Toxoplasma gondii (T. gondii) is a zoonotic parasite that is widely distributed and seriously endangers public health and human health. Therefore, accurate and effective detection of T. gondii is crucial. This study proposes a microfluidic biosensor using a thin-core microfiber (TCMF) coated with molybdenum disulfide (MoS2) for immune detection of T. gondii. The single-mode fiber was fused with the thin-core fiber, and the TCMF was obtained by arc discharging and flame heating. In order to avoid interference and protect the sensing structure, the TCMF was encapsulated in the microfluidic chip. MoS2 and T. gondii antigen were modified on the surface of TCMF for the immune detection of T. gondii. Experimental results showed that the detection range of the proposed biosensor for T. gondii monoclonal antibody solutions was 1 pg/mL to 10 ng/mL with sensitivity of 3.358 nm/log(mg/mL); the detection of limit was calculated to be 87 fg/mL through the Langmuir model; the dissociation constant and the affinity constant were calculated to be about 5.79 × 10−13 M and 1.727 × 1014 M−1, respectively. The specificity and clinical characteristics of the biosensor was explored. The rabies virus, pseudorabies virus, and T. gondii serum were used to confirm the excellent specificity and clinical characteristics of the biosensor, indicating that the proposed biosensor has great application potential in the biomedical field.
X-ray fluorescence computed tomography (XFCT) has attracted wide attention due to its ability to simultaneously and nondestructively obtain structural and elemental distribution information within samples. In this paper, we presented an image system based on the pinhole collimator for the polychromatic L-shell XFCT to reduce time consumption and improve the detection limit. First, the imaging system model was expressed by formulas and discretized. Then, two phantoms (A and B) were scanned by numerical simulation and Monte Carlo simulation. Both phantoms with the same diameter (10 mm) and height (10 mm) were cylinders filled with PMMA, and embedded with GNP-loaded cylinders. The phantom A was inserted by six 1.5 mm-diameter cylinders with different Au concentrations ranging from 0.2% to 1.2%. The phantom B was inserted by eight cylinders with the same Au concentration (1%), but a radius ranging from 0.1 mm to 0.8 mm. Finally, the reconstruction of the XFCT images was performed using the method with and without absorption correction, respectively. The feasibility of XFCT system presented in this paper was demonstrated by the numerical simulation and the Monte Carlo simulation. The results show that absorption attenuation can be corrected by the presented method, and the contrast to noise ratio (CNR) is proportional to Au concentration but almost remains unchanged with the radius of GNP-loaded cylinders, which may provide the necessary justification for further optimization of the imaging system.