5 October 2020 in Nature Materials
29 April 2021 in IEEE Transactions on Nuclear Science
The first DSSC 1-Mpixel camera became available at the European XFEL (EuXFEL) in the Hamburg area in February 2019. It was successfully tested, installed, and commissioned at the Spectroscopy and Coherent Scattering Instrument. DSSC is a high-speed, large-area, 2-D imaging detector system optimized for photon science applications in the energy range between 0.25 and 6 keV. The camera is based on direct conversion Si sensors and is composed of 1024 ×1024 pixels of hexagonal shape with a side length of 136 μm. The 256 application-specific integrated circuits (ASICs) provide full parallel readout, comprising analog filtering, digitization, and in-pixel data storage. In order to cope with the demanding X-ray pulse time structure of the EuXFEL, the DSSC provides a peak frame rate of 4.5 MHz. The first Mpixel camera is equipped with miniaturized silicon drift detector (MiniSDD) pixel arrays. The intrinsic response of the pixels and the linear readout limit the dynamic range but allow one to achieve noise values of about 60 electrons r.m.s. at the highest frame rate. The challenge of providing high-dynamic range (~10 4 photons/pixel/pulse) and single-photon detection simultaneously requires a nonlinear system front end, which will be obtained with the DEPFET active pixel technology foreseen for the advanced version of the camera. This technology will provide lower noise and a nonlinear response at the sensor level. This article describes the architecture of the whole detector system together with the main experimental results achieved up to now.
18 October 2004 in IEEE Transactions on Nuclear Science
Time-invariant shaping amplifiers, like semi-Gaussian shapers, are widely used to provide the best noise performances in detection systems based on high-resolution X-ray or /spl gamma/-ray detectors. A new "RC" cell which can be used for the realization of integrated semi-Gaussian shapers either with real or with complex poles has been designed. The proposed solution, which allows to implement RC time constants in the order of few /spl mu/s, is based on the well known technique of demagnification of the current flowing in a resistor R by means of the use of current mirrors. The architecture here adopted allows a more flexible coupling of the cell with the pole-zero network following the preamplifier and a precise and stable implementation of the desired time constant, for given values of R and C. Moreover, it can be biased with low currents, in order to minimize the shaper contribution to the overall parallel electronic noise, without affecting the precision of the time constant. A shaping amplifier based on this cell has been designed in the 0.35 /spl mu/m AMS technology. The main features of the circuit, the simulations of noise performances, and the preliminary experimental results of the first prototype are presented in this paper.
1 May 2010 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
14 January 2013 in IEEE Transactions on Nuclear Science
VERITAS (VErsatile Readout based on Integrated Trapezoidal Analog Shapers) is the first 128-channel ASIC developed to read out both the pnCCDs and the DEPFET arrays produced at the MPI-Halbleiterlabor in Munich. These detectors are used in a large variety of scientific applications, ranging from high-speed optical astronomy and X-ray astronomy to the new X-ray Free Electron Laser sources. The main concept of VERITAS is to provide a flexible readout chip able to cope not only with different kinds of detectors, but also with a large set of operating conditions that may require very different noise thresholds and input dynamic ranges. These can vary by more than two orders of magnitude. Every analog channel of VERITAS provides a trapezoidal weighting function. This filtering strategy had never been applied to the pnCCD before. The very first measurements obtained coupling VERITAS with a 128 × 256 pnCCD are shown. With a readout time of 4 μs/line a noise of 3.9 electrons has been measured in the highest gain mode. The resolution obtained on the Mn-Kα peak of a 55Fe source is 136 eV for single events. A noise of 30 electrons has been achieved in the lowest gain mode at a speed of 6.4 μs/line. In this low gain setting an input charge up to 2 5 × 105 electrons can be processed. These striking results fulfill the requirements of the main foreseen applications of large-size pnCCDs. In order to further improve the performance and the flexibility of the ASIC, a second version based on a fully differential architecture has been designed. The new topology allows one also to switch with the same ASIC between the source follower and drain current readout of the DEPFET sensors and to reach a processing time of about 2-3 μs/line with an electronics noise ≤10 el. For this reason the second version of VERITAS is very attractive for the proposed ESA X-ray astronomy mission ATHENA.
20 February 2023 in Journal of Synchrotron Radiation
Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.