Sarah Vogel

Ms. Sarah Vogel


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2023 in Cancers
Verified
Journal Article
Open access
PDF file
FMFlorian Mentzel
Florian Mentzel
JPJason Paino
Jason Paino
MBMicah Barnes
Micah Barnes
MCMatthew Cameron
Matthew Cameron
SCStéphanie Corde
Stéphanie Corde
SGSusanna Guatelli
Susanna Guatelli
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumor diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Monte Carlo (MC) simulations are one of the most used methods at the Imaging and Medical Beamline, Australian Synchrotron to calculate the dose in MRT preclinical studies. The steep dose gradients associated with the 50μm-wide coplanar beamlets present a significant challenge for precise MC simulation of the dose deposition of an MRT irradiation treatment field in a short time frame. The long computation times inhibit the ability to perform dose optimization in treatment planning or apply online image-adaptive radiotherapy techniques to MRT. Much research has been conducted on fast dose estimation methods for clinically available treatments. However, such methods, including GPU Monte Carlo implementations and machine learning (ML) models, are unavailable for novel and emerging cancer radiotherapy options such as MRT. In this work, the successful application of a fast and accurate ML dose prediction model for a preclinical MRT rodent study is presented for the first time. The ML model predicts the peak doses in the path of the microbeams and the valley doses between them, delivered to the tumor target in rat patients. A CT imaging dataset is used to generate digital phantoms for each patient. Augmented variations of the digital phantoms are used to simulate with Geant4 the energy depositions of an MRT beam inside the phantoms with 15% (high-noise) and 2% (low-noise) statistical uncertainty. The high-noise MC simulation data are used to train the ML model to predict the energy depositions in the digital phantoms. The low-noise MC simulations data are used to test the predictive power of the ML model. The predictions of the ML model show an agreement within 3% with low-noise MC simulations for at least 77.6% of all predicted voxels (at least 95.9% of voxels containing tumor) in the case of the valley dose prediction and for at least 93.9% of all predicted voxels (100.0% of voxels containing tumor) in the case of the peak dose prediction. The successful use of high-noise MC simulations for the training, which are much faster to produce, accelerates the production of the training data of the ML model and encourages transfer of the ML model to different treatment modalities for other future applications in novel radiation cancer therapies.

30 January 2023 in Journal of Nanotheranostics
Verified
Journal Article
Open access
PDF file
SVSarah Vogel
Sarah Vogel
AOAlice O’keefe
Alice O’keefe
LSLéa Seban
Léa Seban
MVMichael Valceski
Michael Valceski
EEElette Engels
Elette Engels
MTMoeava Tehei
Moeava Tehei
Gold nanoparticles are a promising candidate for developing new strategies of therapy against cancer. Due to their high atomic number and relative biocompatibility, they are commonly investigated as radiosensitizers to locally increase the dose of radiotherapy. In order to optimize this radiosensitizing effect, it is necessary to control the positioning of the nanoparticles in the cells. The purpose of this study is to investigate, by means of fluorescent gold nanoparticles in suspension, the dose enhancement on highly radio-resistant cancer cells. These nanoparticles were successfully produced using modern click-chemistry methods, first by attaching a chelating agent Diethylenetriamine pentaacetate benzylamine to L-cysteine, bonding the resulting ligand to a gold core, grafting propargylamine and then utilizing copper-catalyzed azide-alkyne cycloaddition (CuAAC) to fuse AlexaFluor 647 to the ligands. The results of this study prove the success of the reactions to produce a minimally cytotoxic and highly stable nanoparticle suspension that increases the radiosensitivity of gliosarcoma 9L tumor cells, with a 35% increase in cell death using 5 Gy kilovoltage radiation. Their fluorescent functionalization allowed for their simple localization within living cells and detection in vivo post-mortem.

20 June 2023 in Radiation
Verified
Journal Article
Open access
PDF file
JPJason Paino
Jason Paino
MCMatthew Cameron
Matthew Cameron
MLMatthew Large
Matthew Large
MBMicah Barnes
Micah Barnes
EEElette Engels
Elette Engels
MLMichael Lerch
Michael Lerch
This work describes the creation and experimental validation of DoseMRT, a new software package, and its associated workflow for dose calculations in synchrotron-generated broad beam and microbeam radiation treatment fields. The DoseMRT software package allows users to import CT DICOM datasets into Geant4 for Monte Carlo dose calculations. It also provides basic treatment planning capabilities, simplifying the complexity of performing Geant4 simulations and making our Monte Carlo dose calculation algorithm accessible to a broader range of users. To demonstrate the new package, dose calculations are validated against experimental measurements performed in homogeneous water tank phantoms and the anatomically complex Alderson Radiotherapy Phantom for both broad-beam and microbeam configurations. Additionally, DoseMRT is successfully utilised as the primary method for patient-specific treatment prescription in an in vivo experiment involving tumour-bearing rats at the Imaging and Medical Beamline of the Australian Synchrotron.

