TERESA KWAMBOKA ABUYA

Ms. TERESA KWAMBOKA ABUYA


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TATERESA KWAMBOKA ABUYA
TERESA KWAMBOKA ABUYA
RRRichard Maina Rimiru
Richard Maina Rimiru
GOGeorge Onyango Okeyo
George Onyango Okeyo
Denoising computed tomography (CT) medical images is crucial in preserving information and restoring images contaminated with noise. Standard filters have extensively been used for noise removal and fine details’ preservation. During the transmission of medical images, noise degrades the visibility of anatomical structures and subtle abnormalities, making it difficult for radiologists to accurately diagnose and interpret medical conditions. In recent studies, an optimum denoising filter using the wavelet threshold and deep-CNN was used to eliminate Gaussian noise in CT images using the image quality index (IQI) and peak signal-to-noise ratio (PSNR). Although the results were better than those with traditional techniques, the performance resulted in a loss of clarity and fine details’ preservation that rendered the CT images unsuitable. To address these challenges, this paper focuses on eliminating noise in CT scan images corrupted with additive Gaussian blur noise (AGBN) using an ensemble approach that integrates anisotropic Gaussian filter (AGF) and wavelet transform with a deep learning denoising convolutional neural network (DnCNN). First, the noisy image is denoised by AGF and Haar wavelet transform as preprocessing operations to eliminate AGBN. The DnCNN is then combined with AGF and wavelet for post-processing operation to eliminate the rest of the noises. Specifically, we used AGF due to its adaptability to edge orientation and directional information, which prevents blurring along edges for non-uniform noise distribution. Denoised images are evaluated using PSNR, mean squared error (MSE), and the structural similarity index measure (SSIM). Results revealed that the average PSNR value of the proposed ensemble approach is 28.28, and the average computational time is 0.01666 s. The implication is that the MSE between the original and reconstructed images is very low, implying that the image is restored correctly. Since the SSIM values are between 0 and 1.0, 1.0 perfectly matches the reconstructed image with the original image. In addition, the SSIM values at 1.0 or near 1.0 implicitly reveal a remarkable structural similarity between the denoised CT image and the original image. Compared to other techniques, the proposed ensemble approach has demonstrated exceptional performance in maintaining the quality of the image and fine details’ preservation.

3 April 2025 in Signals
Verified
Journal Article
Open access
PDF file
TATERESA KWAMBOKA ABUYA
TERESA KWAMBOKA ABUYA
RRRichard Rimiru
Richard Rimiru
GOGeorge Okeyo
George Okeyo
Medical imaging is crucial for disease diagnosis, but noise in CT and MRI scans can obscure critical details, making accurate diagnosis challenging. Traditional denoising methods and deep learning techniques often produce overly smooth images that lack vital diagnostic information. GAN-based approaches also struggle to balance noise removal and content preservation. Existing research has not explored tumor detection after image denoising; instead, it has concentrated on content and noise learning. To address these challenges, this study proposes the Adversarial Content–Noise Complementary Learning (ACNCL) model, which enhances image denoising and tumor detection. Unlike conventional methods focusing solely on content or noise learning, ACNCL simultaneously learns both through dual predictors, ensuring the complementary reconstruction of high-quality images. The model integrates multiple denoising techniques (DnCNN, U-Net, DenseNet, CA-AGF, and DWT) within a GAN framework, using PatchGAN as a local discriminator to preserve fine image textures. The ACNCL separates anatomical details and noise into distinct pathways, ensuring stable noise reduction while maintaining structural integrity. Evaluated on CT and MRI datasets, ACNCL demonstrated exceptional performance compared to traditional models both qualitatively and quantitatively. It exhibited strong generalization across datasets, improving medical image clarity and enabling earlier tumor detection. These findings highlight ACNCL’s potential to enhance diagnostic accuracy and support improved clinical decision-making.