Graphene films were exposed to low-pressure capacitively coupled (E-mode) and inductively coupled (H-mode) argon radio frequency plasmas to investigate damage formation by very-low-energy ion irradiation. In the H-mode, plasma parameters were assessed by a Langmuir probe and plasma sampling mass spectrometry to determine the conditions of fixed ion fluence but with different average ion energies. The populations of argon metastable and resonant argon atoms were also measured by optical absorption spectroscopy to determine their contribution to the total energy flux during plasma treatment. In the H-mode, in which plasma-graphene interactions are dominated by ion irradiation effects, Raman spectroscopy reveals a significant rise in the D/G ratio and full width at half maximum of the G peak as well as the onset of graphene amorphization, even at very low ion energies (between 7 and 13 eV). In the E-mode characterized by comparable ion energy but much lower ion density, significant damage is also observed, a feature ascribed to the additional energy flux linked to the de-excitation of metastable argon species on the graphene surface.
4 December 2020 in npj 2D Materials and Applications
Hyperspectral Raman IMAging (RIMA) is used to study spatially inhomogeneous polycrystalline monolayer graphene films grown by chemical vapor deposition. Based on principal component analysis clustering, distinct regions are differentiated and probed after subsequent exposures to the late afterglow of a microwave nitrogen plasma at a reduced pressure of 6 Torr (800 Pa). The 90 × 90 µm2RIMA mapping shows differentiation between graphene domains (GDs), grain boundaries (GBs), as well as contaminants adsorbed over and under the graphene layer. Through an analysis of a few relevant band parameters, the mapping further provides a statistical assessment of damage, strain, and doping levels in plasma-treated graphene. It is found that GBs exhibit lower levels of damage and N-incorporation than GDs. The selectivity at GBs is ascribed to (i) a low migration barrier of C adatoms compared to N-adatoms and vacancies and (ii) an anisotropic transport of C adatoms along GBs, which enhances adatom-vacancy recombination at GBs. This preferential self-healing at GBs of plasma-induced damage ensures selective incorporation of N-dopants at plasma-generated defect sites within GDs. This surprising selectivity vanishes, however, as the graphene approaches an amorphous state.
Raman spectroscopy provides rich optical signals that can be used, after data analysis, to assess if a graphene layer is pristine, doped, damaged, functionalized, or stressed. The area being probed by a conventional Raman spectrometer is, however, limited to the size of the laser beam (∼1 µm); hence, detailed mapping of inhomogeneities in a graphene sample requires slow and sequential acquisition of a Raman spectrum at each pixel. Studies of physical and chemical processes on polycrystalline and heterogeneous graphene films require more advanced hyperspectral Raman capable of fast imaging at a high spatial resolution over hundreds of microns. Here, we compare the capacity of two different Raman imaging schemes (scanning and global) to probe graphene films modified by a low-pressure plasma treatment and present an analysis method providing assessments of the surface properties at local defects, grain boundaries, and other heterogeneities. By comparing statistically initial and plasma-treated regions of graphene, we highlight the presence of inhomogeneities after plasma treatment linked to the initial state of the graphene surface. These results provided statistical results on the correlation between the graphene initial state and the corresponding graphene–plasma interaction. This work further demonstrates the potential use of global hyperspectral Raman imaging with advanced Raman spectra analysis to study graphene physics and chemistry on a scale of hundreds of microns.
Pulsed gas injection in a plasma can affect many fundamentals, including electron heating and losses. The case of an asymmetric RF magnetron plasma with a pulsed argon injection is analyzed by optical emission spectroscopy of argon 2p-to-1s transitions coupled with collisional-radiative modeling. For a fully detailed population model of argon 2p levels accounting for direct and stepwise electron-impact excitation in optically thick conditions, a rapid decrease in the electron temperature, Te, is observed during each gas injection with the sudden pressure rise. The opposite trend, with unrealistic Te values before and after each pulse, is observed for analysis based on simple corona models, thus emphasizing the importance of stepwise excitation processes and radiation trapping. Time-resolved electron temperature variations are directly linked to the operating parameters of the pulsed gas injection, in particular the injection frequency. Based on the complete set of data, it is shown that the instantaneous electron temperature monotonously decreases with increasing pressure, with values consistent with those expected for plasmas in which charged species are produced by electron-impact ionization of ground state argon atoms and lost by diffusion and recombination on plasma reactor walls.