Lichun Zhang

Dr. Lichun Zhang

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2014 in Biomacromolecules
Verified
Journal Article
Open access
BTBradley W. Tuft
Bradley W. Tuft
LZLichun Zhang
Lichun Zhang
LXLinjing Xu
Linjing Xu
AHAustin Hangartner
Austin Hangartner
BLBraden Leigh
Braden Leigh
CGC. Allan Guymon
C. Allan Guymon
The ability to direct neurite growth into a close proximity of stimulating elements of a neural prosthesis, such as a retinal or cochlear implant (CI), may enhance device performance and overcome current spatial signal resolution barriers. In this work, spiral ganglion neurons (SGNs), which are the target neurons to be stimulated by CIs, were cultured on photopolymerized micropatterns with varied matrix stiffnesses to determine the effect of rigidity on neurite alignment to physical cues. Micropatterns were generated on methacrylate thin film surfaces in a simple, rapid photopolymerization step by photomasking the prepolymer formulation with parallel line–space gratings. Two methacrylate series, a nonpolar HMA-co-HDDMA series and a polar PEGDMA-co-EGDMA series, with significantly different surface wetting properties were evaluated. Equivalent pattern periodicity was maintained across each methacrylate series based on photomask band spacing, and the feature amplitude was tuned to a depth of 2 μm amplitude for all compositions using the temporal control afforded by the UV curing methodology. The surface morphology was characterized by scanning electron microscopy and white light interferometry. All micropatterned films adsorb similar amounts of laminin from solution, and no significant difference in SGN survival was observed when the substrate compositions were compared. SGN neurite alignment significantly increases with increasing material modulus for both methacrylate series. Interestingly, SGN neurites respond to material stiffness cues that are orders of magnitude higher (GPa) than what is typically ascribed to neural environments (kPa). The ability to understand neurite response to engineered physical cues and mechanical properties such as matrix stiffness will allow the development of advanced biomaterials that direct de novo neurite growth to address the spatial signal resolution limitations of current neural prosthetics.

1 July 2018 in Hearing Research
Verified
Journal Article
Closed access
LZLichun Zhang
Lichun Zhang
SESina Engler
Sina Engler
LKLena Koepcke
Lena Koepcke
FSFriederike Steenken
Friederike Steenken
CKChristine Köppl
Christine Köppl

7 September 2022 in Medical Image Analysis
Verified
Journal Article
Closed access
YPYaopeng Peng
Yaopeng Peng
HZHao Zheng
Hao Zheng
PLPeixian Liang
Peixian Liang
LZLichun Zhang
Lichun Zhang
FZFahim Zaman
Fahim Zaman
DCDanny Z. Chen
Danny Z. Chen

24 July 2015 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
LZLichun Zhang
Lichun Zhang
NGNa Gao
Na Gao
YYYanbo Yin
Yanbo Yin
LYLin Yang
Lin Yang
YXYouzhou Xie
Youzhou Xie
ZTZhang Tiainyu
Zhang Tiainyu

6 September 2024 in Otology & Neurotology
Verified
Journal Article
Closed access
LZLichun Zhang
Lichun Zhang
FSFlorian Herrmann Schmidt
Florian Herrmann Schmidt
DCDaniel Cantré
Daniel Cantré
RBRobert Brenzel
Robert Brenzel
KEKarsten Ehrt
Karsten Ehrt
RMRobert Mlynski
Robert Mlynski
Objective: The current study aims to investigate whether objective measurements of the cochlear nerve (CN), derived from preoperative MRI images, correlate with postoperative speech perception in CI patients. Study Design: Retrospective cohort study. Setting: University Medical Center, tertiary academic referral center. Patients: Patients undergoing a cochlear implant surgery including MED-EL (Synchrony 2, FLEX electrode series; MED-EL, Innsbruck, Austria) Cochlear (slim straight electrodes; Cochlear Ltd., Sydney, Australia), Advanced Bionics (HiRes Ultra 3D CI, HiFocus SlimJ electrodes; Sonova, Zürich, Switzerland), and Oticon (Neuro Zti EVO; Oticon A/S, Smørum, Denmark) between 2020 and 2023. Intervention: Preoperative MRI images were utilized to measure the volume of the modiolus (VM), the cross-sectional areas of the CN (ACN), and for normalization, the area of the facial nerve (AFN) and the area of the internal ear canal (AIEC). Postoperative speech perceptions were assessed through word recognition scores (WRS) at several stages following the first fitting (FF) of the CI processor: immediately after FF, 1 month, 3 months, and 6 months after FF. Main Outcome Measures: Sixty-eight patients were enrolled in this study. A statistically significant positive correlation between the ratio between ACN and AFN (ACN/AFN) and WRS FF was identified ( R = 0.36, p < 0.003). However, this correlation disappeared in subsequent follow-up tests. Moreover, upon grouping patients based on their degree of asymmetrical hearing loss, it was observed that the correlation was primarily driven by patients with moderate to severe asymmetrical hearing loss (AHLm) on the contralateral side ( R = 0.62, p = 0.0003). Conclusion: The present results suggest that assessing the size of the CN through MRI has limited predictive utility for postoperative speech perceptions during CI consultations. This limitation seems to be particularly relevant for AHLm patients and is confined to the initial activation period.

16 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FSFlorian Schmidt
Florian Schmidt
THThomas Hocke
Thomas Hocke
LZLichun Zhang
Lichun Zhang
WGWilma Großmann
Wilma Großmann
RMRobert Mlynski
Robert Mlynski
Among hearing aid (HA) users, there is a considerable variability in word recognition scores (WRSs). This variability is most pronounced among individuals with moderately severe to severe hearing loss. The variability cannot be adequately explained by factors such as pure-tone audiogram, audiogram type or age. This prospective study was designed to investigate the relationship between tone decay (TD) and WRS in a group of HA users with corresponding pure-tone hearing loss. The study population included 22 patients with hearing loss between 50 and 80 dB HL. Aided WRS, unaided WRS and TD were assessed for both ears. TD was found to be frequency-dependent. TD and WRS were correlated, with up to R = −0.66. The TD test was revealed to be a feasible method for explaining variability in WRS among HA users with hearing loss below 80 dB. This may contribute to improved differential diagnostics. The TD test may thus offer a better understanding of the limitations of HA use in the context of cochlear implant candidacy assessment for HA users.