Karsten Hansen

Dr. Karsten Hansen

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
MPMatteo Porro
Matteo Porro
LALadislav Andricek
Ladislav Andricek
SAStefan Aschauer
Stefan Aschauer
ACAndrea Castoldi
Andrea Castoldi
MDMattia Donato
Mattia Donato
CWCornelia B. Wunderer
Cornelia B. Wunderer
The first DSSC 1-Mpixel camera became available at the European XFEL (EuXFEL) in the Hamburg area in February 2019. It was successfully tested, installed, and commissioned at the Spectroscopy and Coherent Scattering Instrument. DSSC is a high-speed, large-area, 2-D imaging detector system optimized for photon science applications in the energy range between 0.25 and 6 keV. The camera is based on direct conversion Si sensors and is composed of 1024 ×1024 pixels of hexagonal shape with a side length of 136 μm. The 256 application-specific integrated circuits (ASICs) provide full parallel readout, comprising analog filtering, digitization, and in-pixel data storage. In order to cope with the demanding X-ray pulse time structure of the EuXFEL, the DSSC provides a peak frame rate of 4.5 MHz. The first Mpixel camera is equipped with miniaturized silicon drift detector (MiniSDD) pixel arrays. The intrinsic response of the pixels and the linear readout limit the dynamic range but allow one to achieve noise values of about 60 electrons r.m.s. at the highest frame rate. The challenge of providing high-dynamic range (~10 4 photons/pixel/pulse) and single-photon detection simultaneously requires a nonlinear system front end, which will be obtained with the DEPFET active pixel technology foreseen for the advanced version of the camera. This technology will provide lower noise and a nonlinear response at the sensor level. This article describes the architecture of the whole detector system together with the main experimental results achieved up to now.

20 February 2023 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
LGLoïc Le Guyader
Loïc Le Guyader
AEAndrea Eschenlohr
Andrea Eschenlohr
MBMartin Beye
Martin Beye
WSWilliam Schlotter
William Schlotter
FDFlorian Döring
Florian Döring
ASAndreas Scherz
Andreas Scherz
Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.

29 September 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
NHNanna Zhou Hagström
Nanna Zhou Hagström
MSMichael Schneider
Michael Schneider
NKNico Kerber
Nico Kerber
AYAlexander Yaroslavtsev
Alexander Yaroslavtsev
EPErick Burgos Parra
Erick Burgos Parra
EJEmmanuelle Jal
Emmanuelle Jal
The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, results from the first megahertz-repetition-rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL are presented. The experimental capabilities that the SCS instrument offers, resulting from the operation at megahertz repetition rates and the availability of the novel DSSC 2D imaging detector, are illustrated. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range.

21 June 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
HWHåkan Wennlöf
Håkan Wennlöf
ACAnkur Chauhan
Ankur Chauhan
MVManuel Del Rio Viera
Manuel Del Rio Viera
DEDoris Eckstein
Doris Eckstein
FFFinn Feindt
Finn Feindt
GVGianpiero Vignola
Gianpiero Vignola

1 October 2013 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
KHKarsten Hansen
Karsten Hansen
CRChristian Reckleben
Christian Reckleben
PKPradeep Kalavakuru
Pradeep Kalavakuru
JSJanusz Szymanski
Janusz Szymanski
IDInge Diehl
Inge Diehl
A pixel-level 8-bit 5-MS/s Wilkinson-type analog-to-digital converter was designed and fabricated in the IBM 8M1P 130-nm CMOS technology. The pixel blocks are implemented with a core area of 130 μm by 140 μm, consuming about 560 μW at 1.2 V. Taking the measured dynamic range of 0.86 V into account, a signal-to-noise ratio above 65 dB was achieved for small signal amplitudes. The maximum differential and integral nonlinearity remains well below 0.4 LSB and 0.5 LSB, respectively. The conversion time is 160 ns, and the energy per conversion step 470 fJ. The digitizer permits the trimming of gain and offset.

1 September 2017 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
KHKarsten Hansen
Karsten Hansen
SKS. Kousar
S. Kousar
DPD. Pitzl
D. Pitzl
SAS. Arab
S. Arab