The diagnostic demand of hot-spot intensity distribution in laser inertial confinement fusion experiment has motivated quantitative measurement experiment to give the response efficiency of grazing incidence system to improve the accuracy of the diagnosis. In our study, a full-aperture intensity response measurement method is proposed, which is based on pinhole-scanning field of view (FOV) to obtain the response efficiency of grazing incidence system. The method is highly repeatable and enables response efficiency measurements over the full FOV with acceptable accuracy. A silicon positive-intrinsic-negative detector with an energy response range of 1.5 to 30 keV is used to directly detect the input and output spectrum. The response efficiency of a single-channel aspheric Kirkpatrick–Baez (KB) microscope coated with W/Si is obtained under the FOV of ±150 μm. The response efficiency of center FOV of the KB system is measured to be 2.52E-7 sr. The value is promising, as it shows a 6.6% maximum deviation from the theoretical value at center FOV, with a global uncertainty of 7.4%.
1 October 2022 in Review of Scientific Instruments
Here, we describe a flat-field-response, four-channel x-ray imaging instrument developed to study hotspot asymmetries in inertial-confinement fusion experiments. We discuss the details of its design and optical characterization, the diagnostic deployment of the device, and experiments with it. We achieved a spatial-response flatness better than ∼8.4% within a ±200 µm field of view (FOV), with a spatial resolution of ∼4 µm at the center of the FOV. We used the system to characterize the low-order asymmetry of the implosion hotspot, and we obtained improved results after adjustments to improve the irradiation symmetry. Due to the flat-field-response characteristic, the versatile instrument also has the potential to be applied to diagnostics for the hotspot electron temperature and the Rayleigh–Taylor instability.
The Kirkpatrick–Baez (KB) microscope is an effective instrument for x-ray imaging of hot spot. However, the non-uniform distribution of response efficiency in the field of view is a drawback of the KB microscope. A more accurate hot spot image requires the correction of the measured image by combining the hot spot position and the response efficiency distribution. Here, we describe a method to locate the position of the hot spot in the field of view during hot spot imaging with a KB microscope. The position of the hot spot in the field of view can be obtained by measuring the grazing incidence angle change during hot spot imaging. In the experiment of hot spot self-emission imaging with a four-channel KB microscope, the location of the hot spot with an accuracy of 15 μm was realized, and the intensity corrected hot spot image was obtained. This will solve the problem of the non-uniform distribution of the response efficiency of the KB microscope and enable quantitative measurement of hot spot radiation intensity.
The representation of the higher-mode signatures of the hot spot and the fine-scale features of Rayleigh–Taylor (RT) instability requires the diagnostic system to achieve a spatial resolution of 1–3 µm in inertial confinement fusion experiments. The former’s demand has prompted the present proposal of an advanced Kirkpatrick–Baez (KB) microscope with large magnification and high resolution. We have employed a coaxial confocal optical configuration, combining elliptical concave mirrors and hyperbolic convex mirrors, to achieve the ideal imaging performance. Such a configuration has the advantage of increasing the system’s magnification without decreasing the object distance. This microscope is expected to solve the current problem regarding the constraint of the system’s integrated resolution by the detector’s resolution bottleneck. The structural features and optical design of the proposed KB microscope are described in detail, and a preliminary assessment of its off-axis aberration and spectral response characteristics is presented. A simulation model based on ray tracing and physical processes is used to evaluate the mirror mounting tolerance limit and the microscope’s ability to resolve RT instability structures. Our results demonstrated that the system can achieve a theoretical resolution of 25% increase compared to conventional KB systems.
The measurement of the electron temperature distribution of hotspot requires bremsstrahlung imaging with both spectral resolution and spatial resolution. The Kirkpatrick–Baez (KB) microscope is an important diagnostic device in inertial confinement fusion experiments, which can realize high spatial resolution imaging of multi-energy. However, conventional KB microscopes face a fundamental trade-off between achieving a quasi-monoenergetic response and maintaining uniform efficiency across the field of view. This inherent limitation leads to difficulties in efficiency calibration and can introduce distortion in hotspot images, thereby preventing their effective application in the quantitative measurement of hotspot radiation intensity. This paper proposes a four-energy-point KB microscope with a self-adjusting spectral response, in which the response energies adapt to the field-of-view position. The design simultaneously achieves a quasi-monoenergetic response and a uniform efficiency distribution, thereby mitigating hot-spot image distortion and simplifying efficiency calibration. Each channel of this microscope achieves a spectral resolution of ΔE/E ∼ 10%, and the efficiency uniformity (relative standard deviation: ση/η̄) within the ±150 μm field of view is 6.27%–9.63%. The spatial resolution at the center of the field of view is better than 5 μm. We deployed this microscope for implosion hotspot imaging, successfully acquiring images at four distinct energy points. These images are suitable for diagnosing hotspot electron temperature.
High-energy X-ray diagnostic systems are crucial for understanding hotspot high-density area asymmetry, fuel mixing, and other phenomena in inertial confinement fusion. To meet the demand for hotspot electron temperature measurements, we developed a high-energy dual-channel Kirkpatrick–Baez microscope. This microscope is characterized by a dual high-energy response and high spatial resolution, enabling the observation of fine structures in high-density regions of a hotspot. Spectral drift was effectively mitigated by optimizing the grazing incidence angle, and the spatial and spectral domains were coupled through experimental alignment. Herein, we describe the optical design of the proposed microscope. Furthermore, we performed simulations and backlight imaging to validate the performance of the proposed system. The results show that the spatial resolution was better than 3 μm in the center and better than 6.5 μm in a field of view of 300 μm. The spectral response efficiencies at 11.4 and 17.48 keV were 7.41 × 10−8 and 5.77 × 10−8 sr, which deviate from the theoretical values by 3.01% and 6.79%, respectively.