Piezo-driven precision positioning platforms with large stroke are greatly demanded in both scientific research and industrial applications. Although various principles have been proposed to design piezo-driven positioning platforms, the problem of backward motion commonly exists, greatly hindering their applications. To suppress the backward motion, in this paper, an idea by generating a forward frictional force to balance the reversed frictional force was proposed. Correspondingly, a specific arc-shape flexure hinge was designed to generate the forward frictional force via its elastic recovery. To verify the feasibility of the proposed idea, a positioning platform with alterable initial gap between contact surfaces was designed by the parasitic motion principle (PMP). By measuring the output displacement under various initial gaps, a critical initial gap was identified, at which the positioning platform could output stepping displacement without backward motion. Under this critical initial gap, effects of driving voltage and frequency on the backward motion were further investigated. In addition, the natural frequency and loading capacity of the positioning platform were tested. This study confirms that using PMP, it is feasible to design piezo-driven positioning platforms with completely suppressed backward motion, which would enhance the applications of the PMP and PMP positioning platforms.
A linear piezoelectric actuator based on the stick-slip principle is presented and tested in this paper. With the help of changeable vertical preload force flexure hinge, the designed linear actuator can achieve both large travel stick-slip motion and high-resolution stepping displacement. The developed actuator mainly consists of a bridge-type flexure hinge mechanism, a compound parallelogram flexure hinge mechanism, and two piezoelectric stacks. The mechanical structure and motion principle of the linear actuator were illustrated, and the finite element method (FEM) is adopted. An optimal parametric study of the flexure hinge is performed by a finite element analysis-based response surface methodology. In order to investigate the actuator’s working performance, a prototype was manufactured and a series of experiments were carried out. The results indicate that the maximum motion speed is about 3.27 mm/s and the minimum stepping displacement is 0.29 μm. Finally, a vibration test was carried out to obtain the first natural frequency of the actuator, and an in situ observation was conducted to investigate actuator’s stick-slip working condition. The experimental results confirm the feasibility of the proposed actuator, and the motion speed and displacement are both improved compared with the traditional stick-slip motion actuator.
Miniaturization precision positioning platforms are needed for in situ nanomechanical test applications. This paper proposes a compact precision positioning platform integrating strain gauges and the piezoactuator. Effects of geometric parameters of two parallel plates on Von Mises stress distribution as well as static and dynamic characteristics of the platform were studied by the finite element method. Results of the calibration experiment indicate that the strain gauge sensor has good linearity and its sensitivity is about 0.0468 mV/μm. A closed-loop control system was established to solve the problem of nonlinearity of the platform. Experimental results demonstrate that for the displacement control process, both the displacement increasing portion and the decreasing portion have good linearity, verifying that the control system is available. The developed platform has a compact structure but can realize displacement measurement with the embedded strain gauges, which is useful for the closed-loop control and structure miniaturization of piezo devices. It has potential applications in nanoindentation and nanoscratch tests, especially in the field of in situ nanomechanical testing which requires compact structures.
1 December 2017 in Journal of Mechanics in Medicine and Biology
In reality, nanoindentation test is an efficient technique for probing the mechanical properties of biological tissue that soaked in the liquid media to keep the bioactivity. However, the effects of flotage imposed on the indenter will lead to inaccuracy when calculating mechanical properties (for instance, elastic modulus and hardness) by using depth-sensing nanoindentation. In this paper, the effects of flotage on the nanoindentation results of cortical bone were investigated by finite element analysis (FEA) simulation. Comparisons of nanoindentation simulation results of bone samples with and without being soaked in the liquid media were carried out. Conclusions show that the difference of load-displacement curves in the case of soaking sample and without soaking sample conditions varies widely based on the change of indentation depth. In other words, the nanoindentation measurements in liquid media will cause significant error in the calculated Young’s modules and hardness due to the flotage. By taking into account the effect of flotage, these errors are particularly important to the accurate biomechanics characterization of biological samples.