Julia Kristin Hufenbach

Prof. Dr. Julia Kristin Hufenbach

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
BPBirgit Paul
Birgit Paul
ALAnja Lode
Anja Lode
APAnna-Maria Placht
Anna-Maria Placht
AVAndrea Voß
Andrea Voß
SPStefan Pilz
Stefan Pilz
JHJulia Kristin Hufenbach
Julia Kristin Hufenbach
Additive manufacturing is a promising technology for the fabrication of customized implants with complex geometry. The objective of this study was to investigate the initial cell–material interaction of degradable Fe-30Mn-1C-0.02S stent structures in comparison to conventional 316L as a reference, both processed by laser powder bed fusion. FeMn-based alloys have comparable mechanical properties with clinically applied AISI 316L for a corrosion-resistant stent material. Different corrosion stages of the as-built Fe-30Mn-1C-0.02S stent surfaces were simulated by pre-conditioning in DMEM under cell culture conditions for 2 h, 7 days, and 28 days. Human umbilical vein endothelial cells (HUVECs) were directly seeded onto the pre-conditioned samples, and cell viability, adherence, and morphology were analyzed. These studies were accompanied by measurements of iron and manganese ion release and Auger electron spectroscopy to evaluate the influence of corrosion products and degradation on the cells. In the initial phase (2 h of pre-conditioning), HUVECs were able to attach but the cell number decreased over the cultivation period of 14 days and the CD31 staining pattern of intercellular contacts was disordered. At later time points of corrosion (7 and 28 days of pre-conditioning), CD31 staining was distinctly located at the intercellular contacts, and the cell density increased after seeding and was stable for up to 14 days. Formation of a complex degradation layer, which had a composition and thickness dependent on the pre-conditioning time, led to a reduced ion release and finally showed a positive effect on cell survival. Concluding, our data suggest the suitability of Fe-30Mn-1C-0.02S for in vivo applications.

10 June 2021 in Metals
Verified
Journal Article
Open access
PDF file
MOMartin Otto
Martin Otto
SPStefan Pilz
Stefan Pilz
GAGebert Annett
Gebert Annett
UKUta Kühn
Uta Kühn
JHJulia Kristin Hufenbach
Julia Kristin Hufenbach
In the last decade, additive manufacturing technologies like laser powder bed fusion (LPBF) have emerged strongly. However, the process characteristics involving layer-wise build-up of the part and the occurring high, directional thermal gradient result in significant changes of the microstructure and the related properties compared to traditionally fabricated materials. This study presents the influence of the build direction (BD) on the microstructure and resulting properties of a novel austenitic Fe-30Mn-1C-0.02S alloy processed via LPBF. The fabricated samples display a {011} texture in BD which was detected by electron backscatter diffraction. Furthermore, isolated binding defects could be observed between the layers. Quasi-static tensile and compression tests displayed that the yield, ultimate tensile as well as the compressive yield strength are significantly higher for samples which were built with their longitudinal axis perpendicular to BD compared to their parallel counterparts. This was predominantly ascribed to the less severe effects of the sharp-edged binding defects loaded perpendicular to BD. Additionally, a change of the Young’s modulus in dependence of BD could be demonstrated, which is explained by the respective texture. Potentiodynamic polarization tests conducted in a simulated body fluid revealed only slight differences of the corrosion properties in dependence of the build design.