14 October 2023 in Radiation
Verified
Journal Article
Open access
PDF file
EEElette Engels
Elette Engels
JPJason Paino
Jason Paino
SVSarah Vogel
Sarah Vogel
MVMichael Valceski
Michael Valceski
AKAbass Khochaiche
Abass Khochaiche
MTMoeava Tehei
Moeava Tehei
Synchrotron Microbeam Radiation Therapy (MRT) is an innovative technique that spatially segments the synchrotron radiation field for cancer treatment. A microbeam peak dose is often hundreds of times the dose in the valley (the sub-millimeter region between the peaks of the microbeams). Peak and valley doses vary with increasing depth in tissue which effects tumor dose coverage. It remains to be seen whether the peak or valley is the primary factor in MRT cancer control. This study investigates how unilateral MRT doses can be modulated using a bolus, and identifies the valley dose as a primary factor in MRT cancer control. Fischer rats bearing 9 L gliosarcoma tumors were irradiated with MRT at the Imaging and Medical Beam Line of the Australian Synchrotron. MRT valley doses of 8–15 Gy (250–1040 Gy peak doses) were used to treat tumors with and without a 5 mm dose-modulating bolus. Long-term survival depended on the valley dose primarily (92% correlation), and the use of the bolus reduced the variance in animal survival and improved to the mean survival of rats treated with MRT by 47% and 18% using 15 Gy and 8 Gy valley doses, respectively.

19 December 2024 in Cancers
Verified
Journal Article
Open access
PDF file
MVMichael Valceski
Michael Valceski
EEElette Engels
Elette Engels
SVSarah Vogel
Sarah Vogel
JPJason Paino
Jason Paino
DPDylan Potter
Dylan Potter
MTMoeava Tehei
Moeava Tehei
Background/Objectives: Brain cancer is notoriously resistant to traditional treatments, including radiotherapy. Microbeam radiation therapy (MRT), arrays of ultra-fast synchrotron X-ray beams tens of micrometres wide (called peaks) and spaced hundreds of micrometres apart (valleys), is an effective alternative to conventional treatments. MRT’s advantage is that normal tissues can be spared from harm whilst maintaining tumour control. Combining MRT with targeted radiosensitisers, such as nanoparticles, chemotherapeutic drugs, and halogenated pyrimidine drugs, can further improve radiotherapy by enhancing radiation damage. However, the underlying mechanisms of MRT are still being understood, which is essential to ensuring the reliable and successful use of MRT. Methods: An in vitro study was performed using γH2AX imaging, and quantification was performed via confocal microscopy and a clonogenic cell survival assay. Results: We show that methotrexate chemotherapeutics and iododeoxyuridine enhance MRT cell-killing and thulium oxide nanoparticles (TmNPs) broaden MRT peaks, and using γH2AX immunofluorescent confocal microscopy to quantify DNA damage, we further our knowledge of MRT mechanisms. γH2AX images verify the biological responses of cells aligning with the physical collimation of MRT, and we can accurately measure MRT microbeam characteristics bio-dosimetrically. The peak-to-valley dose ratio (PVDR), the ratio of the peak dose to the valley dose that characterises an MRT field, was accurately measured biologically using γH2AX imaging, despite studies previously finding this challenging. Conclusions: The measurement of biological PVDR has been performed for the first time with high-Z radiosensitisers, including nanoparticles, and several novel radiosensitiser-enhanced MRT mechanisms were discovered. Our results deepen our understanding of MRT with radiosensitisers, and can contribute to its accurate and future successful use in treating cancer.

Verified
Journal Article
Open access
PDF file
MVMichael Valceski
Michael Valceski
AOAnson Tsan Yin O
Anson Tsan Yin O
AOAlice O'Keefe
Alice O'Keefe
SVSarah Vogel
Sarah Vogel
EEElette Engels
Elette Engels
MTMoeava Tehei
Moeava Tehei
High-Z nanoparticles (NPs) have the potential to revolutionize cancer radiotherapy by radiosensitising tumours. This is particularly important for radioresistant cancers such as glioblastoma. A newer NP candidate in this area is thulium oxide nanoparticles (TmNPs). However, prior to clinical assessment, ideal NP characteristics, including biocompatibility, biosafety, and preferential uptake in cancer, should be assessed. This in vitro study compares the effects of TmNP treatment, without radiation, on 9L gliosarcoma (9LGS), a well-established glioblastoma cell model, with exposure to Madin Darby Canine Kidney (MDCK) cells, a widely used non-cancerous cell model. The findings demonstrated selective uptake of TmNPs in 9LGS over MDCK following treatment. A biological assessment of toxicity confirmed minimal long-term effects on MDCK, whilst TmNPs were observed to induce some notable cell death in 9LGS. Excessive TmNP uptake in 9LGS over time was observed to induce cell vacuolisation, which resulted in cell death via necrosis. It was concluded that this was the explanation for the underlying mechanisms of TmNP toxicity in cancer cells. This study was therefore able to demonstrate not only that TmNPs are a biocompatible, cancer-selective candidate for radiosensitiser usage, but further provided a theory to explain its mechanisms of cancer cell toxicity.