X-ray transmittance and backscatter imaging are important methods for detecting drugs and plastic explosives in the security-inspection field. In this study, we developed an analytical model based on Geant4 toolkit and verified it by measuring the energy spectrum and backscatter images. According to the model, we analyzed the imaging contrasts to detect concealed contrabands. The results show that the backscatter contrasts are significantly better than those of the transmission, especially in thinner organic materials. However, for shelters with strong absorption and scattering, the gaps become smaller. In addition, the variations in the contrasts with thickness appear to linearly increase in the transmittance imaging and nonlinearly grow until saturation in the backscatter imaging. Compared with traditional methods, our model, which is more accurate and complete, employs energetically distributed X-rays, instead of monochromatic X-rays, and involves multiple scattering effects. By using this method, we cannot only calculate and analyze the image characteristics of large amounts of contrabands in various system structures but also design and optimize instruments specially used to detect drugs and explosives.
X-ray security inspection processes have a low degree of automation, long detection times, and are subject to misjudgment due to occlusion. To address these problems, this paper proposes a multi-objective intelligent recognition method for X-ray images based on the YOLO deep learning network and an optimized transformer structure (YOLO-T). We also construct the GDXray-Expanded X-ray detection dataset, which contains multiple types of dangerous goods. Using this dataset, we evaluated several versions of the YOLO deep learning network model and compared the results to those of the proposed YOLO-T model. The proposed YOLO-T method demonstrated higher accuracy for multitarget and hidden-target detection tasks. On the GDXray-Expanded dataset, the maximum mAP of the proposed YOLO-T model was 97.73%, which is 7.66%, 16.47%, and 7.11% higher than that obtained by the YOLO v2, YOLO v3, and YOLO v4 models, respectively. Thus, we believe that the proposed YOLO-T network has good application prospects in X-ray security inspection technologies. In all kinds of security detection scenarios using X-ray security detectors, the model proposed in this paper can quickly and accurately identify dangerous goods, which has broad application value.
1 October 2022 in Review of Scientific Instruments
Here, we describe a flat-field-response, four-channel x-ray imaging instrument developed to study hotspot asymmetries in inertial-confinement fusion experiments. We discuss the details of its design and optical characterization, the diagnostic deployment of the device, and experiments with it. We achieved a spatial-response flatness better than ∼8.4% within a ±200 µm field of view (FOV), with a spatial resolution of ∼4 µm at the center of the FOV. We used the system to characterize the low-order asymmetry of the implosion hotspot, and we obtained improved results after adjustments to improve the irradiation symmetry. Due to the flat-field-response characteristic, the versatile instrument also has the potential to be applied to diagnostics for the hotspot electron temperature and the Rayleigh–Taylor instability.
The diagnostic demand of hot-spot intensity distribution in laser inertial confinement fusion experiment has motivated quantitative measurement experiment to give the response efficiency of grazing incidence system to improve the accuracy of the diagnosis. In our study, a full-aperture intensity response measurement method is proposed, which is based on pinhole-scanning field of view (FOV) to obtain the response efficiency of grazing incidence system. The method is highly repeatable and enables response efficiency measurements over the full FOV with acceptable accuracy. A silicon positive-intrinsic-negative detector with an energy response range of 1.5 to 30 keV is used to directly detect the input and output spectrum. The response efficiency of a single-channel aspheric Kirkpatrick–Baez (KB) microscope coated with W/Si is obtained under the FOV of ±150 μm. The response efficiency of center FOV of the KB system is measured to be 2.52E-7 sr. The value is promising, as it shows a 6.6% maximum deviation from the theoretical value at center FOV, with a global uncertainty of 7.4%.
1 September 2022 in Review of Scientific Instruments
High-precision x-ray imaging diagnostics of hotspot at the stagnation stage are essential for regulating implosion asymmetry and retrieving physical implosion parameters. With regard to 10–20 keV energy band imaging, existing diagnostic instruments such as Kirkpatrick–Baez microscopes and pinhole cameras are insufficient in terms of spatial resolution and collection efficiency. The situation is even worse when high-speed, time-resolved imaging diagnostics are performed by coupling framing cameras or line-of-sight imagers. This article presents the basic principles and optical system design of a 17.48 keV modified Wolter x-ray microscope, to resolve the problems encountered in high-energy imaging diagnostics. The proposed optical configuration offers a better spatial resolution, greater depth of field, and preliminary compliance with the requirements of high precision optical processing techniques. The spatial resolution is better than 1 µm in a field range ±150 µm, and is better than 3 µm in a total field of view ∼408 µm in diameter. The geometric solid angle is calculated as 3.0 × 10−5 sr and is estimated to be 1.2 × 10−6 sr, considering the reflectivity of the double mirrors. The proposed microscope is expected to effectively improve spatial resolution and signal-to-noise ratio for high-energy imaging diagnostics.
Energy-dispersive X-ray diffraction (EDXRD) is a promising technique for detecting drugs and explosives in security inspections. In this study, we proposed an EDXRD structure with a spiral-array of detectors that can be used for the detection of thick objects. The detectors are configured to share the same diffraction angle, and the detection area of the system is multiplied along the optical axis. Based on the spiral-array structure, an experimental system with 5 CdTe detectors was established. Experimental results demonstrate that the accurate data can be acquired at different positions within the 250-mm detection area, and the data measured by 5 detectors have a good consistency. This work may provide a new and commercial method for the detection of thick luggage in the field of security inspection.