22 June 2017 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
TSTomomi Sato
Tomomi Sato
RMRyo Miyake
Ryo Miyake
We have developed an integrated flow cytometry chip, which comprises a pre-treatment part and a sheath flow-forming part with a twisted microchannel structure, for continuous monitoring of bacteria in drinking water.

21 July 2017
Verified
Conference Paper
Open access
TSTomomi Sato
Tomomi Sato
RMRyo Miyake
Ryo Miyake
We have been developing a compact and low-cost flow cytometry unit (Figure 1) suitable for a variety of water monitoring needs. We have been developing an integrated flow cytometry chip, which comprises a pre-treatment part and a sheath flow-forming part with a twisted microchannel structure, biological cells were successfully detected at the proposed chip [1][2]. We constructed a compact and low-cost monitoring unit with a light emitting diode (LED) based optical setup. In this presentation, we introduce the compact and low-cost flow cytometry unit and demonstrate the ability to measure the particles. Figure 2 shows a schematic of flow cytometry chip and an image of the twisted flow cytometry chip. Figure 3 shows a photograph of the fabricated chip. The flow cytometry chip made of Polydimethylsiloxane (PDMS) and the sheath flow-forming part is twisted by 180 degrees (°). The length of the sheath flow channel was designed to be twisted by 90° at second junction and the sheath flow was formed. Figure 4 shows a schematic of the optical setup. A laser and a PMT of the conventional optical setup were changed to the LED and the optical sensor in the new setup. We assessed the detecting ability of the compact and low-cost flow cytometry unit using standard fluorescent particles. Figure 5 shows a photograph of the compact and low-cost flow cytometry unit. The unit is a 60 mm cubic. Water including the fluorescent particles was used as the sample fluid. The flow rates of the sheath fluid and the sample fluid were set to 0.10 µl/sec and 0.017 µl/sec, respectively. The mean flow velocity at observation point is 1.3 mm/sec. Figure 6 shows the signals from particles. The signals of particles were successfully detected using the LED based optical setup. In summary, we constructed the compact and low-cost flow cytometry unit for monitoring particles in water and the signal of particles were successfully detected.

5 March 2026 in The Analyst
Verified
Journal Article
Open access
PDF file
MKMasayuki Kawakami
Masayuki Kawakami
TTTkasama T
Tkasama T
TSTomomi Sato
Tomomi Sato
HTHidekatsu Tazawa
Hidekatsu Tazawa
MTMadoka Takai
Madoka Takai
RMRyo Miyake
Ryo Miyake
A compact wireless residual chlorine monitor was developed using a glass mixing and reaction device and an absorbance flowcell. The monitor tracked chlorine concentration changes during the chlorine injection process in a circulating cooling system.