1 April 2020 in Advanced Engineering Materials
Verified
Journal Article
Open access
PDF file
JHJulia Kristin Hufenbach
Julia Kristin Hufenbach
JSJan Sander
Jan Sander
FKFabian Kochta
Fabian Kochta
SPStefan Pilz
Stefan Pilz
AVAndrea Voss
Andrea Voss
AGAnnett Gebert
Annett Gebert
Selective laser melting (SLM) of biodegradable metallic materials offers a great potential for manufacturing customized implants. Herein, SLM processing of a novel Fe–30Mn–1C–0.02S twinning‐induced plasticity (TWIP) alloy and the resulting structural, mechanical, and corrosion properties are presented. The occurring rapid solidification results in a fine‐grained austenitic microstructure with mainly homogeneous element distribution, which is investigated by scanning electron microscopy (SEM) combined with energy‐dispersive X‐ray spectroscopy (EDX) and electron backscatter diffraction (EBSD) as well as X‐ray diffraction (XRD). By processing the alloy via SLM, significantly higher strengths under tensile and compressive load in comparison with those for the as‐cast counterpart and a 316L reference steel are achieved. Electrochemical corrosion tests in a simulated body fluid (SBF) indicate a moderate corrosion activity, and a beneficial uniform degradation is shown in immersion tests in SBF. Regarding the envisaged application for vascular implants, SLM‐processed stent prototypes out of the novel alloy are presented and a first functionality test is shown.

16 August 2017 in Materials and Corrosion
Verified
Journal Article
Open access
PDF file
AGA. Gebert
A. Gebert
FKF. Kochta
F. Kochta
AVA. Voß
A. Voß
SOS. Oswald
S. Oswald
MFM. Fernandez‐Barcia
M. Fernandez‐Barcia
JHJulia Kristin Hufenbach
Julia Kristin Hufenbach
Austenitic Fe‐30Mn‐1C (FeMnC) is a prospective biodegradable implant material combining high mechanical integrity with adequate corrosion rates. The fast solidified TWIP alloy, its constituents and 316L stainless steel were electrochemically analysed in various electrolytes at 37 °C under laminar flow. Potentiodynamic polarization tests were conducted in Tris‐buffered simulated body fluid (SBF), in Tris‐buffered saline (TBS) and in 150–0.15 mM NaCl solutions (pH 7.6, 10, 5, 2) to study initial corrosion stages. Active dissolution of FeMnC is revealed in all electrolytes and is discussed on basis of the Fe and Mn behaviour plus is compared to that of 316L. The role of Tris (Tris(hydroxymethyl)aminomethane) as organic buffer for SBFs is critically assessed, particularly with view to the sensitivity of Fe. SEM studies of FeMnC corroded in NaCl revealed preferential dissolution along Mn‐rich grain boundary regions. Static immersion tests of FeMnC in SBF with surface and solution analyses (SEM/EDX, XPS, ICP‐OES) indicated that dissolution processes interfere with the formation of permeable surface coatings comprising hydroxides and salts.

2 June 2015 in Metals
Verified
Journal Article
Open access
PDF file
BSBaran Sarac
Baran Sarac
Daniel SopuDaniel Sopu
Daniel Sopu
EPEunmi Park
Eunmi Park
JHJulia Kristin Hufenbach
Julia Kristin Hufenbach
SOSteffen Oswald
Steffen Oswald
JEJürgen Eckert
Jürgen Eckert
The intrinsic properties of advanced alloy systems can be altered by changing their microstructural features. Here, we present a highly efficient method to produce and characterize structures with systematically-designed pores embedded inside. The fabrication stage involves a combination of photolithography and deep reactive ion etching of a Si template replicated using the concept of thermoplastic forming. Pt- and Zr-based bulk metallic glasses (BMGs) were evaluated through uniaxial tensile test, followed by scanning electron microscope (SEM) fractographic and shear band analysis. Compositional investigation of the fracture surface performed via energy dispersive X-ray spectroscopy (EDX), as well as Auger spectroscopy (AES) shows a moderate amount of interdiffusion (5 at.% maximum) of the constituent elements between the deformed and undeformed regions. Furthermore, length-scale effects on the mechanical behavior of porous BMGs were explored through molecular dynamics (MD) simulations, where shear band formation is observed for a material width of 18 nm.

23 July 2011 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
JHJulia Kristin Hufenbach
Julia Kristin Hufenbach
SKS. Kohlar
S. Kohlar
UKU. Kühn
U. Kühn
LGLars Giebeler
Lars Giebeler
JEJürgen Eckert
Jürgen Eckert