Lalli Dharmarajan

Dr. Lalli Dharmarajan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
FNFerenc Nagy
Ferenc Nagy
DGDorottya Gheorghita
Dorottya Gheorghita
LDLalli Dharmarajan
Lalli Dharmarajan
GBGábor Braunitzer
Gábor Braunitzer
Alexandru AchimAlexandru Achim
Alexandru Achim
Márk Adam AntalMárk Adam Antal
Márk Adam Antal
Introduction: There is a well-documented association between coronary artery disease (CHD) and periodontal disease (PD) mediated by common inflammatory pathways. This association, however, has not been investigated extensively in the special context of in-stent restenosis. This study aimed to investigate the periodontal status of patients undergoing percutaneous coronary intervention (PCI) for restenotic lesions. Methods and Results: We enrolled 90 patients undergoing percutaneous coronary intervention and 90 age- and gender-matched healthy controls in the present study. All subjects received a full-mouth examination by a periodontist. Plaque index, periodontal status, and tooth loss were determined. The periodontal state was significantly worse (p < 0.0001) in the PCI group, and each periodontal stage increased the odds of belonging to the PCI group. This effect of PD was independent of diabetes mellitus, another strong risk factor for CAD. The PCI group was further divided into two subgroups: PCI for restenotic lesions (n = 39) and PCI for de novo lesions (n = 51). Baseline clinical and procedural characteristics were comparable between the two PCI subgroups. A significant (p < 0.001) association was found between the PCI subgroup and the severity of periodontal disease, with the incidence of severe PD reaching 64.1%. Conclusions: Patients undergoing PCI for in-stent restenosis exhibit more severe forms of periodontal disease not only as compared to healthy controls but also as compared to patients stented for de novo lesions. The potential causality between PD and restenosis must be studied in larger prospective studies.

15 October 2022 in Medicina
Verified
Journal Article
Open access
PDF file
LDLalli Dharmarajan
Lalli Dharmarajan
PPPSG Prakash
PSG Prakash
DADevapriya Appukuttan
Devapriya Appukuttan
JASMINE CRENAJASMINE CRENA
JASMINE CRENA
SSSangeetha Subramanian
Sangeetha Subramanian
Shankargouda PatilShankargouda Patil
Shankargouda Patil
Background and Objectives: The study aimed to compare the mean crestal bone level (CBL) and peri-implant soft tissue parameters in laser micro-grooved (LMG) platform switched implants and abutments (I&A) post 1 year of functional loading among non-diabetic and type II diabetic individuals. Materials and methods: Patients with an edentulous site having minimum bone height and width of ≥13 mm and ≥6 mm, respectively, were divided into two groups: (i) Non-diabetic-8 (control) and (ii) diabetic-8 (test). LMG Implants were placed and loaded immediately with a provisional prosthesis. Mean crestal bone level (MCBL) was evaluated radiographically at baseline and at 1 year. Peri-implant attachment level (PIAL) and relative position of the gingival margin (R-PGM) were recorded. Implant stability quotient (ISQ) level and implant survival rate (ISR) were evaluated at 1 year. Results: Early MCBL within the groups 1 year postloading was similar both mesially and distally (control—0.00 to 0.16 mm and 0.00 to 0.17 mm, respectively; test—0.00 to 0.21 mm and 0.00 to 0.22 mm, respectively) with statistical significance (p ≤ 0.003, p ≤ 0.001 and p ≤ 0.001, p ≤ 0.001, respectively). However, intergroup comparison showed no significant difference statistically in the MCBL in 1 year post functional loading. The peri-implant soft tissue parameters showed no significant difference between the groups. ISQ level between both groups did not reveal any significant changes (p ≤ 0.92), and ISR was 100%. Conclusions: LMG Implants resulted in minimal and comparable early crestal bone loss and soft tissue changes post 1 year of functional loading in moderately controlled diabetic and non-diabetic individuals, suggesting that this could be a reliable system for use in systemically compromised individuals.