucose oxidase, aminoferrocene, and Nafion on the surface. The developed glucose biosensor could be operated at a low applied potential (−90 mV) for amperometric measurements. The as-prepared biosensor demonstrated a limit of detection of (50–75 µM) and a linear range from 100 µM to 3 mM. The influence of the concentration of the Nafion casting solution on the performance of the developed biosensor was also investigated. Potential interfering species in saliva did not have a noticeable effect on the detection of glucose. Based on the experimental results, the simple-to-prepare PaperLIG-based saliva glucose biosensor shows great promise for application in future diabetes management.

23 August 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
TSTOMOMI SATO
TOMOMI SATO
KMKoji Masuda
Koji Masuda
CSChikako Sano
Chikako Sano
KMKeiji Matsumoto
Keiji Matsumoto
Hidetoshi NumataHidetoshi Numata
Hidetoshi Numata
RMRyo Miyake
Ryo Miyake
Microreactor technologies have emerged as versatile platforms with the potential to revolutionize chemistry and materials research, offering sustainable solutions to global challenges in environmental and health domains. This survey paper provides an in-depth review of recent advancements in microreactor technologies, focusing on their role in facilitating accelerated discoveries in chemistry and materials. Specifically, we examine the convergence of microfluidics with machine intelligence and automation, enabling the exploitation of the cyber-physical environment as a highly integrated experimentation platform for rapid scientific discovery and process development. We investigate the applicability and limitations of microreactor-enabled discovery accelerators in various chemistry and materials contexts. Despite their tremendous potential, the integration of machine intelligence and automation into microreactor-based experiments presents challenges in establishing fully integrated, automated, and intelligent systems. These challenges can hinder the broader adoption of microreactor technologies within the research community. To address this, we review emerging technologies that can help lower barriers and facilitate the implementation of microreactor-enabled discovery accelerators. Lastly, we provide our perspective on future research directions for democratizing microreactor technologies, with the aim of accelerating scientific discoveries and promoting widespread adoption of these transformative platforms.

22 June 2017 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
TSTomomi Sato
Tomomi Sato
RMRyo Miyake
Ryo Miyake
We have developed an integrated flow cytometry chip, which comprises a pre-treatment part and a sheath flow-forming part with a twisted microchannel structure, for continuous monitoring of bacteria in drinking water.

6 September 2023 in iScience
Verified
Journal Article
Open access
YWYecan Wang
Yecan Wang
HMHiroshi Murakami
Hiroshi Murakami
TKToshihiro Kasama
Toshihiro Kasama
SMShigenobu Mitsuzawa
Shigenobu Mitsuzawa
SSSatoru Shinkawa
Satoru Shinkawa
MTMadoka Takai
Madoka Takai
Conventional competitive enzyme-linked immunosorbent assay (ELISA) to measure the cortisol level in body fluid consumes a large amount of time, owing to complicated operations involved and requirement for precise control of reagent addition. We developed an automatic microfluidic system to detect salivary cortisol rapidly, and an electrospun polystyrene (PS) microfiber-based reactor providing considerable binding sites for antibody immobilization, thus resolving the time limitations of competitive ELISA. Cortisol sample, horseradish peroxidase (HRP)-conjugated cortisol, and 3,3′,5,5′-tetramethylbenzidine (TMB) substrate were delivered to the PS reactor from containers in sequence by pumps automatically. The color variation due to oxidized TMB complex reflects the cortisol concentration level measured using an RGB phototransistor. In addition, the entire procedure from sample introduction to obtaining the photocurrent took only 15 min. This system can be implemented to quantify cortisol from 0.37 ng/mL to 30 ng/mL, and the limit of detection was estimated at 0.37 ng/mL.

27 April 2023 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
HTHidekatsu Tazawa
Hidekatsu Tazawa
TSTomomi Sato
Tomomi Sato
YSYu Sakuta
Yu Sakuta
RMRyo Miyake
Ryo Miyake
The demand for multi-point water quality monitoring is increasing to solve the global problem of safe drinking water supply and environmental water contamination by industries. Therefore, compact devices are needed for on-site water quality analysis. On-site devices require low cost and high durability because they are placed outdoors, exposing them to strong ultraviolet rays and a wide range of temperatures. Our previous study reported on a compact and low-cost water quality meter that uses microfluidic devices with resin to monitor chemicals. In this study, we extended the fabrication range of the glass molding method to fabricate a glass microfluidic device with a 300 µm deep channel on a 50 mm in diameter substrate for constructing a low-cost and high-durability device. Finally, we developed a low-cost, highly robust glass device with a diamond-like carbon-coated channel surface to measure residual chlorine. The experimental results indicated that this device can endure outdoor conditions and be attached to small internet of things devices for analyzing chemical substances, such as residual chlorine. Graphical Abstract

15 February 2022 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
Jungchan ShinJungchan Shin
Jungchan Shin
TKToshihiro Kasama
Toshihiro Kasama
RMRyo Miyake
Ryo Miyake