Issah Babatunde Majeed

Mr. Issah Babatunde Majeed

Electrical and Electronic Engineering, Accra Technical University, Accra, Greater Accra, Ghana
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
IMIssah Babatunde Majeed
Issah Babatunde Majeed
Nnamdi NwuluNnamdi Nwulu
Nnamdi Nwulu
Modern low-voltage distribution systems necessitate solar photovoltaic (PV) penetration. One of the primary concerns with this grid-connected PV system is overloading due to reverse power flow, which degrades the life of distribution transformers. This study investigates transformer overload issues due to reverse power flow in a low-voltage network with high PV penetration. A simulation model of a real urban electricity company in Ghana is investigated against various PV penetration levels by load flows with ETAP software. The impact of reverse power flow on the radial network transformer loadings is examined for high PV penetrations. Using the least squares method, simulation results are modelled in Excel software. Transformer backflow limitations are determined by correlating operating loads with PV penetration. At high PV penetration, the models predict reverse power flow into the transformer. Interpolations from the correlation models show transformer backflow operating limits of 78.04 kVA and 24.77% at the threshold of reverse power flow. These limits correspond to a maximum PV penetration limit of 88.30%. In low-voltage networks with high PV penetration; therefore, planners should consider transformer overload limits caused by reverse power flow, which degrades transformer life. This helps select control schemes near substation transformers to limit reverse power flow.

5 May 2023 in IEEE Access
Verified
Journal Article
Open access
IMIssah Babatunde Majeed
Issah Babatunde Majeed
Nnamdi NwuluNnamdi Nwulu
Nnamdi Nwulu
Distributed generation has enhanced power production in recent times. Due to their benefits, Ghana is interested in grid-tied solar Photo Voltaic (PV) systems. Despite the benefits, solar PV integration studies in Ghana have not advanced. This study examines reverse power flow (RPF) due to solar PV in Low Voltage (LV) network branches. The methodology uses a modified IEEE European test network and an Electricity Company of Ghana (ECG) LV network. ETAP software is used to simulate the two solar PV integrated LV networks, and the obtained data is used to formulate correlation models of solar PV penetration and key network parameters in Excel. Model results estimate the RPF critical values for the modified IEEE European test network and the ECG LV network as 7.36 kW and 7.44 kW, respectively. The RPF values are obtained at maximum penetration depths of 62.6% and 69.8% respectively. At maximum penetration levels, predicted line loadings are 6.42% and 7.28% respectively. Further analysis reveals branch-transformer RPF margins of 26.8% and 23.1% in the modified IEEE European test network and the ECG LV network respectively. The results are essential for establishing pre-determined settings to safeguard LV network branches and transformers from overload due to RPF.

14 October 2024 in IEEE Access
Verified
Journal Article
Open access
IMIssah Babatunde Majeed
Issah Babatunde Majeed
Nnamdi NwuluNnamdi Nwulu
Nnamdi Nwulu
The impact of solar photovoltaic (PV) systems on power distribution systems has attracted significant research interest. However, integrating large-scale PV systems into low-voltage (LV) networks poses several technical challenges. Hence, penetration limits and hosting capacity are essential for high PV penetration LV networks. This study proposes a novel perspective to develop a technical planning framework for large-scale PV integration through steady-state analysis in LV networks. The objective is to determine global hosting capacity by introducing a novel harmonization concept of derived penetration depth. The methodology, tested on a modified IEEE European network, combines simulation-based optimization and statistical methods. ETAP software runs an optimal power flow on the test network to maximize PV power generation at three successive bus locations, aimed at improving network bus voltages based on network-wide and location-based constraints. The simulation results are used to formulate global hosting capacity models using an Excel spreadsheet. These models estimate the global hosting capacities of 0.0334 MW for bus 74, 0.0337 MW for bus 55, and 0.0335 MW for bus 24. The proposed global hosting capacity concept can aid system planners and grid operators make informed decisions by considering network-wide and location-based constraints when integrating PV systems into LV networks.