Shanghai Jiang

Dr. Shanghai Jiang

Chongqing University of Technology, Chongqing, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
BLBinbin Luo
Binbin Luo
YWYajie Wang
Yajie Wang
HLHuafeng Lu
Huafeng Lu
SWShengxi Wu
Shengxi Wu
YLYouming Lu
Youming Lu
MZMingfu Zhao
Mingfu Zhao
Programmed death ligand-1 (PD-L1) plays an important role in tumor evasion from the host immune system. The level of soluble PD-L1 (sPD-L1) in serum is closely related to tumor aggressiveness and outcomes. This study aimed to propose a localized surface Plasmon resonance (LSPR) biosensor based on excessively tilted fiber grating (ExTFG) coated with large-sized (∼160 nm) gold nanoshells for label-free and specific detection of sPD-L1. The experimental results showed that the limit of detection (LOD) of the immunosensor for sPD-L1 in buffer solutions was ∼1 pg/mL due to the enhanced LSPR effect resulting from the interaction between sPD-L1 molecules and anti-sPD-L1 monoclonal antibodies. The detection of sPD-L1 in complex serum media, such as fetal bovine serum, confirmed that the label-free immunosensor was extremely specific to sPD-L1 and could identify it at a concentration as low as 5 pg/mL. Therefore, it can be potentially applied in clinic for the fast and early diagnosis of cancer.

12 December 2022 in Applied Optics
Verified
Journal Article
Closed access
HCHuiji Chen
Huiji Chen
BLBinbin Luo
Binbin Luo
DWDecao Wu
Decao Wu
XYXiangwen Yang
Xiangwen Yang
SSShenghui Shi
Shenghui Shi
MZMingfu Zhao
Mingfu Zhao
This study proposes a refractive index (RI) sensor using a cascaded tapered thin-core microfiber (TTCMF) based on the Vernier effect. The thin-core fiber was made into a TTCMF by arc discharging and flame heating and then sandwiched between two single-mode fibers (SMFs). The two structures with the same SMF–TTCMF–SMF but slightly different free spectral ranges (FSRs) were cascaded to generate the Vernier effect. The FSR varied with the taper parameters of TTCMF. The RI sensitivities of a single TTCMF sensor, series SMF–TTCMF–SMF sensor, and parallel SMF–TTCMF–SMF sensor were compared and analyzed. Using the Vernier effect in the RI measurement range from 1.3313 to 1.3392, a very high RI sensitivity of − 15 , 053.411 n m / R I U was obtained using the series SMF–TTCMF–SMF structure, and − 16 , 723.243 n m / R I U using the parallel structure, which were basically consistent with the simulation results. Compared with the RI sensitivity of the single TTCMF sensor, the RI sensitivities of series and parallel sensors were increased by 4.65 times and 5.16 times, respectively. In addition, in the temperature range from 35°C to 65°C, temperature sensitivities of − 0.196 n m / ∘ C and − 0.0489 n m / ∘ C were obtained using series and parallel structures, respectively; the corresponding temperature cross errors were 1.302 × 10 − 5 R I U / ∘ C and 2.92 × 10 − 6 R I U / ∘ C , respectively. Based on the advantages of high RI sensitivity, simple structure, low-temperature cross sensitivity, and convenient fabrication, the proposed sensors have great potential in biosensing fields.

11 September 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
YXYao Xu
Yao Xu
ZCZhongmin Chen
Zhongmin Chen
XWXiaohui Wang
Xiaohui Wang
SJShanghai Jiang
Shanghai Jiang
WFWang Fuping
Wang Fuping
HLHong Lu
Hong Lu

2 December 2022 in Photonics
Verified
Journal Article
Open access
PDF file
SYShuang Yang
Shuang Yang
SJShanghai Jiang
Shanghai Jiang
SSshi shenghui
shi shenghui
XHXinyu Hu
Xinyu Hu
MZMingfu Zhao
Mingfu Zhao
X-ray fluorescence computed tomography (XFCT) has attracted wide attention due to its ability to simultaneously and nondestructively obtain structural and elemental distribution information within samples. In this paper, we presented an image system based on the pinhole collimator for the polychromatic L-shell XFCT to reduce time consumption and improve the detection limit. First, the imaging system model was expressed by formulas and discretized. Then, two phantoms (A and B) were scanned by numerical simulation and Monte Carlo simulation. Both phantoms with the same diameter (10 mm) and height (10 mm) were cylinders filled with PMMA, and embedded with GNP-loaded cylinders. The phantom A was inserted by six 1.5 mm-diameter cylinders with different Au concentrations ranging from 0.2% to 1.2%. The phantom B was inserted by eight cylinders with the same Au concentration (1%), but a radius ranging from 0.1 mm to 0.8 mm. Finally, the reconstruction of the XFCT images was performed using the method with and without absorption correction, respectively. The feasibility of XFCT system presented in this paper was demonstrated by the numerical simulation and the Monte Carlo simulation. The results show that absorption attenuation can be corrected by the presented method, and the contrast to noise ratio (CNR) is proportional to Au concentration but almost remains unchanged with the radius of GNP-loaded cylinders, which may provide the necessary justification for further optimization of the imaging system.

24 November 2025 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
ZWZiqiang Wu
Ziqiang Wu
DWDecao Wu
Decao Wu
BLBinbin Luo
Binbin Luo
SJShanghai Jiang
Shanghai Jiang
XZXue Zou
Xue Zou
YCYanru Chen
Yanru Chen

7 January 2025 in IEEE Access
Verified
Journal Article
Open access
SJShanghai Jiang
Shanghai Jiang
LCLe Chen
Le Chen
JZJie Zhong
Jie Zhong
LALi Ai
Li Ai
HYHua Yang
Hua Yang
HLHong Lu
Hong Lu
In this paper, an Ordered Subsets Expectation Maximization (OSEM) reconstruction algorithm based on Total Variation (TV) constraint was applied for sparse reconstruction of X-ray fluorescence CT. First, the Geant4 Monte Carlo code was used to simulate the imaging process of fan beam X-ray fluorescence CT imaging system based on parallel hole collimator. Then, the reconstructed image quality of the proposed algorithm with varying numbers of projections was evaluated using RMSE and CNR. Finally, the relationship between the number of subsets of the algorithm and the quality of the reconstructed image and the reconstruction time was explored. The results demonstrated that, compared with the conventional OSEM algorithm, the proposed OSEM algorithm based on Total Variation constraint has higher quality of reconstructed images at different projection numbers, and the reconstruction time of the algorithm decreases with the increase of subset, which achieves the purpose of improving the quality of the reconstructed image and reducing the reconstruction time when sparse reconstruction.