This paper introduces a complete DC-AC conversion system fed by photovoltaic (PV) energy. The system consists of N PV panels, N DC-DC boost converters, N cascaded H-bridge inverters, a DC-link composed of N capacitors and an LCL filter. This work aims at reaching threefold control objectives: i) Extracting the available maximum power by regulating the voltages across the PV panels, ii) Ensuring a unitary power factor, iii) Regulating the DC-link voltage to a desired reference. To achieve the mentioned objectives, a multi-loop regulator is designed. The PV panels are individually controlled to track the maximum power point in order to efficiently operate at either the same or different varying climatic conditions without failures. In addition to the maximum power point tracking (MPPT) controller, two cascaded loops guaranteeing a satisfactory power factor and DC-link voltage regulation are developed. The nonlinear backstepping approach combined with Lyapunov theory are used based on the averaged model for the synthesis of the multi-loop controller. The performance of the studied system is tested via MATLAB / SimPowerSystems environment. The obtained simulation results prove that the proposed controller meets its objectives and demonstrate the efficiency of the chosen control strategy under faulty conditions.
3 September 2021 in Journal of Control, Automation and Electrical Systems
This paper deals with the control development of a wind energy conversion system (WECS) interfaced to a utility grid by using a doubly fed induction generator (DFIG), a back-to-back (B2B) converter and an RL filter for optimal power extraction. The aim was to design a sensorless controller to improve the system reliability and to simultaneously achieve the regulation of the generator speed, reactive power and DC-link voltage. The proposed global control scheme combines: (i) a high-gain observer employed to estimate the generator speed and the mechanical torque, usually regarded as accessible, (ii) a sensorless MPPT block developed to provide optimal generator speed reference, which is designed on the basis of the mechanical observer and a polynomial wind-speed estimator and (iii) a finite-time controller (FTC) applied to the B2B converter to meet the output reference’s tracking objectives in a short predefined finite time by using the backstepping and Lyapunov approaches. The proposed controller performance is formally analysed, and its capabilities are verified by numerical simulations using a 2 MW DFIG wind turbine (WT) under different operating conditions.
This paper deals with the design and implementation of a robust control approach for grid-tied PV systems. The main controller’s objectives are to inject the maximum available power to the grid, whilst guaranteeing power quality even under faulty conditions. To this end, a multi-loop regulator is designed for the Cascaded H-Bridge Multilevel Inverters (CHBMIs) by combining a sliding mode control strategy for maximum power point tracking and a Lyapunov approach for Power Factor Correction (PFC). Validation of the proposed approach using Matlab/ SimPowerSimscape environment confirmed the ability of the proposed approach to successfully accomplish its objectives in terms of references tracking and regulation under both matching and mismatching irradiation levels as well as faulty modes stemming from the photovoltaic (PV) panels and/or the dc-dc converters. Additionally, the proposed approach was shown to outperform conventional approaches and enable the continuous operation of the PV system under various failure modes affecting multiple PV panels and/or their associated dc-dc boost converters.
1 June 2021 in International Journal of Power Electronics and Drive Systems (IJPEDS)
This article addresses the problem of controlling an overall wind energy conversion system (WECS) formed by a wind turbine connected to the grid via a doubly fed introduction generator (DFIG) and an AC/DC/AC converter. The main control objectives are fourfold: (i) designing an output feedback speed controller that makes the DFIG rotate at the optimal value delivered by the MPPT strategy, (ii) controlling the stator reactive power so as to be null, (iii) guaranteeing the DC-link voltage in the grid side converter to be at a given constant value, (iv) ensuring a unitary power factor. A high gain observer is synthesized, in order to provide estimated values of the mechanical variables. To achieve the control objectives, a sliding mode controller involving the mechanical observer is designed. The performance of the system configuration based on the 2MW-DFIG with the proposed controller is evaluated by a numerical simulation under a realistic wind profile using MATLAB/SIMULINK/SimPowerSystems environment.